Programming Manual
TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control):
A. POWER UP, then press [
✱
] and [#] at the same time, within 50 seconds of powering up (this method must be used if
✱
98
was used to exit program mode). OR
B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
PROGRAMMING MODE COMMANDS
Task Command/Explanation
Go to a Data Field
Press [∗
∗∗
∗] + [Field Number], followed by the required entry.
Entering Data
When the desired field number appears, simply make the required entry. When the last entry
for a field is entered, the keypad beeps three times and automatically displays the next data
field in sequence. If the number of digits that you need to enter in a data field is less than the
maximum digits available (for example, the phone number fields *41, *42), enter the desired
data, then press [∗ ] to end the entry. The next data field number is displayed.
Review a Data Field Press [#] + [Field Number].
Data will be displayed for that field number. No changes will be accepted in this mode.
Deleting an Entry
Press [∗
∗∗
∗] + [Field Number] + [∗
∗∗
∗]. (Applies only to fields ∗40 thru *46, *94, and pager fields)
Initialize Download ID
Press ∗
∗∗
∗96. Initializes download ID and subscriber account number.
Reset Factory Defaults
Press ∗
∗∗
∗97. Sets all data fields to original factory default values.
Zone Programming
Press ∗
∗∗
∗56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800
RF transmitters.
Function Key Programming
Press ∗
∗∗
∗57. Unlabeled keypad keys (known as ABCD keys) for special functions
Zone Programming
(Expert Mode)
Press ∗
∗∗
∗58. Same options as *56 mode, but with fewer prompts. Intended for those familiar
with this type of programming, otherwise *56 mode is recommended.
Output Device Mapping
Press ∗
∗∗
∗79. Assign module addresses and map individual relays/powerline carrier devices
Output Programming
Press ∗
∗∗
∗80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers
Zone List Programming
Press ∗
∗∗
∗81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.
Alpha Programming
Press ∗
∗∗
∗82. Zone alpha descriptors
Exit Program Mode with
installer code lockout
Press ∗
∗∗
∗98. Exits programming mode and
prevents
re-entry by: Installer Code + 8 + 0 + 0.
To reenter programming mode, the system must be powered down, then powered up. Then
use method A above. See field *88 for other *98 Program mode lockout options.
Exit Program Mode
Press ∗
∗∗
∗99. Exits programming mode and
allows
re-entry by: Installer Code + 8 + 0 + 0 or
method A above.
SPECIAL MESSAGES
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds.
This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this
delay by pressing [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after
you correct the programming.
TABLE OF DEVICE ADDRESSES
This Device Uses Address Reports as †† Enabled By…
RF Receiver 00 100 *56 zone programming: input device type entry
AUI 1 01 101 Automatic if AUI enable field *189 enabled for AUI 1
AUI 2 02 102 Automatic if AUI enable field *189 enabled for AUI 2
Long Range Radio 03 103 automatic if output to long range radio field *29 enabled
4286 Voice Module 04 104 automatic if phone module access code field *28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 zones 33 - 40
module 5 zones 41 - 48
07
08
09**
10**
11**
107
108
109
110
111
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
12
13
14**
15**
112
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module 28 n/a automatic
** These module addresses apply to VISTA-20P only.
†† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
– 2 –