Brochure

63-8702 85
Motorized Zone Valves
VU443, VU444; VU843, VU844 Fan Coil Actuators
592 70-6910
Fan Coil Actuators
VU443, VU444; VU843; VU844 Fan Coil Actuators
Humidity resistant fan coil valve actuators are used in conjunction
with VU52, VU53 and VU54 valves for controlling the ow of hot
or chilled water in commercial HVAC equipment such as fan coil
units, terminal reheat coils and convectors.
Compact construction for easy installation.
Fits under the cover of most baseboard convectors with actuator
tted to valve body.
One-button, quick release. Secure 3-point, metal latch to valve body.
Spring return operation.
Stainless steel case and aluminum cover. Rust-proof nickel-plated
motors available.
Line or low voltage, rust-resistant motors.
Manual opener for installation and valve operation on power failure.
Valve returns to automatic position when power is restored.
Actuator may be reinstalled or serviced without draining the system
or disassembling the valve.
Slotted conduit hole for faster wiring.
Dimensions in inches (millimeters)
2
2
1
1
VU53 VALVE WITH VU448 ACTUATOR
VU53 AND VU54 VALVE WITH ACTUATOR
VU5 ACTUATOR
2-3/8
(60)
7/8 DIA.
(22)
1-1/2
(38)
3-3/4
(133)
15/32
(12)
3/8
(10)
1-3/4
(44)
1-3/4
(44)
A
A
B
AB
7
3/8
(10)
A
2-1/8 (54)
(INVERTED
FLARE)
1-3/4
(44)
1-3/4
(44)
B
3-WAY
7/8 (22)
2-WAY
VALVE BODY SIZE A B
1/2 IN. SWEAT 1-5/6 (33) 1-5/6 (33)
3/4 IN. SWEAT 1-3/8 (35) 1-11/16 (43)
1 IN. SWEAT 1-11/16 (43) 1-11/16 (43)
1/2 IN. NPT 1-3/8 (35) 1-5/16 (33)
3/4 IN. NPT 1-11/16 (43) 1-7/16 (37)
1 IN. NPT 1-11/16 (43) 1-7/16 (37)
HEIGHT NEEDED TO REMOVE ACTUATOR OR COVER
OPENING FOR 1/2 IN. CONDUIT ON OPPOSITE SITE OF
MANUAL LEVER FOR ALL MODELS.
M18261A
Application: For controlling the ow of hot or chilled water in
commercial HVAC equipment such as fan coil units, terminal reheat
coils and convectors
Actuator Type: Valve
Control Signal: Two position; SPST
Fail Safe Mode: Spring Return
Electrical Connections: Leads
Power Consumption: Driving – 6 Watts
Timing, Nominal: Driving @ 60 Hz (sec) – 15 sec maximum
Maximum Differential Pressure Ratings (Close-off) (psi): Depends
on Cv rating of valve
Manual operation: Lever
Approximate, Dimensions: 2 3/8 in. high, 3 1/2 in. wide, 2 3/8 in. wide
(62 mm high, 88 mm wide, 60 mm deep)
Ambient Temperature Range: 34°F to 125°F ambient at 200°F Fluid
(1°C to 52°C ambient at 93°C Fluid)
Approvals, CSA: Certied C/US File No. LR1322
Fluid Temperature: 200°F (94°C)
Material
Number
Frequency Internal
Auxiliary
Switch
Stroke Spring Return
Timing
Materials Supply
Voltage
Electrical
Connections
Size
Comments Used With
VU443A1008/U 60 Hz 0 22 deg. Nominal – 4 sec Stainless Case,
Aluminum Cover
120V 6 in. (0.15 m) 2-way NC VU valve body
(VU53)
VU443A1024/U 60 Hz 0 22 deg. Nominal – 4 sec Stainless Case,
Aluminum Cover
208V 18 in. (0.5 m) 2-way NC VU valve body
(VU53)
VU443A1057/U 60 Hz 0 22 deg. Nominal – 4 sec Stainless Case,
Aluminum Cover
277V 18 in. (0.5 m) 2-way NC VU valve body
(VU53)
VU443A1115/U 50 Hz;
60 Hz
0 22 deg. Nominal – 4 sec Stainless Case,
Aluminum Cover
230V 6 in. (0.15 m) 2-way NC VU valve body
(VU53)
VU444A1007/U 60 Hz 0 45 deg. Nominal – 6 sec Stainless Case,
Aluminum Cover
120V 6 in. (0.15 m) 2-way NO (VU52) or 3-way
VU valve body (VU54)
VU444A1098/U 60 Hz 0 45 deg. Nominal – 6 sec Stainless Case,
Aluminum Cover
277V 18 in. (0.5 m) 2-way NO (VU52) or 3-way
VU valve body (VU54)