Datasheet
4 www.honeywell.com/sensing
Contains advanced microstructure technology to provide a sensitive and fast response
to flow, amount/direction of air or other gases. Potential applications include HVAC, gas
metering, chromatography, vent hoods, and medical equipment.
Airow Sensors
Series AWM5000 AWM700
Signal conditioning
amplified amplified
Technology
silicon die silicon die
Flow/pressure range
0 SLPM to 5.0 SLPM; 0 SLPM to 10.0 SLPM;
0 SLPM to 15.0 SLPM; 0 SLPM to 20.0 SLPM
200 SLPM
Output
analog analog
Power consumption
100 mW max. 60 mW max.
Port style
1/4 in-18 NPT 22 mm tapered
Media compatibility
dry gas only dry gas only
Operating
temperature range
-20 °C to 70 °C [-4 °F to 158 °F] -25 °C to 85 °C [-13 °F to 185 °F]
Measurements
(H x W x D)
35,6 mm x 162,8 mm x 32,3 mm
[1.40 in x 6.41 in x 1.27 in]
33,8 mm x 22,9 x 37,0 mm
[1.33 in x 0.90 in 1.40 in]
Features
sensitivity to low flows; enhanced response
time; low power consumption; analog output;
laser trimmed
sensitivity to low flows; enhanced response
time; low power consumption; analog output;
highly stable
Series AWM40000 AWM90000
Signal conditioning
unamplified or amplified unamplified
Technology
silicon die silicon die
Flow/pressure range
±25.0 SCCM; 1.0 SLPM; 6.0 SLPM
±200 SCCM;
±5.0 mbar [2.0 in H
2
0]
Output
analog analog
Power consumption
60 mW max. or 75 mW max. 50 mW typ.
Port style
manifold parallel
Media compatibility
dry gas only dry gas only
Operating
temperature range
-40 °C to 125 °C [-40 °F to 251 °F] (inclusive) -25 °C to 85 °C [-13 °F to 185 °F]
Measurements
(H x W x D)
12,7 mm x 30,5 mm x 30,2 mm
[0.50 in x 1.2 in x 1.19 in]
13,08 mm x 30,48 mm x 27,94 mm
[0.52 in x 1.2 in x 1.1 in]
Features
sensitivity to low flows; enhanced response
time; low power consumption, analog output;
laser trimmed
sensitivity to low flows; fast response time; low
power consumption; analog output; bidirectional
sensing capability