Datasheet

Airflow Sensors AWM3000 Series
Microbridge Mass Airflow/Amplified
72
Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
AWM3000 SERIES ORDER GUIDE (Performance Characteristics @ 10.01 ±0.01 VDC, 25°C)
Catalog Listings AWM3100V AWM3150V AWM3200V AWM3300V
Flow Range (Full Scale) +200 sccm +30 sccm +1000 sccm
Pressure Range
(See Application Note 1) +2.0N H
2
O (5 mBar)
Output Voltage @ Trim Point 5 VDC @ 200 sccm 3.4 VDC @ 25 sccm 5 VDC @ 2N H
2
O 5 VDC @ 1000 sccm
Null Voltage 1.00 ±0.05 VDC 1.00 ±0.10 VDC 1.00 ±0.08 VDC 1.00 ±0.10 VDC
Null Voltage Shift, Typ.
+25° to 25°C, 25° to +85°C ±25 mV ±100 mV ±25 mV ±25 mV
Output Voltage Shift, Max.
+25° to 25°C 4% Reading ±5% Reading +24% Reading (Note 3) 5% Reading
+25° to +85°C +4% Reading ±5% Reading 24% Reading +5% Reading
Repeatability & Hysteresis, Max. ±0.50% Reading ±1% Reading ±0.50% Reading ±1% Reading
Min. Typ. Max.
Excitation VDC (Note 2) 8.0 10±0.01 15
Power Consumption (mW) 50 60
Response Time (msec) (Note 1) 1.0 3.0
Common Mode Pressure (psi) 25
Temperature Range Operating: 25° to +85°C (13° to +185°F); Storage: 40° to +90°C (40° to +194°F)
Termination 2,54 mm (.100N) centers, 0,635 mm (0.025N) square
Weight (grams) 10.8
Shock Rating 100 g peak (5 drops, 6 axes)
Notes:
1. Initial warm-up time for signal conditioned circuitry is 1 minute max.
2. Output Voltage is ratiometric to supply voltage.
3. Temperature shifts when sensing differential pressure correlates to the density change of the gas over temperature. (See Application Note 1.)
4. Maximum allowable rate of flow change to prevent damage: 5 SLPM/1 sec.
MOUNTING DIMENSIONS (for reference only)
Note: Positive flow direction is defined as proceeding from
Port 1 (P1) to Port 2 (P2) and results in positive output. Do not
exert a force greater than 4.54kg (10 lbs.) in any direction.