Generator Placement
18 Installation Guidelines for 60 Hz Air-Cooled Generators
Fascia Installation (If Applicable)
Locate the four threaded black rubber bumpers
supplied with the loose parts. (See Parts Shipped
Loose.)
See Figure 4-3. Remove the bumpers from the
bag and screw them into threaded holes located
inside the end pieces of the fascia (two each)
opposite one another (A).
Figure 4-3. Fascia Installation
Snap one of the end pieces into one of the front/
rear pieces of fascia. Repeat this action with the
other two remaining pieces of fascia (B).
NOTE: Do not assemble all four pieces together at this
point.
Place both assemblies at the base of the generator
and fit the rubber mounts into the lifting holes in the
generator base (C).
Once aligned, snap together the two remaining
connection points.
000614
B
A
C