User manual
Voyager 1250g User Guide 139
When Check Character is set to Validate and Transmit, the scanner only reads
Plessey bar codes printed with a check character, and will transmit this character at
the end of the scanned data. Default = No Check Character.
Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
adjust the redundancy, scan the Plessey Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the Programming Chart on page 202.
Then scan the Save bar code. Default = 0.
Plessey Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 88) for additional information. Minimum and Maximum lengths
= 1-80. Minimum Default = 3, Maximum Default = 80.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Plessey Redundancy
Minimum Message Length
Maximum Message Length