Brochure
118 63-8702
Thermostatic Radiator Valves and Actuators
V200; V2000 Series Standard Capacity Thermostatic Radiator Valves
Body
V200LD
V2040A, V2040E
(Straight body)
V2040D
V2040E
(Angle body)
One-Pipe Steam Thermostatic Radiator Valves - Allow automatic
temperature control in one-pipe steam or hot water systems for free
standing radiators, convectors and other heating units with standard
capacity requirements.
• Continually monitors and adjusts room temperature for consistent
comfort and relief from under-heating and overheating.
• Adjustable balancing cartridge design made from resilient material
(EPDM), ensures tight shut-off on steam and hot water systems.
• Nickel plated brass casted body.
• Replaceable cartridge for easy service with service tool.
• Controls include valve body, steam air vent.
• Used with T100 set point and capillary actuators.
• No electrical connection required for non-electric actuators.
• Normally open without control mounted.
Capacity: Standard
Temperature Range: 248°F Maximum (120°C Maximum)
Materials (Body): Nickel Plated Bronze
Cartridge Change Tool: Yes - Use VA8200A001
Pressure Ratings (psi): Hot Water – 150 psi maximum; Steam – 15 psi
maximum
Pressure Ratings (kPa): Hot Water – 1034 kPa maximum; Steam –
103 kPa
Maximum Differential Pressure Ratings (Close-off) (psi): With T100 or
T200: 15 psi, With MV100: 36 psi, For low noise: 3 psi
Maximum Differential Pressure Ratings (Close-off) (kPa): With T100
or T200: 103 kPa, With MV100: 248 kPa, For low noise: 20 kPa
Material
Number
Application Pipe Size
(inch)
Pipe Size
(DN)
Body Pattern Capacity
(Cv)
Capacity
(Btu / hr - steam)
Connection Type Connection
Size
Used With
V200LDSL15 For baseboards and
other installations with
copper tubing.
1/2 in. DN15 Straight 2.5 Cv 59,100 Btu/hr Inlet – NPT; Outlet
– Sweat both
ends, no union
1/2 in. T100
V200LDSL20 3/4 in. DN20 Straight 2.7 Cv 63,800 Btu/hr Inlet – NPT; Outlet
– Sweat both
ends, no union
3/4 in. T100
V2040ASL15 Replaces most manual
valves with minimum
piping changes.
1/2 in. DN15 Horizontal Angle 2.5 Cv 59,100 Btu/hr Inlet – NPT; Outlet
– Threaded
1/2 in. T100A, M and V controls
to conform to horizontal
mounting requirements
V2040ASL20 3/4 in. DN20 Horizontal Angle 2.7 Cv 63,800 Btu/hr Inlet – NPT; Outlet
– Threaded
3/4 in. T100A, M and V controls
to conform to horizontal
mounting requirements
V2040ASL25 1 in. DN25 Horizontal Angle 2.7 Cv 70,500 Btu/hr Inlet – NPT; Outlet
– Threaded
1 in. T100A, M and V controls
to conform to horizontal
mounting requirements
V2040DSL15 Especially suited
for baseboards and
straight runs where
manual valves were
not originally installed.
1/2 in. DN15 Straight 2.5 Cv 59,100 Btu/hr Inlet – NPT; Outlet
– Threaded
1/2 in.
V2040DSL20 3/4 in. DN20 Straight 2.7 Cv 63,800 Btu/hr Inlet – NPT; Outlet
– Threaded
3/4 in.
V2040DSL25 1 in. DN25 Straight 2.7 Cv 70,500 Btu/hr Inlet – NPT; Outlet
– Threaded
1 in.
V2040ESL15 Use where installation
space is limited
1/2 in. DN15 Angle 2.5 Cv 59,100 Btu/hr Inlet – NPT; Outlet
– Threaded
1/2 in. T100C, T100B, T100F
V2040ESL20 3/4 in. DN20 Angle 2.7 Cv 63,800 Btu/hr Inlet – NPT; Outlet
– Threaded
3/4 in. T100C, T100B, T100F
V2040ESL25 1 in. DN25 Angle 2.7 Cv 70,500 Btu/hr Inlet – NPT; Outlet
– Threaded
1 in. T100C, T100B, T100F