Owner's Manual

HON-62044:A • 08/31/2020Page 3 of 6
MECHANICAL AND ENVIRONMENTAL SPECIFICATIONS
Table 2 lists the mechanical and environmental specifications for each BDA model.
PSU (BDA-EPSU-300A-ASSY) Technical Specifications:
Table 3 lists the PSU Technical Specifications.
PSU Connections:
Table 4 lists the PSU Connections.
Batteries and Battery Enclosure
NEMA-4, UL Type-4 Listed Battery Enclosure
12V / 75Ah battery, minimum two are required for each BDA .
Donor Antennas
Installed on the Roof of the building.
Pointing to the public safety radio repeater site, line of sight not
required.
High gain, high directivity Yagi Antennas for various frequency
bands.
DAS Antennas
Installed in-building based on the design to achieve coverage.
Fiberglass and Low Profile antennas for various frequency bands.
Coaxial Cable
Plenum Rated, ½” diameter with low insertion loss.
Red cable color to differentiate for Public Safety BDA use.
Connectors and Lighting Arrestors
Various types of connectors, cable jumpers for ½” cable.
Coaxial surge protector, UL listed.
Cable jumper and Antenna Sensor / EOL termination for Donor
Antenna.
Power Dividers and Hybrid Couplers
2/3/4-way power dividers for various frequency bands.
Directional couplers for various dB and Frequency bands.
Services
Services for BDA iBwave System Design, Drawings, BOM.
Services for BDA Training
Specification
HON-BDA400-D5-1A HON-BDA400-D5-1B HON-BDA800-D5-1A HON-BDA800-D5-1B HON-BDA7800-D5-2A HON-BDA7800-D5-2B
Enclosure
Environmental
Rating
NEMA-4 (Type-4) NEMA-4 (Type-4) NEMA-4 (Type-4) NEMA-4 (Type-4) NEMA-4
(Type-4)
NEMA-4 (Type-4)
Dimensions
(WxDxH)
23.23”x8.32” x24”23.23”x8.32” x24”23.23”x8.32” x24”23.23”x8.32” x24”23.23”x8.32” x25.4” 23.23”x8.32” x25.4
Weight (With
Duplexers)
Typ. (lbs)
<59<59<59<59<59 <59
Enclosure Color Red (RAL3000) Red (RAL3000) Red (RAL3000) Red (RAL3000) Red (RAL3000) Red (RAL3000)
Operating
Temperature
°F (°C)
-22 to +140
(-30 to +60)
-22 to +140
(-30 to +60)
-22 to +140
(-30 to +60)
-22 to +140
(-30 to +60)
-22 to +140
(-30 to +60)
-22 to +140
(-30 to +60)
Recommended
Operating
Environment
Temperature
°F (°C)
-14 to +86
(-10 to +30)
-14 to +86
(-10 to +30)
-14 to +86
(-10 to +30)
-14 to +86
(-10 to +30)
-14 to +86
(-10 to +30)
-14 to +86
(-10 to +30)
Table 2 Mechanical and Environmental Specifications
Specifications Settings
AC In 100 – 250V / 50-60Hz / 3A @ 120V
DC Out 28.5V / 7A Continuous Duty
Charging Current 5.5A
Supervisory Functions AC, Battery Capacity, Battery V,
Charging Current, Load Presence,
Temp, MCU PSU Diagnostic, V out,
I out
Protection DC Out and Charger Electronic
Current Limiting + ATC Mini Fuse.
AC Input Fuse
Operating Temperature -22 to +140 °F (-30 to +60 °C)
Enclosure Environmental
Rating
NEMA-4 (Type-4, Waterproof
UL Listed)
Enclosure Dimensions 24”W x 10”D x 24”H
Weight with PSU,
without batteries
51 lbs.
Table 3 PSU Technical Specifications
Component Connections
Enclosure Connections Requires NEMA-4 Waterproof Conduit
AC Power Connection Built-In Duplex Power Outlet Included
DC Connection Wire Terminal Included
(10-14AWG Wire)
Battery Connection Fuse and Wire Harness Included
Supervisory CAT-5 Jumper to BDA
Table 4 PSU Connections