Specifications

CM907 CHRONOTHERM
EN0H 8547 UK07 R3 09/06 6
DIMENSIONS
LOCATION
The CM907 thermostat is the control element of the heating /
cooling system and, therefore, MUST be located in a position
with good air circulation, at average room temperature and
on an inside wall 1.5 metres, above the floor level. Do not
position the CM907 thermostat near sources of heat
(radiators, hot air vents, TV or lights), near doors or windows,
or in direct sunlight.
MOUNTING
The CM907 thermostat can be mounted directly on the wall
surface or on an electrical wallbox.
WIRING
The CM907 thermostat is designed for fixed wiring only and
must be installed in accordance with the latest l.E.E.
regulations. Ensure the wiring connection to the supply is via
a fuse rated at no more than 8 amps and a Class "A" switch
(having contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning
installation
INSTALLATION