Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Model: CL48PM Power rating: 130 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C.
QUICK START GUIDE Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION PAGE THANK YOU .................................................................. ............................................
THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler.
USER TIPS Energy efficient, No compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room.
USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your cooler runs on 230 Volt AC, 50 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check that it is in good condition. • DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance.
SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as this will overload and damage the motor.
PARTS DESCRIPTION 16 1 9 2 14 3 10 13 4 8 11 15 5 6 12 1 2 3 4 5 6 7 8 Manual Water / Ice Inlet Handle Left Honeycomb Panel Lever for Horizontal Louvers Water Tank Casters Horizontal Louvers Water Level Indicator 7 9 Mechanical Control Panel 10 Right Honeycomb Panel 11 Continuous Water Inlet 12 Water Drain Plug 13 Back Honeycomb Panel 14 Power Cord & Plug 15 Rear Grill Removal Screws 16 Water Fill Door 7
USE & OPERATION CONTROL PANEL NOTE: Speed control may be marked as High / Med / Low in certain units.
USE & OPERATION CONTROL KNOBS 0 3 2 1 SPEED / ON - OFF Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 for High. To switch the unit OFF, turn the SPEED to “0”. SPEED HORIZONTAL LOUVERS Manually adjust the horizontal louvers to change vertical airflow. COOL OFF ON SWING Vertical Louvers Turn the SWING knob to 'ON'. The louvers will begin to move from right to left automatically.
USE & OPERATION CAUTION Unplug from power when refilling. FILLING WATER Water can be filled into the air cooler by: Water / Ice compartment (Manual Refill) Water / ice can be put into the tank though the top opening. There is a hole for water to flow into the tank. Continuous water supply (Auto Refill) Connect a garden hose to the continuous water supply inlet.
USE & OPERATION FILLING WATER (CONTINUOUS WATER SUPPLY CONNECTION) Connect water pipe to the continuous water supply connector located on the lower left side panel. Secure the connector with the pipe so that there is no leakage and turn on the water supply. With the help of the water auto-refill mechanism, water inside the tank will refill automatically. Everytime the water comes below the minimum level, the water float valve will detect it and will start the water flow inside the tank.
CLEANING & MAINTENANCE IMPORTANT • The cooler is supplied with Honeycomb Cooling Media. • The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits.
CLEANING & MAINTENANCE DRAINING AND CLEANING THE WATER TANK • • • • • Turn the power “off” and disconnect the air cooler from the power supply. Move the unit to a location where it can be drained. Remove the cap from the water drain plug and allow the tank to empty (see parts description on page 7). After you have drained the water tank, please connect the water drain plug to its original position. Now refill the water tank up to Max level, wait for 5 min. and then drain the entire water once again.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is on. Power is not on. Turn the unit ON by pressing buttons on the control panel. Pump is not turned ON. On Control Panel, Turn COOL FUNCTION to “ON”. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calcium deposits on blower. Contact service center. When the Cooler is new.
TECHNICAL SPECIFICATIONS MODEL NO. Voltage Frequency Wattage Water Tank Capacity Cooling Media Product Dimension Net Weight CL48PM 230V 50Hz 130 Watts 40 Litre Honeycomb 600 (L) x 490 (W) x 830 (H) 13.
: © 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.