Brochure

63-8702 51
Aquastat
®
Controllers
Material Number Application Switching Action Operating
Temperature
Range
Differential
Temperature
Well Spud Size Capillary Length Mounting Includes
L4006B1155/U Circulator SPST, contacts make
on temperature rise.
100°F to 240°F
(38°C to 116°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
3 in. (76 mm) Horizontal or
Vertical
Stop factory-set at
240°F (116°C); Heat-
conductive compound
L4006B1163/U Circulator SPST, contacts make
on temperature rise.
100°F to 240°F
(38°C to 116°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
3 in. (76 mm) Horizontal or
Vertical
L4006E1067/U High Limit;
Manual Reset
SPST, contacts break
on temperature rise.
130°F to 270°F
(54°C to 132°C)
Manual Reset 3 in. (76 mm) Horizontal or
Vertical
Heat-conductive
compound; Stop
factory-set at 250°F
(121°C); Well adapter
L4006E1091/U High Limit;
Manual Reset
SPST, contacts break
on temperature rise.
130°F to 270°F
(54°C to 132°C)
Manual Reset 3 in. (76 mm) Horizontal or
Vertical
L4006E1109/U High Limit;
Manual Reset
SPST, contacts break
on temperature rise.
130°F to 270°F
(54°C to 132°C)
Manual Reset 1 1/2 in. to
3 in. (38 mm to
76 mm)
Horizontal or
Vertical
L4006E1117/U High Limit;
Manual Reset
SPST, contacts break
on temperature rise.
100°F to 240°F
(38°C to 116°C)
Manual Reset 3/4 in. - 14 NPT
(19 mm - 14
NPT)
1 1/2 in.
(38 mm)
Horizontal or
Vertical
3/4 in. well - 123870A
L4006E1125/U High Limit;
Manual Reset
SPST, contacts break
on temperature rise.
100°F to 200°F
(38°C to 93°C)
Manual Reset 3 in. (76 mm) Horizontal or
Vertical
L4006H1004/U High Limit; strap-
on mounting on
well mount.
SPST, contacts break
on temperature rise.
100°F to 240°F
(38°C to 116°C)
Manual Reset 1 1/2 in.
(38 mm)
Horizontal or
Vertical
Bracket for strap-on
mounting; Heat-
conductive compound;
Stop factory-set at
240°F (116°C)
L6006A1012/U Circulator Control
and High Limit or
Low Limit
SPDT 100°F to 240°F
(38°C to 116°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
1/2 in. (13 mm) 1 1/2 in.
(38 mm)
Horizontal or
Vertical
1/2 in. well - 123869A
L6006A1145/U Circulator Control
and High Limit or
Low Limit
SPDT 100°F to 240°F
(38°C to 116°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
3 in. (76 mm) Horizontal Stop factory-set at
240°F (116°C); Heat-
conductive compound
L6006A1244/U Circulator Control
and High Limit or
Low Limit
SPDT 100°F to 240°F
(38°C to 116°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
3 in. (76 mm) Horizontal or
Vertical
L6006C1018/U Circulator Control
and High Limit
and Low Limit
SPDT 65°F to 200°F
(18°C to 93°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
Horizontal or
Vertical Surface
mounting
Stop factory-set at
200°F (93°C)
L6006C1034/U Circulator and
High and Low
Limit
SPDT 65°F to 200°F
(18°C to 93°C)
5°F to 30°F
adj. (3°C to
17°C adj.)
Horizontal or
Vertical Surface
mounting