User Manual
Table Of Contents
- Granit™ 1280i User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- RS232 Serial Port
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan® Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Input/Output Settings
- Power Save Mode
- Power Up Beeper
- Beep on BEL Character
- Good Read and Error Indicators
- Laser Aimer
- LED Indicators
- Out-Of-Stand Settings
- Reread Delay
- CodeGate®
- Character Activation Mode
- Character Deactivation Mode
- Centering
- Blinky Mode
- Laser Scan Angle
- Decode Security
- Continuous Scan Mode
- Output Sequence Overview
- No Read
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- Matrix 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- China Post (Hong Kong 2 of 5)
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
- Reference Charts
- Sample Symbols
- Programming Chart
8 - 7
Aimer Delay 200 milliseconds SCNDLY200 3-7
400 milliseconds SCNDLY400 3-7
*Off (no delay) SCNDLY0 3-7
User-Specified Aimer Delay Range 0 - 4,000 ms SCNDLY#### 3-7
LED Indicators Red LED Off LEDFN10 3-8
Green LED Off LEDFN20 3-8
Red LED On with Good Scan LEDFN11 3-8
*Green LED On with Good Scan LEDFN21 3-8
*Red LED On with Laser LEDFN12 3-8
Green LED On with Laser LEDFN22 3-8
Red LED On when CodeGate
Disabled
LEDFN14 3-8
Green LED On when CodeGate
Disabled
LEDFN24 3-8
Red LED On with CTS LEDFN1128 3-8
Green LED On with CTS LEDFN2128 3-8
Good Read Delay *No Delay DLYGRD0 3-9
Short Delay (500 ms) DLYGRD500 3-9
Medium Delay (1000 ms) DLYGRD1000 3-9
Long Delay (1500 ms) DLYGRD1500 3-9
User-Specified Good Read Delay Range 0 - 30,000 ms DLYGRD##### 3-9
Out-of-Stand Settings Out-of-Stand Defaults AOSDFT 3-9
Presentation Mode Out-of-Stand PAPPM3 3-10
Manual Activation Mode Off Out-
of-Stand
AOSMEN0 3-10
*Manual Activation Mode On Out-
of-Stand
AOSMEN1 3-10
Do Not End Manual Activation
After Good Read Out-of-Stand
AOSMGD0 3-10
*End Manual Activation After Good
Read Out-of-Stand
AOSMGD1 3-10
Laser Timeout - Trigger Hold Out-
of-Stand
(Range 1 - 65525) *30,000 ms
AOSMPT##### 3-11
Laser Timeout - Trigger Release
Out-of-Stand
(Range 1 - 65525) *0 ms
AOSMRT##### 3-11
Reread Delay Short (500 ms) DLYRRD500 3-11
*Medium (750 ms) DLYRRD750 3-11
Long (1000 ms) DLYRRD1000 3-11
Extra Long (2000 ms) DLYRRD2000 3-11
User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD##### 3-11
CodeGate CodeGate Off Out-of-Stand AOSCGD0. 3-12
*CodeGate On Out-of-Stand AOSCGD1. 3-12
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric entry
Page