The table below shows the results of the Auto Reconnect On and Off settings:
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner
tries to form a connection with a base or an Access Point. During the connection
setup process, the scanner transmits in order to search for and connect to a base
or an Access Point. In order to prevent continuous transmissions that could inter-
fere with other users of the ISM band, the number of attempts to connect is limited
by this setting. After the maximum number of attempts is reached, the scanner will
not attempt to reconnect to a base or an Access Point. Pressing the trigger, scan-
ning an Access Point linking bar code, or placing the scanner in the cradle resets
the attempt count and the scanner will again try to link.
Event Auto Reconnect On Auto Reconnect Off
Scanner out of range Relink occurs automatically. If
maximum number of link attempts
is unsuccessful, then the scanner
must be relinked by either pulling
the trigger, placing the scanner in
the base, or scanning the Access
Point linking bar code. (See
Maximum Link Attempts on page
77.)
The scanner is relinked by
pulling the trigger, or scanning
the Access Point linking bar
code.
Base or Access point reset
(firmware upgrade or power
cycle)
Scanner behaves as if out of range. No attempt to relink made
while base or Access Point is
powered off. Trigger must be
pulled to initiate relinking.
Scanner power down due to
Power Time-Out Timer
setting
Trigger must be pulled, Access Point linking bar code must be
scanned, or the scanner must be placed in the base unit to relink.
(Note: scanner relinks on power up, but powers on due to one of the
above actions.)
Scanner reset due to
firmware upgrade
Relink occurs automatically.
Scanner reset due to battery
or charge pack change
Relink occurs automatically.
Scanner placed in different
base unit
Relink to new base occurs automatically.