Datasheet

6
sensing.honeywell.com
E6/V6 Series
Table 3. Electrical Ratings
Rating Code UL, CSA Rating CE Rating
A
15 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
B
10 A @ 125 Vac, 250 Vac
0.3 A @ 125 Vdc, 0.15 A @ 250 Vdc
C
15 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
D
8 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
E
10 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
F
15 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
1.0 A @ 125 Vdc, 0.5 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
G
22 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
H 1A @ 125 Vac (Gold-plated contacts)
IEC 61058-1
1A, 250 Vac
Table 4. CE Electrical Rating, EN60947-5-1, IEC 60947-5-1
Designation &
Category
Vac Amps Make Amps Break
Continuous
Current (A)
VA Rating Make VA Rating Break
AC15, B300 120 30 3.0 5 3600 360
AC15, B300 240 15 1.5 5 3600 360
Table 5. Switching
SPDT DPDT SPDT-DB
C
NC
NO
C
NC
NO
C
NC
NO
NC
NC
NO
NO