User manual
4 - 15
Deactivation Character
This sets the character used to terminate scanning when using Character Deactivation Mode. On the ASCII Conversion
Chart (Code Page 1252), page A-3, find the hex value that represents the character you want to use to terminate scanning.
Scan the following bar code, then use the Programming Chart inside the back cover of this manual to read the alphanu-
meric combination that represents that ASCII character. Scan Save to finish. Default = 14 [DC4].
Illumination Lights
If you want the illumination lights on while reading a bar code, scan the Lights On bar code, below. However, if you want to turn
just the lights off, scan the Lights Off bar code. Default = Lights On.
Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (page 4-16).
Aimer Delay
The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the
time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but
the LEDs won’t turn on until the delay time is over. Default = Off.
On
Deactivation Character
* Lights On
Lights Off
200 milliseconds
400 milliseconds
* Off (no delay)