User's Guide

Table Of Contents
7 - 5
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional
information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48.
Code 39 Append
This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to
the host computer. When the scanner encounters a Code 39 bar code with the append trigger character(s), it buffers Code
39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in the
order in which the bar codes were read (FIFO). Default = Off.
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as
PARAF.
Note: Trioptic Code (page 7-32) must be turned off while scanning Code 32 Pharmaceutical codes.
Validate, but Don’t Transmit
Validate and Transmit
Minimum Message Length
Maximum Message Length
On
* Off
On
* Off