Users Manual
ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 3-3
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
(g) Minimum initial EIRP for Switft64 (A781 Ref E8):
1 Not applicable to SBB.
(6) The ACD ensures that all ACD ORT parameters are assigned to the Secure ORT except
for the following User ORT parameters:
(a) SBB Service Provider APN
(b) Cockpit Telephone Directory
(c) Login Policy
(d) Manual Dial Mode.
(7) The AISD ensures that all AISD ORT parameters are assigned to the Secure ORT.
(8) The PIESD ensures that all PIESD ORT parameters are assigned to the Secure ORT.
F. Satellite Table
(1) The ACD ensures the ORT contains the following information for up to 16 satellites:
(a) Satellite identity
(b) Name
(c) Position
(d) Priority
(e) SBB global beam frequencies.
G. SBB Safety Data
(1) The ACD ensures the ORT contains the following parameters for SBB Safety Data
configuration:
(a) AAP Position Reporting
(b) APN for the SBB Gateway
(c) DNS Lockup name for the SBB Gateway.
(d) Supported Safety Services for ACARS (CMU using Williamsburg V1 protocol).
(e) SBB Type Approval Code
(f) Aircraft Type.
(g) Location ID
(h) SATCOM 1
1 Not Applicable
2 Applicable.
a Location ID
b Description.
(i) SATCOM 2.
1 Not Applicable
2 Applicable.
DRAFT
3rd rvw Draft as of:
29 January, 2020