User's Guide
Table Of Contents
- Voyager™ 1200g/1202g/1202g-BF User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- USB Serial Commands
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan© Bioptic Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- Wincor Nixdorf RS232 Mode A
- Keyboard Country Layout
- Keyboard Wedge Modifiers
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Cordless System Operation (Voyager 1202g)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- Page Button
- About the Battery
- Voyager 1202g Battery Removal
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Base Charging Modes
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Scanner Power Time-Out Timer
- RangeGate
- Batch Mode
- Scanner Name
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Cordless System Operation (Voyager 1202g-BF)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- About the Instant Charge Pack
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- Postal Codes
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance and Troubleshooting
- Reference Charts
1 - 6
Reading Techniques
The scanner has a view finder that projects a bright red aiming beam that corresponds to the scanner’s horizontal field of view.
The aiming beam should be centered horizontally over the bar code and must highlight all the vertical bars of the bar code. It
will not read if the aiming beam is in any other direction.
The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Symbologies
with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size)
should be read farther from the unit. To read single or multiple symbols (on a page or on an object), hold the scanner at an
appropriate distance from the target, press the button, and center the aiming beam on the symbol. If the code being scanned is
highly reflective (e.g., laminated), it may be necessary to tilt the code up 15° to 18° to prevent unwanted reflection.
Menu Bar Code Security Settings
Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want
to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the nearest techni-
cal support office (see Customer Support on page -iii) for further information.
Setting Custom Defaults
You have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults
bar code below before each menu command or sequence you want saved. If your command requires scanning numeric codes
from the back cover, then a Save code, that entire sequence will be saved to your custom defaults. Scan the Set Custom
Defaults code again before the next command you want saved to your custom defaults.
Note: If using a cordless system, scanning the Save Defaults bar code also causes both the scanner and the base to perform
a reset and become unlinked. The scanner must be placed in its base to re-establish the link before any setup codes are
entered. See Cordless System Operation (Voyager 1202g) beginning on page 3-1 or Cordless System Operation
(Voyager 1202g-BF) beginning on page 4-1 for additional information.
You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite
the old one. For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide
you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High
menu code The rest of the custom defaults will remain, but the beeper volume setting will be updated.
Good Read Bad Read
Set Custom Defaults