Unpacking and Inspection
8 Installation Guidelines for 60 Hz Air-Cooled Generators
6. See Figure 2-3. Remove bolts and pallet brackets
(A). Exercise caution when removing the
generator. Do not drag unit off pallet. Doing so will
damage the base. The generator must be lifted
from the wooden pallet to remove.
NOTE: Bolts and pallet brackets are provided only for
shipping purposes and can be discarded after removal.
Figure 2-3. Generator on Pallet
7. See Figure 2-4. Two locks (A) secure the lid; one
on each side. Press down on the lid above the side
lock, and unlock the latch to properly open the lid.
8. Repeat for the other side. The lid may appear stuck
if pressure is not applied from the top.
NOTE: Always verify side locks are unlocked before
attempting to lift the lid.
9. Remove front access panel by lifting it straight up
and out once the lid is open.
NOTE: See Figure 2-4.
Always lift the front access panel
straight up before pulling away from enclosure (B and C).
Do not pull the panel away from the enclosure before lifting
up (D).
Figure 2-4. Side Lock Location and Front Panel Removal