User Guide
Table Of Contents
INSTALLATION INSTRUCTIONS
62-3113-01
AMX300 DirectConnect™
Mixing Valve Kits
Included in this box (see Fig. 1)
1. AMX300 thermostatic mixing valve (“A”)
2. Cold water tee (“B”)
3. Flexible metal connector (“C”)
4. Thermostrip (“D”)
5. AMX300 Mixing Valve Installation Instructions
(literature # 62-3112)
6. AMX300 Mixing Valve Kit Installation Instructions
(literature # 62-3113)
Fig. 1. Mixing valve kit contents.
Tools needed (not supplied)
1. Wrench
2. Pliers
Safety Definitions
These safety terms identify information you must read.
CAUTION
Indicates a hazardous situation which, if not
avoided, could cause bodily injury or property
damage.
WARNING
Indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
GETTING STARTED
CAUTION
For the homeowner's comfort, safety and
convenience, it is recommended this mixing valve
kit be installed and serviced by a plumbing
professional.
These instructions provide detailed instructions for
installation and maintenance of the mixing valve kit.
You must read these instructions carefully and
completely to ensure proper installation.
Safety Precautions
WARNING
Water inside the water heater is very hot and
presents a scalding hazard.
Water temperatures in excess of 125 ºF (52 ºC) can
cause severe burns. Explain this to homeowner and
emphasize the risks associated with adjusting the
mixing valve settings.
A
B
C
D
M29694A
Thermostrip
Accuracy expires
after MMMYYYY
11043
11244
11446
11647
11848
12049
12250
12451
12652
12853
13054
13255
13456
13657
13858
14060
ºF ºc