User Manual
Table Of Contents
- Granit™ 1280i User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- RS232 Serial Port
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan® Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Input/Output Settings
- Power Save Mode
- Power Up Beeper
- Beep on BEL Character
- Good Read and Error Indicators
- Laser Aimer
- LED Indicators
- Out-Of-Stand Settings
- Reread Delay
- CodeGate®
- Character Activation Mode
- Character Deactivation Mode
- Centering
- Blinky Mode
- Laser Scan Angle
- Decode Security
- Continuous Scan Mode
- Output Sequence Overview
- No Read
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- Matrix 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- China Post (Hong Kong 2 of 5)
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
- Reference Charts
- Sample Symbols
- Programming Chart
8 - 14
Telepen Default All Telepen
Settings
TELDFT 6-24
*Off TELENA0 6-24
On TELENA1 6-24
Telepen Output *AIM Telepen Output TELOLD0 6-24
Original Telepen Output TELOLD1 6-24
Telepen Redundancy Redundancy TELVOT## 6-25
Telepen Message Length Minimum (1 - 80) *3 TELMIN## 6-25
Maximum (1 - 80) *80 TELMAX## 6-25
UPC-A Default All
UPC-A Settings
UPADFT 6-25
Off UPBENA0 6-25
*On UPBENA1 6-25
UPC-A Check Digit Off UPACKX0 6-26
*On UPACKX1 6-26
UPC-A Number System Off UPANSX0 6-26
*On UPANSX1 6-26
UPC-A Addenda *2 Digit Addenda Off UPAAD20 6-26
2 Digit Addenda On UPAAD21 6-26
*5 Digit Addenda Off UPAAD50 6-26
5 Digit Addenda On UPAAD51 6-26
UPC-A Addenda Required *Not Required UPAARQ0 6-27
Required UPAARQ1 6-27
UPC-A Addenda
Separator
Off UPAADS0 6-27
*On UPAADS1 6-27
Addenda Timeout Range (0 - 65535) *100 DLYADD##### 6-27
UPC-A Redundancy Redundancy UPAVOT## 6-27
UPC-A/EAN-13 with Extended
Coupon Code
*Off CPNENA0 6-28
Allow Concatenation CPNENA1 6-28
Require Concatenation CPNENA2 6-28
UPC-A/Code 128 Coupon Code
Output
* Multiple Code Output CPNSTY0 6-28
Single Code Output CPNSTY1 6-28
UPC-A Number System 4 Addenda
Required
* Don’t Require Coupon Code ARQSY40 6-29
Require Coupon Code ARQSY41 6-29
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric entry
Page