Users Manual

ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 6-2
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
(b) Supports a minimum of 5000 Historical Security Records;
(c) Stores the most recent Historical Security Records should the capacity be
exceeded.
NOTE: When the Historical Security Log is full it is acceptable to "age out" a
significant block of the oldest records (e.g. 500), rather than doing this
one record at a time, if this provides a substantial overall saving in
CPU processing time.
(2) For each security log Fault and Event that has occurred in the current flight leg, the ACD
maintains an occurrence count and record its value in any stored records.
(3) The ACD limits the maximum number of Security Log Fault and Events records of a
specific type entered per hour to 3, with additional occurrences in the hour only counted,
and all counts cleared with new flight leg.
NOTE: for intermittent faults 3 Set records and 3 clear records are expected.
(4) When the Syslog ORT option is enabled;
(a) The ACD streams 'INFO' and 'WARNING' level security records via the Syslog
protocol over the Ethernet 3 interface to the ORT configured destination IP
address.
NOTE: The INFO and WARNING levels refer to Syslog RFC3164 definitions
and not historical logging levels
(5) When the Syslog ORT option is enabled;
(a) The ACD formats Syslog messages as follows:
1 [<service>‘-‘<group>‘]:‘<sp><message-text>
2 Where the values of <service> are shown in Table 6-1 below.
Table 6-1. Service Descriptions of Syslog Messages Formatted by ACD
Service Service Description
DATALOAD
Data load service
FTST FTS
Translation Function
EMU Engine Management Unit
DFDAU Digital Flight Data Acquisition Unit
CSS Cabin Services System
3 The values for <group> are shown in Table 6-2 below.
NOTE: Please note the associated PRI section with each message
group.
DRAFT
3rd rvw Draft as of:
29 January, 2020