Product Manual
Table Of Contents
- 1. Standard Contents
- 2. General Information
- 3. User Interface & Display Overview
- 4. BLE (Bluetooth Low Energy) Operation
- 5. Battery
- 6. Turning The Honeywell BW Solo On & Off
- 7. Navigation
- 8. Navigation: Information Menu
- 9. Navigation: Settings
- 10. Zeroing
- 11. Bump Testing
- 12. Calibrating
- 13. Replacing The Filter & Sensor
- 14. Maintenance
- 15. Firmware Update
- 16. Year Of Manufacture
- 17. Sensors & Settings
- 18. Troubleshooting
- 19. Honeywell BW Solo Specifications
- 20. Limited Warranty and Limitation of Liability
Honeywell BW Solo User Manual
43
The following are available sensors for the Solo Lite (not available in North America):
Gas
Type
Range
Resolution
Temperature
Low
Setpoint
High
Setpoint
H
2
S
0-100 ppm
0.1
-20 to +50° C/-4 to 122°F
10 ppm
15 ppm
CO
0-1000 ppm
1 ppm
-20 to +50° C/-4 to 140°F
35 ppm
200 ppm
O
2
0-30% v/v
0.1 %v/v
-20 to +50° C/-4 to 140°F
19.5 %v/v
23.5 %v/v
H
2
S
(extended
range)
0-500 ppm
0.1*
-40 to +50° C/-40 to 122°F
10 ppm
15 ppm
CO-H
0-2000 ppm
0.5 ppm
-30 to +50° C/-22 to 122°F
35 ppm
200 ppm
NH
3
0-100
1 ppm
-20 to +40° C/-4 to 104°F
25 ppm
50 ppm
NH
3
(extended
range)
0-1000
1 ppm
-20 to +40° C/-4 to 104°F
25 ppm
50 ppm
SO
2
0-100 ppm
0.1 ppm
-30 to +50° C/-22 to 122°F
2 ppm
5 ppm
HCN
0-100 ppm
0.1 ppm
-20 to +50° C/-4 to 122°F
4.7 ppm
10 ppm
Cl
2
0-50 ppm
0.1 ppm
-20 to +40° C/-4 to 104°F
0.5 ppm
1.0 ppm
NO
0-250 ppm
0.2 ppm
-30 to +50° C/-22 to 122°F
25 ppm
25 ppm
NO
2
0-100 ppm
0.1 ppm
-20 to +50° C/-4 to 122°F
2 ppm
5 ppm
PH
3
0-5 ppm
0.1 ppm
-20 to +50° C/-4 to 122°F
0.300 ppm
1.00 ppm
ETO
0-100 ppm
0.1 ppm
-30 to +50° C/-22 to 122°F
1 ppm
5 ppm
ClO
2
0-1 ppm
0.01 ppm
-20 to +40° C/-4 to 104°F
0.10 ppm
0.30 ppm
O
3
0-1 ppm
0.01 ppm
-30 to +50° C/-22 to 122°F
0.10 ppm
0.20 ppm
H
2
0-1000 ppm
2 ppm
-20 to +50° C/-4 to 122°F
100 ppm
500 ppm
* 1-Series sensor