Users Manual

ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page A-10
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
Table A-2. TCCA CAN-TSOs for the Aspire 400 (Continued)
CAN-TSO-
C159d [RD8]
Next Generation Satellite Systems (NGSS)
Equipment
DO-262D [RD12]
(1)
SATVOICE & SAT
DATA
(3) The planned CAN-TSO submittals are itemized inTable A-3 below.
Table A-3. Planned CAN-TSO submittals
Planned CAN-TSO Submittals Class or Subclass
Applicable Aspire 400 LRUs
Initial Major
AES6F SDU, SCM, HPA
Follow-on Major (after AES6F
approved)
AES7F subclass SDU, SCM, HPA
B. Deviations for Aspire 400
(1) Deviations from the RTCA/DO-262 [RD12] for Aspire 400 are as follows:
(a) DO-262 Rev D [RD15] will be followed instead of Rev C indicated in CAN-TSO-
C159d [RD9].
(b) For the SDU, SCM and HPA, the Class, and Subclass information will be
included in the System Description Installation Manual (SDIM). The physical
CAN-TSO nameplate/marking on the exterior of the SDU, SCM and HPA LRU’s
will have the statement “(Class/Subclass: See IM)” to point to the location of this
information.
(c) The AES (Aeronautical Earth Station) allocation of a voice delay may not be met
based on analysis. A deviation request will only be made if necessary.
C. CAN-TSO Functions
(1) All functions are CAN-TSO Functions. MOPS identified test data is not provided for the
following Aspire 400 functions summarized below, which are deactivated via interlocks in
the initial CAN-TSO submittal:
(a) ATN Test Feature
1 Requirements and software are present to permit testing of ATN data.
Multiple interlocks are provided to prevent this function from being
activated in error. These include:
a ORT parameter that cannot be selected with ORTschemas
delivered to customers.
b Software confirmation that if ORT parameter is selected, that a
hardware discrete not wired in standard plan wiring is asserted.
2 Support for Classes not in current CAN-TSO submittal (example AES7F
at time of AES6F submittal)
a SDU behavior alignment to configured class in the Secure ORT
file (parameter data items) is fully tested as described above.
DRAFT
3rd rvw Draft as of:
29 January, 2020