Datasheet

Airflow Sensors AWM3000 Series
Microbridge Mass Airflow/Amplified
74
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
AWM3000 SERIES ORDER GUIDE (Performance Characteristics @ 10.01 ±0.01 VDC, 25°C)
Catalog Listings AWM3200CR* AWM3201CR* AWM3303V
Flow Range (Full Scale) ±1000 sccm (1 SLPM)
Differential Pressure Range 0 - 2N H
2
O (5 mBar) 0 - 0.5N H
2
O (1.25 mBar)
Output Type 4 - 20 mA DC (linear) 4 - 20 mA DC (linear) 1 - 5 VDC (Note 2)
Output @ Trim Point 20.0 ±1 mA DC @ 2N H
2
O 20.0 ±1 mA DC @ .05N H
2
O 5.00 ±0.150 VDC
Null Output 4.00 ±0.3 mA DC 4.00 ±0.4 mA DC 3.00 ±0.050 VDC
Null Shift
+25° to 25°C, +25° to +85°C ±2 mA DC (max.) ±2 mA DC (max.) ±.050 VDC (max.)
Output Shift
+25° to 25°C +24% Reading +32% Reading 5% Reading
+25° to +85°C 31% Reading (Note 3) 32% Reading (Note 3) +5% Reading
Linearity Error ±5% Reading ±5% Reading N/A
External Output Load 100 - 300 (Note 4) 100 - 300 (Note 4) N/A
Response Time (Note 1) 60 msec (max.) 60 msec (max.) 3 msec (max.)
Repeatability & Hysteresis, Max. ±0.50% Reading ±0.50% Reading ±1% Reading
Excitation VDC 10 ±0.01 10±0.01 8-15
Power Consumption (mW) 50 100
Common Mode Pressure (psi) 25
Calibration Gas Nitrogen
Temperature Range Operating: 25° to +85°C (13° to +185°F); Storage: 40° to +90°C (40° to +194°F)
Termination 2,54 mm (.100N) centers, 0,635 mm (0.025N) square
Weight (grams) 10.8
Shock Rating 100 g peak (5 drops, 6 axes)
Notes:
1. Initial warm-up time for signal conditioned circuitry is 1 minute max.
2. Output Voltage is ratiometric to supply voltage.
3. Temperature shifts when sensing differential pressure correlates to the density change of the gas over temperature.
4. Output load connected from V
OUT
to GND (current sinking).
5. Maximum allowable rate of flow change to prevent damage: 5.0 SLPM/1.0 sec.
* A 5 micron filter must be used on differential pressure sensors.
MOUNTING DIMENSIONS (for reference only)
Note: Positive flow direction is defined as proceeding from
Port 1 (P1) to Port 2 (P2) and results in positive output. Do not
exert a force greater than 4.54kg (10 lbs.) in any direction.