NOTHERM T8611G Owner's manual

T8611G CHRONOTHERM
®
DELUXE ZONING HEAT PUMP THERMOSTAT
3 69-1414—2
Fig. 4. Typical wiring diagram for T8611G on TotalZone® Control Panel.
Fig. 5. Correct wiring technique.
Mounting Thermostat
1. Engage tabs at the top of the thermostat and wall-
plate. See Fig. 6. Be sure to align subbase pins to
avoid damage to the thermostat.
2. Press lower edge of case to close and latch.
NOTE: To remove the thermostat from the wall, first pull
out at the bottom of the thermostat; remove top
last.
Fig. 6. Mounting thermostat on wallplate.
NORMALLY, WIRE E ON THERMOSTAT TO W1/E ON PANEL;
ALTERNATIVELY, INSTALL JUMPER FROM E TO Y ON
THERMOSTAT AND OMIT WIRE TO W1/E ON PANEL.
CONNECT O/B JUMPER ON TZ-4 PANEL WHEN O/B TERMINAL ON
THERMOSTAT IS CONFIGURED AS O.
CONNECT THE OC TERMINALS ONLY IF THE ZONE-A-LONE UNOCCUPIED
FEATURE IS DESIRED. SEE TZ-4 INSTALLER INSTRUCTIONS FOR EXPLANATION.
TZ-4
THERMOSTAT
CONNECTORS
1
2
3
2
C OC OC
E Y G O/BR W2 L OT OT
OC
OC
C7089B OUTDOOR
TEMPERATURE
SENSOR (OPTIONAL
)
M20932
1 3
M482
6
F
OR WRAPAROUND
I
NSERTION STRIP
7
/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
M1463
4
PRESS LOWER
EDGE OF CASE
TO LATCH.
ENGAGE TABS
AT TOP OF
THERMOSTAT
AND WALLPLATE.
A.
B
.