User's Guide
Table Of Contents
- Voyager™ 1200g/1202g/1202g-BF User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- USB Serial Commands
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan© Bioptic Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- Wincor Nixdorf RS232 Mode A
- Keyboard Country Layout
- Keyboard Wedge Modifiers
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Cordless System Operation (Voyager 1202g)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- Page Button
- About the Battery
- Voyager 1202g Battery Removal
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Base Charging Modes
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Scanner Power Time-Out Timer
- RangeGate
- Batch Mode
- Scanner Name
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Cordless System Operation (Voyager 1202g-BF)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- About the Instant Charge Pack
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- Postal Codes
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance and Troubleshooting
- Reference Charts
5 - 17
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit
the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform
to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is.
When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data
Window (see page 9-2), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear.
Default = Off.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data
Formatting beginning on page 7-1). The hex code for the No Read symbol is 9C.
* Discard Partial Sequence
Required
On/Not Required
*Off
On
* Off