User's Guide

172 HH1800 User Guide
Selection
Setting
* Indicates default
Serial Command # Indicates a
numeric entry
Page
ACK/NAK On
232ACK1
22
Scanner-Bioptic Packet Mode
*Packet Mode Off
232PKT0
Packet Mode On
232PKT2
Scanner-Bioptic ACK/NAK Mode
*Bioptic ACK/NAK Off
232NAK0
Bioptic ACK/NAK On
232NAK1
Scanner-Bioptic ACK/NAK Timeout
ACK/NAK Timeout (1-30000 milliseconds)
*5100
232DLK#####
Input/Output Selections
Power Up Beeper
Power Up Beeper Off - Scanner
BEPPWR0
23
*Power Up Beeper On - Scanner
BEPPWR1
23
Beep on BEL Character
Beep on BEL On
BELBEP1
23
*Beep on BEL Off
BELBEP0
23
Trigger Click
On
BEPTRG1
24
*Off
BEPTRG0
24
Beeper - Good Read
Off
BEPBEP0
24
*On
BEPBEP1
24
Beeper Volume - Good Read
Off
BEPLVL0
24
Low
BEPLVL1
24
Medium
BEPLVL2
24
*High
BEPLVL3
24
Beeper Pitch - Good Read (Frequency)
Low (1600 Hz) (min 400 Hz)
BEPFQ11600
25
*Medium (2700 Hz)
BEPFQ12700
25
High (4200 Hz) (max 9000 Hz)
BEPFQ14200
25
Beeper Pitch - Error (Frequency)
*Razz (250 Hz) (min 200 Hz)
BEPFQ2800
25
Medium (3250 Hz)
BEPFQ23250
25
High (4200 Hz) (max 9000 Hz)
BEPFQ24200
25
Beeper Duration - Good Read
*Normal Beep
BEPBIP0
25
Short Beep
BEPBIP1
25
LED - Good Read
Off
BEPLED0
26
*On
BEPLED1
26
Number of Beeps - Good Read
(Range 1 - 9) *1
BEPRPT#
26
Number of Beeps - Error
(Range 1 - 9) *1
BEPERR#
26
Good Read Delay
*No Delay
DLYGRD0
27
Short Delay (500 ms)
DLYGRD500
27
Medium Delay (1000 ms)
DLYGRD1000
27
Long Delay (1500 ms)
DLYGRD1500
27
User-Specified Good Read Delay
Range 0 - 30,000 ms
DLYGRD#####
27
Trigger Modes
*Manual Trigger - Normal
PAPHHF
27
Manual Trigger - Enhanced
PAPHHS
27