User manual
82 Voyager 1250g User Guide
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the current cursor
position. The format is aborted if the character is numeric.
ED Example: Only output the data if the bar code begins with a letter
If you want only data from bar codes that begin with a letter, you can use ED to
check for the letter.
Command string: EDF10D
ED is the “Check for a non-numeric character” command
F1 is the “Send all characters” command
0D is the hex value for a CR
If this bar code is read, the next data format, if there is one, will
be used on this data. If there is no other format, the format fails and the raw data is
output as 1234AB.
If this bar code is read: the data is output as:
AB1234
<CR>
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the
current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms
increments, up to 9999. This command can only be used with keyboard emulation.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as read,
including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created and
saved. The following settings can be applied to your data format:
• Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
Data Formatter Off