Users Manual

ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 5-46
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
Table 5-10. Label 377 Subsystem Identifier (Continued)
Bit Range Field Name (Discrete Format) Valid Values/Ranges
10b SDU 2
11-14
Equipment ID Code (LSD)
0000b = 0x1
15-18
Equipment ID Code
0100b = 0x4
19-22 Equipment ID Code (MSD) 0000b = 0x0
23-29
Spare
0
30-31 SSM (Notes bits 30-31) 00 Normal Operation
10 Functional Test
32 Parity
Odd
(3) The ACD transmits the following Label 172o Subsystem Identifier Word on the "Data to
MCDU 1,2,3" interface, with a period of 1 s +/- 500 ms:
Table 5-11. Subsystem Identifier Word
Bit Range Field Name (Discrete Format) Valid Values/Ranges
1-8 Label
172 (octal)
9-16
Subsystem SAL 307 = SDU 1
173 = SDU 2
17
Master/Slave Dual SATCOM 1 = Master or Standalone
0 = Slave
18-29 18-29 0
30-31
SSM (Note bits 30-31) 00 Normal Operation
10 Functional Test
32 Parity
Odd
NOTE: this label encodes the SDU SAL although it is not required by the WSCI
Protocol its presence is specifically permitted for possible use.
(4) The ACD permits Label 172o on any of the ORT activated A429 MCDU receive
interfaces. No action is taken on the content of this label. This label may or may not be
present on all A429 receive interfaces.
F. MCDU ARINC 739 Variant
(1) If ORT indicates ARINC 739 MCDU, the ACD enables and setS the speed of the "Data to
MCDU 1,2,3" interface based on the ORT.
G. SDU to MCDU - ARINC 739 Transmit Labels
(1) If ORT configured for the following:
(a) Aircraft Directed Dual Safety SATCOM
DRAFT
3rd rvw Draft as of:
29 January, 2020