33-00135EFS_B.book Page 1 Wednesday, November 11, 2015 11:31 AM ERM5220R Equipment Remote Module WITH REDLINK™ WIRELESS TECHNOLOGY INSTALL GUIDE Table of Contents About the ERM5220R 2 Installation Checklist 3 Terminal Designations 4 Installation 6 Checkout 12 Troubleshooting 14 Specifications 16 5 Year Warranty 18 CAUTION Read these installation instructions completely and follow them carefully.
33-00135EFS_B.book Page 2 Wednesday, November 11, 2015 11:31 AM About the ERM5220R THERMOSTAT ERM WIRE CONDENSING UNIT ERM BOILER MCR35654 Fig. 1. • Wireless RedLink™ communication between condensing unit/ compressor or boiler and thermostat. • Eliminates the need to run additional wires to your equipment, for example, during a heat pump upgrade. • Suitable for outdoor use. • Temperature sensor terminals for outdoor temp sensors or indoor freeze protection. • LEDs for easy installation checkout.
3-00135EFS_B.book Page 3 Wednesday, November 11, 2015 11:31 AM Installation Checklist MATERIALS SUPPLIED: ERM5220R Equipment Remote Module WITH REDLINK™ WIRELESS TECHNOLOGY INSTALL GUIDE Table of Contents About the ERM5220R Installation Checklist Terminal Designations Installation 2 3 4 6 Checkout 12 Troubleshooting 14 Specifications 16 5 Year Warranty 18 CAUTION Read these installation instructions completely and follow them carefully.
S1 S1 L SECOND STAGE OF TWO STAGE COMPRESSOR. 4 1 1 M35655 THE “D” TERMINAL OPERATES AS AN INPUT FOR DEFROST. ACTIVE INPUT ON “D” TERMINAL WILL POWER AUX1. IF “D” TO AUX1 IS NOT DESIRED, DO NOT CONNECT “D” TERMINAL TO THE ERM5220R. THIS FEATURE IS ONLY ACTIVE WHEN THE THE ERM5220R IS CONFIGURED FOR USE WITH A COMPRESSOR TERMINAL FOR JUMPER. JUMPER BETWEEN J AND R SHOULD BE IN PLACE FOR COMPRESSOR USE. TERMINALS FOR 24VAC POWER. FIRST STAGE OF TWO STAGE COMPRESSOR.
L S1 S1 TERMINAL FOR HEAT CALL. M35656A NOTE: ERM WILL NOT SUPPORT SERIES20 OPERATION. WHEN CONFIGURED AS A BOILER, THE Y RELAY SHALL BE OFF AT ALL TIMES. TERMINAL FOR JUMPER. JUMPER BETWEEN J AND R SHOULD BE REMOVED FOR BOILER USE. TERMINALS FOR 24VAC POWER. TERMINAL FOR HEAT CALL. D O/B T Y C R J 5 Y2 T TERMINALS FOR 10K OHM TEMPERATURE SENSOR. CAN BE USED FOR FREEZE PROTECTION IN THE CASE OF THE THERMOSTAT LOSING THE SIGNAL TO THE ERM.
33-00135EFS_B.book Page 6 Wednesday, November 11, 2015 11:31 AM INSTALLATION IMPORTANT • The ERM is not compatible with RedLink Zone boards. • To ensure that the ERM will receive a wireless signal at the desired installation location, follow steps 1 to 5 in the Wiring section. • If your location has metal siding, the ERM’s signal may be affected. If there is no communication or poor signal strength, consider a different location.
33-00135EFS_B.book Page 7 Wednesday, November 11, 2015 11:31 AM 4. For compressor applications: Leave the jumper between terminals J and R in place. For boiler applications: Remove the jumper between terminals J and R. FOR COMPRESSOR: Jumper J and R J R Y C Y2 T O/B T D L S1 S1 FOR BOILER: Remove Jumper MCR35657 Fig. 5. Terminal Designations showing the jumper between J and R terminals. 5. For compressors and boilers: Connect a 24 VAC power source to the R and C terminals on the ERM.
33-00135EFS_B.book Page 8 Wednesday, November 11, 2015 11:31 AM 6. For compressors and boilers: Put the thermostat in pairing mode by selecting “add a device” from the installer menu. See thermostat manual for further details. Once the thermostat is in pairing mode, press and quickly release the “Connect” button on the ERM. When the ERM is connected to the system, the ERM’s “Connected” LED will be solid green and the thermostat will show “ERM” in its Wireless Manager. (Fig.
33-00135EFS_B.book Page 9 Wednesday, November 11, 2015 11:31 AM BOILER J R 24 VAC V c.a. C Y Y2 T O/B T T T D EQUIPMENT CONTROL BOARD L S1 S1 10K OHM INDOOR TEMPERATURE SENSOR (RECOMMENDED) M35673 Fig. 10. IMPORTANT If the ERM was previously used with a compressor and will now be used with a boiler: 1) un-enroll the ERM at the thermostat; 2) remove the jumper on the ERM; 3) designate Radiant Heat for Heating System Type (ISU 2000) in your thermostat. Mounting ERM 8.
33-00135EFS_B.book Page 10 Wednesday, November 11, 2015 11:31 AM 9. Attach cover and secure with bottom screw (Fig. 13). MOUNTING SCREWS D L S1 S1 CONNECTED LED STATUS Flashing: Device Connecting Green: Device Connected Red: Not Communicating Compressor: Jump J and R Boiler: Remove Jumper Compressor Boiler Connected CONNECTED LED STATUS Flashing: Device Connecting Green: Device Connected Red: Not Communicating INCORRECT MINIMUM 1/4 INCH GAP M35666 Fig. 12.
33-00135EFS_B.book Page 11 Wednesday, November 11, 2015 11:31 AM M35667 Fig. 13.
33-00135EFS_B.book Page 12 Wednesday, November 11, 2015 11:31 AM Checkout Power the system on. Use the thermostat to start a cooling or heating cycle, testing the ERM. 1. 2. 3. 4. 5. 6. Restore power to the compressor/boiler as well as your RedLink system. Raise/lower the set point on the zone thermostat to initiate a call for heat/cooling. Observe all control devices to ensure operation and heat/cooling is active. Lower/raise the set point on the thermostat to suspend the call for heat/cooling.
33-00135EFS_B.book Page 13 Wednesday, November 11, 2015 11:31 AM M35680 Fig. 14.
33-00135EFS_B.book Page 14 Wednesday, November 11, 2015 11:31 AM TROUBLESHOOTING NOTE: Disconnect RedLink™ when making changes to the device. RESET PROCEDURE: Hold down the “Connect” button on the ERM for 10 seconds. The “Connection” LED should appear red for a few seconds and go out. This indicates the unit is reset. Symptom Possible Cause Action Relays don’t switch as Incorrect jumper expected configuration Check jumper configuration.
33-00135EFS_B.book Page 15 Wednesday, November 11, 2015 11:31 AM Symptom Possible Cause Action No wired outdoor No outdoor temperature shown on temperature sensor connected to ERM, or thermostat device configured as boiler Connect outdoor temperature sensor to S1/S1 terminals. Thermostat shows “—” Wired outdoor for outdoor temperature sensor temperature failed Check sensor for short circuit or open circuit.
33-00135EFS_B.book Page 16 Wednesday, November 11, 2015 11:31 AM SPECIFICATIONS Operating Ambient Temperature Range: Compressor: -40 to +155 ºF (-40 to +68 ºC) Boiler: 30 to +130 ºF (-1 to +54 ºC) Operating Relative Humidity Range: 0 - 99 % Electrical: 24 VAC, 50/60 Hz. Dimensions: 175 mm x 168 mm x 38 mm Wireless capability via RedLink™ technology. 6-39/64 (168) 1-31/64 (38) 6-7/8 (175) M35664 Fig. 15. Dimensions.
33-00135EFS_B.book Page 17 Wednesday, November 11, 2015 11:31 AM SEPARABLE PARTS ERM with TH8321R1001/U: YERM5220R8321 ERM with TH8321R1001/U and THM5421R1021: YERM5220RVPEIM FCC REGULATIONS § 15.19 (a)(3) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation.
33-00135EFS_B.book Page 18 Wednesday, November 11, 2015 11:31 AM 5 YEAR WARRANTY Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option).
33-00135EFS_B.
33-00135EFS_B.book Page 20 Wednesday, November 11, 2015 11:31 AM Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 yourhome.honeywell.com ® U.S. Registered Trademark © 2015 Honeywell International Inc. 33-00135EFS—03 M.S.
33-00135EFS_B.book Page 1 Wednesday, November 11, 2015 11:31 AM ERM5220R Module d'équipement à distance (ERM) AVEC TECHNOLOGIE SANS FIL REDLINK™ GUIDE D’INSTALLATION Table des matières À propos du module ERM5220R 2 Liste de vérification pour l’installation 3 Désignations des bornes 4 Installation 6 Vérification 12 Dépannage 14 Caractéristiques 16 Garantie de 5 ans 18 MISE EN GARDE Lire cette notice d'installation dans son intégralité et bien respecter les instructions.
33-00135EFS_B.book Page 2 Wednesday, November 11, 2015 11:31 AM À propos du module ERM5220R THERMOSTAT MODULE ERM FIL UNITÉ DE CONDENSATION MODULE ERM CHAUDIÈRE MFCR35654 Fig. 1. • Communication sans fil RedLink™ entre le unité de condensation/compresseur ou la chaudière et le thermostat. • Élimine la nécessité d'acheminer des fils supplémentaires vers l'équipement, pour la mise à niveau d'une thermopompe par exemple. • Compatible avec une utilisation à l'extérieur.
33-00135EFS_B.book Page 3 Wednesday, November 11, 2015 11:31 AM Liste de vérification pour l’installation MATÉRIEL FOURNI : ERM5220R Equipment Remote Module WITH REDLINK™ WIRELESS TECHNOLOGY INSTALL GUIDE Table of Contents About the ERM5220R Installation Checklist Terminal Designations Installation 2 3 4 6 Checkout 12 Troubleshooting 14 Specifications 16 5 Year Warranty 18 CAUTION Read these installation instructions completely and follow them carefully.
DEUXIÈME ÉTAGE DU COMPRESSEUR À DEUX ÉTAGES. 1 LA BORNE D SERT D'ENTRÉE POUR LE DÉGIVRAGE. L'ENTRÉE ACTIVE SUR LA BORNE D ALIMENTE AUX1. SI CELA N'EST PAS SOUHAITÉ, NE PAS BRANCHER LA BORNE D AU MODULE ERM5220R. CETTE FONCTION N'EST ACTIVE QUE LORSQUE LE MODULE ERM5220R EST CONFIGURÉ POUR UNE UTILISATION AVEC UN COMPRESSEUR. BORNE POUR CAVALIER. LE CAVALIER ENTRE J ET R DOIT ÊTRE EN PLACE POUR L'APPLICATION AVEC COMPRESSEUR. BORNES POUR ALIMENTATION 24 V C.A. PREMIER ÉTAGE DU COMPRESSEUR À DEUX ÉTAGES.
BORNE POUR APPEL DE CHAUFFAGE. REMARQUE : L'ERM N'EST PAS COMPATIBLE AVEC LA SÉRIE 20. POUR LES APPLICATIONS AVEC CHAUDIÈRE, LE RELAIS Y EST DÉSACTIVÉ EN PERMANENCE. BORNE POUR CAVALIER. LE CAVALIER ENTRE J ET R DOIT ÊTRE RETIRÉ POUR L'APPLICATION AVEC CHAUDIÈRE. BORNES POUR ALIMENTATION 24 V C.A. BORNE POUR APPEL DE CHAUFFAGE. MF35656A BORNES POUR CAPTEUR DE TEMPÉRATURE 10 K OHMS. PEUT ÊTRE UTILISÉ POUR LA PROTECTION CONTRE LE GEL EN CAS DE PERTE DE SIGNAL ENTRE LE THERMOSTAT ET LE MODULE ERM.
33-00135EFS_B.book Page 6 Wednesday, November 11, 2015 11:31 AM INSTALLATION IMPORTANT • Le module ERM n'est pas compatible avec les tableaux de zone RedLink. • Pour s'assurer que le module ERM recevra un signal sans fil à l'emplacement souhaité pour l'installation, suivre les étapes 1 à 5 de la section Câblage. • Si l'emplacement comporte un bardage métallique, le signal de l'ERM peut en être affecté. En cas d'absence de communication ou d'intensité insuffisante du signal, considérer un autre emplacement.
33-00135EFS_B.book Page 7 Wednesday, November 11, 2015 11:31 AM 4. Pour les applications avec compresseur : Laisser le cavalier en place entre les bornes J et R. Pour les applications avec chaudière : Retirer le cavalier entre les bornes J et R. FOR COMPRESSOR: Jumper J and R J R Y C Y2 T O/B T D L S1 S1 FOR BOILER: Remove Jumper MCR35657 Fig. 5. Désignations des bornes montrant le cavalier entre les bornes J et R. 5.
33-00135EFS_B.book Page 8 Wednesday, November 11, 2015 11:31 AM 6. Pour les compresseurs et les chaudières : Mettre le thermostat en mode d'appairage en sélectionnant « Add a device » (Ajouter un appareil) dans le menu de l'installateur. Consulter le manuel du thermostat pour plus de détails. Une fois le thermostat en mode d'appairage, appuyer rapidement sur le bouton « Connect » (Connexion) sur le module ERM.
33-00135EFS_B.book Page 9 Wednesday, November 11, 2015 11:31 AM CHAUDIÈRE J 24 V c.a. R C Y Y2 T O/B T T T D TABLEAU DE CONTRÔLE DE L'ÉQUIPEMENT L S1 S1 CAPTEUR DE TEMPÉRATURE INTÉRIEURE 10 K OHMS (RECOMMANDÉ) MF35673 Fig. 10.
33-00135EFS_B.book Page 10 Wednesday, November 11, 2015 11:31 AM 9. Attacher le couvercle et le fixer avec la vis inférieure (Fig. 13).
33-00135EFS_B.book Page 11 Wednesday, November 11, 2015 11:31 AM M35667 Fig. 13.
33-00135EFS_B.book Page 12 Wednesday, November 11, 2015 11:31 AM Vérification Mettre le système sous tension. Utiliser le thermostat pour lancer un cycle de chauffage ou de refroidissement pour tester le module ERM. 1. 2. 3. 4. 5. 6. Restaurer l'alimentation vers le compresseur/la chaudière ainsi que vers le système RedLink. Hausser/réduire le point de consigne sur le thermostat de zone pour lancer un appel de chauffage/refroidissement.
-00135EFS_B.book Page 13 Wednesday, November 11, 2015 11:31 AM M35680 Fig. 14.
33-00135EFS_B.book Page 14 Wednesday, November 11, 2015 11:31 AM DÉPANNAGE REMARQUE : Débrancher le système RedLink™ avant de procéder à des modifications sur le dispositif. PROCÉDURE DE RÉINTIALISATION : Appuyer pendant 10 secondes sur le bouton « Connect » (Connexion) du module ERM. Le témoin DEL de connexion doit s'allumer en rouge pendant quelques secondes, puis s'éteindre. Ceci indique que l'unité a été réinitialisée.
33-00135EFS_B.book Page 15 Wednesday, November 11, 2015 11:31 AM Symptôme Cause possible Action Le thermostat n'affiche pas la température extérieure Aucun capteur de température extérieure n'est connecté au module ERM, ou l'appareil est configuré sur chaudière Brancher le capteur de température extérieur aux bornes S1/S1.
33-00135EFS_B.book Page 16 Wednesday, November 11, 2015 11:31 AM CARACTÉRISTIQUES Gamme de température ambiante de service : Compresseur : -40 à +68 °C (-40 à +155 °F) Chaudière : -1 à +54 °C (30 à +130 °F) Plage d'humidité relative de service : 0 - 99 % Spécifications électriques : 24 V c.a., 50/60 Hz. Dimensions : 175 mm x 168 mm x 38 mm Capacité sans fil via technologie RedLink™. 6-39/64 (168) 1-31/64 (38) 6-7/8 (175) M35664 Fig. 15. Dimensions.
33-00135EFS_B.book Page 17 Wednesday, November 11, 2015 11:31 AM PIÈCES SÉPARABLES ERM avec TH8321R1001/U : YERM5220R8321 ERM avec TH8321R1001/U et THM5421R1021 : YERM5220RVPEIM RÈGLEMENTS DE LA FCC § 15.19 (a)(3) Ce dispositif est conforme à la Partie 15 du règlement de la FCC. Le fonctionnement est soumis aux deux conditions suivantes : 1. Ce dispositif ne doit pas causer d’interférences nuisibles, et 2.
33-00135EFS_B.book Page 18 Wednesday, November 11, 2015 11:31 AM GARANTIE DE 5 ANS Honeywell garantit ce produit contre tout vice de fabrication ou de matériau dans la mesure où il en est fait une utilisation et un entretien convenables, et ce, pour cinq (5) ans à partir de la date d’achat par le consommateur. En cas de défaillance ou de mauvais fonctionnement pendant la période de garantie, Honeywell remplacera ou réparera le produit (à sa discrétion).
33-00135EFS_B.
33-00135EFS_B.book Page 20 Wednesday, November 11, 2015 11:31 AM Solutions de régulation et d'automatisation Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 yourhome.honeywell.com ® Marque de commerce déposée aux États-Unis © 2015 Honeywell International Inc. 33-00135EFS—03 M.S.
33-00135EFS_B.book Page 1 Wednesday, November 11, 2015 11:31 AM Módulo de acceso remoto al equipo ERM5220R CON TECNOLOGÍA INALÁMBRICA REDLINK™ GUÍA DE INSTALACIÓN Índice Sobre el ERM5220R 2 Lista de verificación para la instalación 3 Designación de los terminales: 4 Instalación 6 Verificación 12 Localización y solución de problemas 14 Especificaciones 16 Garantía de 5 Años 19 PRECAUCIÓN Lea todas las instrucciones de instalación y cumpla con estas atentamente.
33-00135EFS_B.book Page 2 Wednesday, November 11, 2015 11:31 AM Sobre el ERM5220R TERMOSTATO ERM CABLE UNIDAD DE CONDENSACIÓN ERM CALDERA MSCR35654 Fig. 1. • Comunicación inalámbrica RedLink™ entre el unidad de condensación/compresor o la caldera y el termostato. • Elimina la necesidad de pasar cables adicionales a su equipo, por ejemplo, durante una actualización de la bomba de calor. • Apto para uso exterior.
33-00135EFS_B.book Page 3 Wednesday, November 11, 2015 11:31 AM Lista de verificación para la instalación MATERIALES PROPORCIONADOS: ERM5220R Equipment Remote Module WITH REDLINK™ WIRELESS TECHNOLOGY INSTALL GUIDE Table of Contents About the ERM5220R Installation Checklist Terminal Designations Installation 2 3 4 6 Checkout 12 Troubleshooting 14 Specifications 16 5 Year Warranty 18 CAUTION Read these installation instructions completely and follow them carefully.
4 1 EL TERMINAL "D" FUNCIONA COMO UNA ENTRADA PARA DESCONGELACIÓN. ACTIVAR LA ENTRADA EN EL TERMINAL "D" ALIMENTARÁ EL AUX1. SI NO SE DESEA "D" A AUX1, NO CONECTE EL TERMINAL "D" AL ERM5220R. ESTA FUNCIÓN ESTÁ ACTIVA ÚNICAMENTE CUANDO EL ERM5220R ESTÁ CONFIGURADO PARA USO CON UN COMPRESOR. TERMINAL DEL PUENTE. EL PUENTE ENTRE J Y R DEBE ESTAR EN SU LUGAR PARA EL USO DEL COMPRESOR. TERMINALES PARA ALIMENTACIÓN DE 24 V CA. PRIMERA ETAPA DEL COMPRESOR DE DOS ETAPAS.
S1 S1 L TERMINAL PARA DEMANDA DE CALEFACCIÓN. NOTA: EL ERM NO ADMITE EL FUNCIONAMIENTO CON LA SERIE 20. CUANDO SE CONFIGURA COMO UNA CALDERA, EL RELÉ "Y" DEBE ESTAR APAGADO EN TODO MOMENTO. TERMINAL PARA EL PUENTE. EL PUENTE ENTRE J Y R DEBE ESTAR EN SU LUGAR PARA EL USO DE LA CALDERA. TERMINALES PARA ALIMENTACIÓN DE 24 V CA. TERMINAL PARA DEMANDA DE CALEFACCIÓN. D O/B T Y C R J 5 Y2 T MS35656A TERMINALES PARA EL SENSOR DE TEMPERATURA DE 10K OHMIOS.
33-00135EFS_B.book Page 6 Wednesday, November 11, 2015 11:31 AM INSTALACIÓN IMPORTANTE • El módulo de acceso remoto al equipo (ERM) no es compatible con los tableros de zona RedLink. • Para garantizar que el ERM reciba una señal inalámbrica en el lugar de instalación deseado, siga los pasos 1 al 5 en la sección de Cableado. • Si el lugar tiene paneles de revestimiento de metal, la señal del ERM puede verse afectada. Si no hay comunicación o la señal tiene poca potencia, considere una ubicación diferente.
33-00135EFS_B.book Page 7 Wednesday, November 11, 2015 11:31 AM 4. Para aplicaciones en el compresor: Deje el puente entre los terminales J y R en su lugar. Para aplicaciones en la caldera: Retire el puente entre los terminales J y R. FOR COMPRESSOR: Jumper J and R J R Y C Y2 T O/B T D L S1 S1 FOR BOILER: Remove Jumper MCR35657 Fig. 5. Designaciones de terminales mostrando el puente entre los terminales J y R. 5.
33-00135EFS_B.book Page 8 Wednesday, November 11, 2015 11:31 AM 6. Para compresores y calderas: Coloque el termostato en el modo de conexión seleccionando "añada un dispositivo" del menú del instalador. Para obtener información más detallada, consulte el manual del termostato. Una vez que el termostato esté en el modo de conexión, presione y suelte rápidamente el botón "Conectar" en el ERM.
33-00135EFS_B.book Page 9 Wednesday, November 11, 2015 11:31 AM CALDERA J R C 24 VAC V c.a. Y Y2 T O/B T T T D PANEL DE CONTROL DEL EQUIPO L S1 S1 SENSOR DE 10K OHM DE TEMPERATURA INTERIOR (RECOMENDADO) MS35673 Fig. 10.
33-00135EFS_B.book Page 10 Wednesday, November 11, 2015 11:31 AM 9. Fije la cubierta y asegúrela con el tornillo inferior (Fig. 13).
33-00135EFS_B.book Page 11 Wednesday, November 11, 2015 11:31 AM M35667 Fig. 13.
33-00135EFS_B.book Page 12 Wednesday, November 11, 2015 11:31 AM Verificación Active el suministro de energía eléctrica hacia el sistema. Utilice el termostato para comenzar el ciclo de refrigeración o calefacción, probando el ERM. 1. 2. 3. 4. 5. 6. Restituya el suministro de energía eléctrica al compresor/caldera así como al sistema RedLink. Eleve/baje el punto de referencia del termostato de zona para iniciar una demanda de calefacción/refrigeración.
33-00135EFS_B.book Page 13 Wednesday, November 11, 2015 11:31 AM M35680 Fig. 14.
33-00135EFS_B.book Page 14 Wednesday, November 11, 2015 11:31 AM LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS NOTA: Desconecte RedLink™ cuando haga cambios al dispositivo. PROCEDIMIENTO PARA REINICIAR: Presione el botón "Connect" (conectar) en el ERM durante 10 segundos. El LED de la "conexión" debe aparecer en rojo durante unos segundos y después se apaga. Esto indica que la unidad está reiniciada. Causa posible Acción Los relés no cambian como se espera Síntoma Configuración incorrecta del puente.
33-00135EFS_B.book Page 15 Wednesday, November 11, 2015 11:31 AM Síntoma Causa posible No hay sensor de No se muestra la temperatura exterior temperatura de exterior cableado en el termostato conectado al ERM, ni dispositivo configurado como caldera Acción Conecte el sensor de temperatura exterior a los terminales S1/S1. El dispositivo solo reporta la temperatura exterior cuando está configurado como compresor.
33-00135EFS_B.book Page 16 Wednesday, November 11, 2015 11:31 AM ESPECIFICACIONES Rango de temperatura ambiente de funcionamiento: Compresor: De -40 a +155 °F (-40 a +68 °C) Caldera: De 30 a +130 ºF (-1 a +54 ºC) Rango de humedad relativa de funcionamiento: 0 - 99 % Características eléctricas: 24 V CA, 50/60 Hz. Dimensiones: 175 mm x 168 mm x 38 mm Habilitación inalámbrica mediante la tecnología RedLink™. 6-39/64 (168) 1-31/64 (38) 6-7/8 (175) M35664 Fig. 15. Dimensiones.
33-00135EFS_B.
33-00135EFS_B.book Page 18 Wednesday, November 11, 2015 11:31 AM REGULACIONES DE LA FCC § 15.19 (a)(3) Este dispositivo cumple con la Sección 15 de las regulaciones la FCC. El funcionamiento está sujeto a las dos condiciones siguientes: 1. Este dispositivo no debe causar interferencia perjudicial y 2. este dispositivo deberá aceptar cualquier interferencia que se reciba, incluyendo la interferencia que pudiese causar el funcionamiento no deseado.
33-00135EFS_B.book Page 19 Wednesday, November 11, 2015 11:31 AM GARANTÍA DE 5 AÑOS Honeywell garantiza que este producto no tiene defectos en la mano de obra ni en los materiales en condiciones de uso y servicio normales durante un período de cinco (5) años desde la fecha de compra por parte del consumidor.