User Manual
Table Of Contents
- Granit™ 1280i User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- RS232 Serial Port
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan® Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Input/Output Settings
- Power Save Mode
- Power Up Beeper
- Beep on BEL Character
- Good Read and Error Indicators
- Laser Aimer
- LED Indicators
- Out-Of-Stand Settings
- Reread Delay
- CodeGate®
- Character Activation Mode
- Character Deactivation Mode
- Centering
- Blinky Mode
- Laser Scan Angle
- Decode Security
- Continuous Scan Mode
- Output Sequence Overview
- No Read
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- Matrix 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- China Post (Hong Kong 2 of 5)
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
- Reference Charts
- Sample Symbols
- Programming Chart
6 - 20
ISBT 128 Predefined Concatenation Sequences On/Off
The following selections allow you to enable or require the Predefined ISBT 128 Concatenation Sequences.
If you scan Off, the predefined concatenation sequences are disabled.
If you scan the Allow Predefined Sequence code, then the scanner will output only the data combination specified in the
predefined concatenation sequence you selected.
If you scan the Require Predefined Sequence code, the data combination specified in the predefined concatenation
sequence you selected is required to transmit the data. No data is output unless the sequence is read.
Default = Off.
ISBT 128 User-Defined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to create a custom ISBT 128 Concatenation Sequence. Select the identifiers you want to
transmit in the 1st and 2nd positions, both left and right. Refer to the ISBT 128 Standard Technical Specification for the list
of data identifiers.
Use the ASCII Conversion Chart (Code Page 1252), page A-2, to find the characters needed for the identifier. Locate the
hex value for each character and scan that 2 digit/character value from the Programming Chart inside the back cover of this
manual.
Example: You want to create a concatenation sequence that has the Donation Identification Number (001) as the left iden-
tifier, and Product Code (003) as the right identifier.
The ISBT Index of Data Structures shows that for the Donation Identification Number, the first character is “=” and the sec-
ond character can be from A-N; P-Z; 1-9. For this example, use “G.” The Product Code first character is “=” and the second
character is “<.”
* Off
Allow Predefined Sequence
Require Predefined Sequence