User Manual
254 Xenon XP User Guide
Good Read Delay *No Delay DLYGRD0 88
Short Delay (500 ms) DLYGRD500 88
Medium Delay (1000 ms) DLYGRD1000 88
Long Delay (1500 ms) DLYGRD1500 88
User-Specified Good Read Delay Range 0 - 30,000 ms DLYGRD##### 88
Trigger Modes *Manual Trigger - Normal PAPHHF 89
Manual Trigger - Enhanced PAPHHS 89
Trigger Toggle
*Trigger Toggle Off TRGTGM0 89
Trigger Toggle - Image Capture TRGTGM1 89
Trigger Toggle Off - Centering TRGTGM3 89
Trigger Number
2 Quick Triggers TRGTPC2 90
3 Quick Triggers TRGTPC3 90
4 Quick Triggers TRGTPC4 90
Trigger Timing
Trigger Timing (Range 50 - 2000)
*400
TRGTTI#### 90
Trigger Toggle Timeout
Trigger Toggle Timeout (Range 0 -
65) *5
TRGTGT## 90
Serial Trigger Mode Read Time-Out
(0 - 300,000 ms) *30,000
TRGSTO#### 91
Presentation Mode Presentation Mode PAPTPR 91
Triggered Presentation Mode Ambient Light Only PDCLED0 92
*Ambient and Scanner Light PDCLED1 92
Presentation LED Behavior After
Decode
*LEDs On TRGPCK1 92
LEDs Off TRGPCK0 92
Presentation Centering Window Presentation Centering On PDCWIN1 93
*Presentation Centering Off PDCWIN0 93
Left of Presentation Centering
Window (*40%)
PDCLFT### 94
Right of Presentation Centering
Window (*60%)
PDCRGT### 94
Top of Presentation Centering
Window (*40%)
PDCTOP### 93
Bottom of Presentation Centering
Window (*60%)
PDCBOT### 93
In-Stand Sensor Mode Sensor On TRGSSW1 94
Sensor Off TRGSSW0 94
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page