User manual

Voyager 1250g User Guide 15
Note: If you are having unexpected results with this programming code, scan the Activate
Defaults bar code on page 149 first, then scan the programming bar code above.
Gilbarco
®
Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Gilbarco termi-
nal. This bar code sets the baud rate to 2400 bps and the data format to 7 data bits,
even parity, 2 stop bits. It also adds a carriage return (CR) suffix and programs the
following prefixes for each symbology:
Note: If you are having unexpected results with this programming code, scan the Activate
Defaults bar code on page 149 first, then scan the programming bar code above.
Honeywell Bioptic Aux Port Configuration
Scan the following Plug and Play code to program the scanner for a Honeywell
bioptic scanner auxiliary port configuration. This bar code sets the baud rate to
38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character RTS/
CTS with timeout and 232 ACK/NAK are also enabled.
Note: If you are having unexpected results with this programming code, scan the Activate
Defaults bar code on page 149 first, then scan the programming bar code above.
Verifone Ruby Settings
Symbology Prefix
UPC-A A
UPC-E E0
EAN-8 FF
EAN-13 F
Gilbarco Settings
Honeywell Bioptic Settings