Brochure
63-8702 15
Pressure Regulating Valve
DS06-JK-10-LF Jumper Kit
Commonly used in residential and commercial new construction,
Jumper Kits serve as a temporary place holder for Pressure Reducing
Valves in potable water systems. Using a Jumper Kit ensures Pressure
Reducing Valves are not vandalized or stolen from unsecured or open
job sites. Additionally, the Jumper Kit allows plumbing and piping to
be tested for leaks as well flushed prior to the installation of Pressure
Reducing Valves.
The DS06-JK-10*-LF Jumper Kits are compatible with both the DS06
and FK06 Pressure Reducing Valves.
Model: DS06-JK-10*-LF
Medium: Water
Filter Mechanism: Stainless steel fine filter mesh
Operating Pressure @ 73F1: 250 PSI
Fluid Temperature (Maximum): 140°F
Ambient Temperature Range: 33°F to 140°F
Union Nut and Tailpiece Material: Brass
Strainer Material: Stainless Steel w/ EPDM Rubber
Plastic Tube Material: PVC
Gasket Material: EPDM/NB
Material Number Pipe Size Connection Type Description Order Quantities
DS06-JK-101-LF/B 3/4” Union Sweat 3/4” Jumper Kit; Pipe, Unions, Tailpiece, Strainer 24
DS06-JK-102-LF/B 1” Union Sweat 1” Jumper Kit; Pipe, Unions, Tailpiece, Strainer 24
DS06-JK-103-LF/B 1-1/4” Union Sweat 1-1/4” Jumper Kit; Pipe, Unions, Tailpiece, Strainer 8
DS06-JK-104-LF/B 1-1/2” Union Sweat 1-1/2” Jumper Kit; Pipe, Unions, Tailpiece, Strainer 8