Users Manual
ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 3-4
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
a Location ID
b Description.
H. Safety Voice
(1) The ACD ensures the ORT contains the following parameters for SBB Safety Voice
configuration:
(a) APN
(b) SIP Domain name.
(2) 4-wire Noise insertion (A781 Ref D6) applied to Classic voice, AMBE +2 codec provides
its own specified noise insertion.
I. ACD Voice Configuration
(1) The ACD ensures the ORT contains the following cockpit voice parameters:
(a) G2A Public calls permission
(b) Caller ID:
1 Enable
2 Disable.
(c) 4-wire:
1 Connectivity
2 Preferred routing for Ground-to-Air Calls.
(d) Cockpit headset parameters:
1 Audio level
2 Mic level
3 Side tone level.
(e) Hook switch operation:
1 Latched
2 PTT.
(f) Call Pre-Select.
(g) Call Discretes.
1 Alternate behavior
2 Standard behavior.
(2) There is no requirement to support the following as an ORT configurable item:
(a) Phone number preset (A781 Ref D8) "MAKE CALL" activation by an MCDU to
initiate dialing of a number.
(b) Placement of Calls using Place / End Call Discretes (A781 Ref D11) is only
necessary if A781 Ref D8 is enabled.
(3) The following ORT parameters are not supported:
(a) Cockpit Air-Ground Call Camp On Timer (A781 Ref D5) has the capability of pre-
empting on-going call attendant call at any time, it is not based on a timer.
DRAFT
3rd rvw Draft as of:
29 January, 2020