WHOLE HOME WATER SOLUTIONS Hydronic Heating and Potable Water Products From hydronic heating controls to mixing valves, Resideo Water Solutions are designed with both customer and contractor satisfaction in mind. Reliable and easy to install, our products are engineered for accuracy and safety.
Resideo Hydronic Solutions Resideo makes a wide variety of controls for hydronic systems. This concept drawing shows various components that can be used in zoned hydronic systems.
Table of Contents Model Index.......................................................................iv Subject Index......................................................................v Potable Water Products Mixing Valves.....................................................................1 Pressure Regulating Valve...............................................12 Water Sediment Filters.....................................................16 Water Heater Gas Valves.......................................
Model Index A R AM-1 Series ..........62-3098............................. 1 AMX Series ...........62-3074............................. 5 AMX300 Series .....63-9876............................. 7 AQ1000TN2 ..........63-9379...........................40 AQ1000TP2 ....... 69-2245EF.........................40 AQ2000..................63-9686...........................41 AQ250....................68-0306...........................37 AQ255....................69-1981...........................38 AQ257............
Subject Index A Accessories AQUATROL 41 Mixing Valves 3 RedLINK Enabled Thermostats 25 Water Filters 17 Actuators Thermostatic Radiator 116 Air Eliminators 101, 102 Air Purger 100 Air Vents and Eliminators 97–103 AquaPUMP Hydronic Circulating Pump 92–95 Aquastat Controllers 50–64 Automatic Air Vent for Heating System 99 Automatic Air Vent for Non-Heating System 98 Automatic Backwash Control 17 B Backflow Preventers with Intermediate Atmospheric Vent 107 Boiler Control Panel for Hydronic Zoning 37 Boiler Fi
Subject Index V Valve Bodies Cross Reference 117 Valves Boiler Fill 106 Diverting 10, 83, 84 Fan Coil Valves 85, 86 Mixing 1–10 Pressure Regulating 12 Thermostatic Mixing 113 Valves for Steam Low Voltage Normally Open 74 VisionPRO® 8000 with RedLINK® technology 24 W Water Filters 16 Water Heater Gas Valves 18 Well Assemblies 65 Wireless Adapter, RedLINK 28 Wireless Indoor Air Sensor 27 Wireless Outdoor Sensor 26 Z Zone Valves Line Voltage 72 Low Voltage Normally Closed 75, 78 Low Voltage Normally Open 80
Mixing Valves AM-1 Series Thermostatic Mixing Valve NPT PEX Sweat ProPress CPVC AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. While increasing the amount of safe, usable hot water, it efficiently offers anti-scald, anti-chill protection.
Mixing Valves Material Number Pipe Size in/(DN) Connection Type Capacity Operating Temperature °F (°C) (Cv) Approvals, ASSE Comments AM101C1070UCPVC1LF AM101C1070-UP-1LF AM101C1070-UPEX1LF AM101C1070-US-1LF AM101C1070-UT-1LF AM101C-1LF/U AM101C-UP-1LF/U AM101C-UCPVC-1LF/U AM101C-UPEX-1LF/U AM101C-US-1LF/U AM101C-UT-1LF/U AM101R-UP-1/U AM101R-UPEX-1/U AM101R-US-1/U AM101R-UT-1/U AM101-SB-1LF/U AM101-UCPVC-1LF/U AM101-UP-1LF/U AM101-UPEX-1LF/U AM101-US-1LF/U AM101-UT-1LF/U AM102-1LF/U AM102-UP-1LF/U AM1
Mixing Valves Mixing Valve Accessories Material Number Pipe Size in/(DN) Connection Type Operating Temperature °F (°C) Description Comments AM08-024LF/U AM08-025LF/U AM08-026LF/U AM08-039LF/U AM08-040LF/U AM08-041LF/U AM08-042LF/U AM08-043LF/U AM09-061LF/U AM09-062LF/U AM09-063LF/U AM100-SB/U AM101-SB/U AM102-SB/U AM206-003LF/U AM206-004LF/U AM206-039/U 1/2 in. (DN15) 3/4 in. (DN20) 1 in. (DN25) 3/4 in. (DN20) 1 in. (DN25) 1/2 in. (DN15) 3/4 in. (DN20) 1 in. (DN25) 1/2 in. (DN15) 3/4 in. (DN20) 1 in.
Mixing Valves Material Number Pipe Size in/(DN) AM-1-020RP/U AM-1-025RP/U AM-1-030RP/U Connection Type Operating Temperature °F (°C) Description 80°F to 120°F (C Range); 60°F to 100°F (B Range) (15°C to 38°C (C Range); 27°C to 49°C (B Range)) 70°F to 145°F (21°C to 63°C) 70°F to 120°F (21°C to 49°C) AM-1 Series B or C Range Element, Spring, Diffuser, and plug assembly AMCU-001RP/U 70°F to 120°F (21°C to 49°C) AMCU100/U 70°F to 120°F (21°C to 49°C) AMU200-RP/U 4 Comments Thermostatic Element Re
Mixing Valves AMX Series DirectConnect Thermostatic Mixing Valves AMX series DirectConnect reduces water heater installation time as the cold and hot port position eliminates the need for typical elbows and tees. Designed for safety to prevent scalding, it also increases user comfort.
Mixing Valves Thermostatic Replacement Mixing Valve Installation AM-1 SERIES CONNECTION AMX SERIES DIRECTCONNECT CONNECTION AMX 300 SERIES DIRECTCONNECT CONNECTION M31168 Capacity (Cv) Operating Temperature °F (°C) Comments Includes 1/2 in. (DN15) Union CPVC, 3/4 in. Bottom 4 Cv 90°F to 130°F (32°C to 54°C) Low lead Content <.25% by weighted average Check valves on hot and cold ports AMX100-UPEX-1LF/U 1/2 in. (DN15) Union PEX, 3/4 in.
Mixing Valves AMX300 Series DirectConnect Thermostatic Mixing Valve and Kits AMX300 series DirectConnect kits reduce installation time while providing industry-leading mixing valve technology, which offers excellent temperature stability and control and minimizes scalding risk to building occupants.
Mixing Valves AMX Series DirectConnect Replacement Part Material Number Operating Temperature °F (°C) Description AMX-001RP/U 90°F to 130°F (32°C to 54°C) AM-1-025RP/U 90°F to 130°F (32°C to 54°C) AMX element, spring, plug assembly. For AMX100 series valves. Thermal element, spring, and plug assembly; Rebuild kit for AM-1 “Standard” (70 -145°F; 21-49°C) series and AMX300 series valves 3/4 in. mixing valve (Replacement valve tor AMX300T and AMX302T DirectConnect mixing valve kits.
Mixing Valves UMV500-LF/U Series UnderSink Thermostatic Mixing Valve The UMV500-LF/U Series UnderSink Thermostatic Mixing Valve is intended for use in under counter and under sink applications. The UMV500-LF/U Universal Model is designed to be used as a three port design (touchless sink) or a four port design (two handle sink) with the addition of the 4 port adaptor (supplied with UMV500-LF/U). The UMV500-LF/U is used to prevent accidental scalding.
Mixing Valves MX Series Large Flow Proportional Mixing or Diverting Valve The MX Series is a state-of-the-art mixing valve that manages the hot and cold supply based on control settings. Accurate control of temperature provides energy savings, increased comfort and safety. The Teflon wear surfaces prevent calcium buildup. • Dual purpose mixing or diverting valve. • Constant water temperature under different operating conditions. • Proportional valve (control of hot and cold water).
Mixing Valves 3" /2" MX MX 2- 1 /2" 2" MX 1- 1 1- 1 MX 1" MX 25 MX /4" Pressure Drop Chart 20 PRESSURE DROP (PSI) 15 10 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.5 2.0 1.5 1.0 0.7 0.6 0.5 0.4 0.3 0.25 0.2 0.15 0.1 0.09 0.08 Material Number Pipe Size in/(DN) MX127LF/U 1 in. (DN25) 0.4 0.5 0.7 0.9 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 7.0 9.0 8.
Pressure Regulating Valve DS06 “DialSet” Low Lead Pressure Regulating Valve With the DialSet Pressure Regulating Valve, you don’t need a pressure gauge. The built-in adjustment dial eliminates the need for a gauge when adjusting the static pressure setting, but there is also an easily accessible gauge port on either side if you need it. This product has the capability to be installed by one individual and the reliability that helps to increase your profits through fewer callbacks.
Pressure Regulating Valve Material Number Pipe Size in/(DN) Connection Type Operating Temperature °F (°C) Description DS06-104-DUS-LF/U 1 1/2 in. (DN40) DS06-104-DUT-LF/U 1 1/2 in. (DN40) DS06-104-LF/U 1-1/2 in. (DN40) DS06-104-SUS-LF/U 1 1/2 in. (DN40) DS06-104-SUT-LF/U 1 1/2 in. (DN40) DS06-105-DUS-LF/U 2 in. (DN50) DS06-105-DUT-LF/U 2 in. (DN50) DS06-105-SUS-LF/U 2 in. (DN50) DS06-105-SUT-LF/U 2 in.
Pressure Regulating Valve DS06LF Pressure Regulating Valves—Repair Parts Material Number Description D06FA-1/2 D06FA-11/2 D06FA-1B ES06F-1/2A ES06F-11/2A ES06F-1B SB06T-1 SB06T-1/2 SB06T-11/2 DS06 Low-Lead Replacement Parts 1/2" & 3/4" Valve Insert without Filter DS06 Low-Lead Replacement Parts 1 1/2" & 2" Valve Insert without Filter DS06 Low-Lead Replacement Parts 1" & 1 1/4" Valve Insert without Filter DS06 Low-Lead Replacement Parts 1/2" & 3/4" Replacement Filter Insert DS06 Low-Lead Replacement Parts
Pressure Regulating Valve DS06-JK-10-LF Jumper Kit Commonly used in residential and commercial new construction, Jumper Kits serve as a temporary place holder for Pressure Reducing Valves in potable water systems. Using a Jumper Kit ensures Pressure Reducing Valves are not vandalized or stolen from unsecured or open job sites. Additionally, the Jumper Kit allows plumbing and piping to be tested for leaks as well flushed prior to the installation of Pressure Reducing Valves.
Water Sediment Filters F76 Water Filters High flow capacity water filter used to remove sediment and debris from residential or commercial water systems. • Ideally suited for sediment removal applications that would quickly plug and restrict the flow of normal filters. • Used as a prefilter, the F76 protects elements of the water system, including specialized treatment devices or other common fixtures and appliances.
Water Sediment Filters MV876 Automatic Backwash Control Backwash Intervals and Selection: 16 intervals from 4 min to 3 months, field adjustable via keypad Display: Digital Approximate Dimensions: 6 in. high, 2-3/4 in wide, 6-5/16 in. deep (152 mm high, 70 mm wide, 160 mm deep) The MV876B Automatic-Backwash Control is available as an accessory. This control is fitted to the drain valve and is programmed by the user to automatically perform the backwash function according to the desired interval.
Water Heater Gas Valves WT88 Series Gas Water Heater Control With Resideo Water Heater Controls, only eight models are needed to replace multiple A.O. Smith, Bradford White, and Rheem controls. Consolidate your inventory while expanding your sales opportunities and capturing more business. Application The WT88xx Water Heater Control is designed for use in Standing Pilot applications using an immersion well for water temperature sensing.
Water Leak and Freeze Detector Water Leak and Freeze Detector The average water leak causes $7000 in damage*. The Water Leak and Freeze Detector can detect water with sensors on base of unit or has expanded coverage with included 5 ft. water sensing cable. Entire cable detects water. • Conveniently place near sinks, washers, water heaters, sump pumps–anywhere leaks could happen. Battery life lasts up to 3 years without incident, depending on usage.
T10 Thermostat T10 Pro Smart Thermostat with RedLINK® The T10 Smart thermostat with RedLINK® features an effortless, 7-Day programmable touchscreen thermostat. Program it based on the homeowners’ schedule, or let it adapt to their life as plans change. Homeowners can adjust it from anywhere using a smartphone or tablet, ensuring maximum comfort when at home and energy savings whether they are home or away.
T6 Thermostats T6 Smart Thermostats The T6 Pro Smart offers functionality that’s easy to use and smart features that are easy to love. Program it based on the homeowners’ schedule, or let it adapt to their life as plans change. Homeowners can adjust it from anywhere using a smartphone or tablet, ensuring maximum comfort when at home and energy savings whether they are home or away. • Optional ventilation control for projects that need to meet the ASHRAE 62.
T6 Thermostats T6 Hydronic Thermostats T6 Pro Hydronic Programmable Thermostat can be used to control the ambient air temperature or floor temperature or both. You can choose among the following temperature control modes: A mode: Controls and displays the ambient air temperature only. F mode: Controls and displays the floor temperature only using an external floor temperature sensor.
Programmable Thermostats Prestige® 2-Wire IAQ Thermostat • Customizable Service Reminders allow dealers to remind their customers when it’s time to call for service, when their warranty is expiring and to provide customized alerts. • USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats. • USB port for adding the dealer’s full color business logo on the screen.
Programmable Thermostats VisionPRO® 8000 with RedLINK® technology VisionPRO® 8000 with RedLINK® technology is a touchscreen thermostat, 7 day programmable and selectable for residential or light commercial use. Controls up to 3-stages of heat and 2-stages of cool in a heat pump system and up to 2-stages of heat and 2-stages of cool in a conventional system. • Thermostat works standalone or with the THM5421R1021 Equipment Interface Module or with the TrueZONE Wireless Adapter.
RedLINK® Accessories THM5421 Prestige® 2-Wire IAQ Comfort System Equipment Interface Module THM5421 Equipment Interface Module for Prestige® IAQ and VisionPRO® 8000 with RedLINK®. Equipment Interface Module controls up to 4-stages of heat and 2-stages of cool in a heat pump system and up to 3-stages of heat and 2-stages of cool in a conventional system. Three sets of Universal IAQ contacts to control humidification, dehumidification, and ventilation.
RedLINK® Accessories RedLINK Internet Gateway The RedLINK® Internet Gateway provides remote access to Prestige, RedLINK 8000, or RedLINK FocusPRO thermostats through the internet, smartphone or tablet. • RedLINK enabled to communicate with compatible wireless devices. • Control any Prestige, RedLINK 8000, or RedLINK FocusPRO thermostat. • 3 foot ethernet cable included. • Simple installation to home or business router.
RedLINK® Accessories C7189 Wireless Indoor Air Sensor The Remote Indoor Sensor works with select RedLINK® enabled thermostats. • Used to sense temperature if the thermostat is installed in a poor temperature sensing location. • Small remote temperature sensor to match any room decor. • Easy to install and use. • Factory calibrated; no field calibration required.
RedLINK® Accessories REM5000 Portable Comfort Control Applications: Zoned and Non-Zoned Applications Changeover: Auto or Manual Differential Temperature: ± 1°F (±0.5°C) Operating Temperature Range: 32°F to 120°F (0°C to 48.9°C) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Power Method: Battery Use the Portable Comfort Control anywhere in the home to experience a new level of comfort and convenience. Works in both zoned and non-zoned applications.
Electric Heat Thermostats LineVoltPRO® 8000 7-Day Programmable Hydronic Thermostat The TL8100 Hydronic Thermostat offers the energy savings of a programmable control for a wide variety of applications without a need to carry multiple thermostats for different applications. Controls 2-way and 3-way zone valves or circulator pumps.
Hydronic Zoning System Hydronic Pro Zoning System Zoning is an ideal way to help your customers maximize comfort while enjoying energy savings, but zoning for homes with a central boiler has been time consuming—until now. Hydronic Zoning Panels feature simplified setup and wiring for quick installation. You’ll be able to offer your hydronic customers the many benefits of zoning easier than ever before. • Familiar Setup – If you know how to install an existing panel, you can install ours too.
Hydronic Zoning System THERMOSTATS R WC R WC THERMOSTATS R WC 1 R WC 1 RWC 1 R W C Zone 2 Zone 1 T-stat Call HPZC104 Four Zone Zone Valve Controller T T End Switch T T Boiler R W C R W C Zone 3 Zone 4 24 VAC Thermostats 3 2 On/Off On/Off 4 R W C Zone 2 R W C Zone 3 BOILER TT R W C R W C Zone 5 Zone 4 24 VAC Thermostats 2 T T End Switch 3 4 On/Off 5 Priority Zone 1 1 2 3 4 N H 24 VAC Zone Valves Zone 2 Zone 3 Zone 4 12 3 4 12 3 4 12 3 4 On On/Off HPZC105 Power Boiler DHW Pr
Hydronic Zoning System THERMOSTAT R WC COMMON NOT REQUIRED ON SOME THERMOSTAT MODELS. 24 VA Transformer R WC HPSR101 Switching Relay Power T-stat Call Input 120vac Relay One Relay Two Com NO NC N H Com NO NC V4043 SERIES VALVE OR EQUIVALENT BLOWER 120 VAC FROM DISCONNECT NOTES: GROUND REQUIRED BUT NOT SHOWN FOR DRAWING CLARITY. VERIFY WIRING CONFORMS TO LOCAL CODE. INSTALLER MUST VERIFY THE FOLLOWING: 1. BLOWER MOTOR IS POWERED BY 120 VOLTS 2.
Hydronic Zoning System THX9421R5021 THERMOSTAT THX9421R5021 THERMOSTAT R C R C R C W W2 W3 Y Y2 G L W W2 W3 Y Y2 G L U3 U3 U2 U2 U1 U1 U3 U3 U2 U2 U1 U1 RC RH R C RC RH R C S2 S2 S1 S1 S2 S2 S1 S1 1 R C 2 THM5421R1021 EIM 1 2 R WC R WC R WC Zone 1 Zone 2 Zone 3 Priority 24 VAC THERMOSTATS 3 1 A SEPARATE THX9421R5021 THERMOSTAT AND THM5421R1021 EIM ARE NEEDED. THE THERMOSTAT AND EIM ARE SOLD TOGETHER IN THE YTHX9421R5085 KIT.
Hydronic Zoning System THM5320R EIM TH6320R WIRELESS 1 PROGRAMMABLE FOCUSPRO 1 C R Rc Rh THM5320R EIM W W2 Y Y2 G L POWER HEAT COOL FAN 1 TH5320R WIRELESS 1 NON PROGRAMMABLE FOCUSPRO A B C D W W2 Y Y2 G L POWER HEAT COOL FAN RAS RAS 1 C R Rc Rh RAS RAS A B C D 2 2 2 1 THE TH6320R WIRELESS PROGRAMMABLE THERMOSTAT AND EIM ARE SOLD TOGETHER IN THE YTH6320R1001 KIT. THE TH5320R WIRELESS NON- PROGRAMMABLE THERMOSTAT AND EIM ARE SOLD TOGETHER IN THE YTH5320R1000 KIT.
Hydronic Zoning System Zone Valve Controller Priority Zone 1 1 2 3 4 Zone 2 1 2 3 4 24 VAC Zone Valves Zone 3 Zone 4 1 2 3 4 1 23 4 Pump End Zone 1 Pump Switch End Switch X N/O COM N/C X Input 120VAC N H 1 2 3 C W/Y End Switch TACO 570 SERIES VALVE TACO EBV VALVE MCR37974 Taco Zone valves with HPZC Hydronic Panels. NOTE: This diagram is specific to how Taco valves can wire to an HPZC zone valve panel. All zones other than an optional Domestic Hot Water zone are wired the same.
Hydronic Zoning System THERMOSTAT OR EIM U1 U1 6 4 R RC C W Y G 5 3 1 C W Y G R FURNACE R WC R WC R WC Zone 1 Zone 2 Zone 3 Priority 24 VAC THERMOSTATS 2 1 COMMON WIRE IS OPTIONAL ON MOST NON-WI-FI MODELS. IF COOLING IS NOT USED, DISREGARD THE Y AND G WIRES. 2 THIS DIAGRAM SHOWS HOW THE THERMOSTAT OPTIONS LISTED BELOW CAN BE INTEGRATED TO A HYDRONIC PANEL FOR STAGE 1 HEAT AND A DIFFERENT HEAT SOURCE FOR BACKUP HEAT.
Hydronic Zoning System AQ250 Electronic Relay Boiler Control Panel for Hydronic Zoning System AQ250 boiler controls for single temperature, residential hydronic heating systems ensure ample supply of hot water for space heating and domestic uses. Convert single zone heating systems or upgrade relay-logic zoning systems.
Hydronic Zoning System AQ255 and AQ257 Zoning Expansion Panel for Hydronic Zoning System AQ255 expansion zoning panels work with AQ2000 boiler control panels and AQ1000 communicating thermostats to control up to four space heating zones, up to 16 zones with additional panels.
Hydronic Zoning System AQ25042B AQ25542B From R on AQ10X38 Transformer To boiler TT To R on AQ15540B (2) To C on AQ15540B (2) -- SENSORS-Boiler Supply Return From C on AQ10X38 Transformer To B B Exp. Bus IN Connection on AQ15540B (2) To Domestic Hot Water Aquastat From B B Exp. Bus OUT Connection on AQ15540B (1) THERMOSTATS THERMOSTATS Zone 5 Zone 6 Zone 7 Zone 8 R C Primary Return POWER IN AQ10X38 Electrical Connections POWER INPUT HEAT SENSORS T DHW T B B BOILER EXP.
Hydronic Zoning System AQ1000TN2 Non-Programmable Communicating Thermostat The AQ1000TN2 thermostat controls the ambient air or floor temperature in hydronic heating applications. To provide zoning control, it communicates with and is powered by a AQ2000 series zoning module.
Hydronic Zoning System AQ2000 Series Replacement Zoning Modules Replacement Zoning Modules for AQ2000 panels Thermostat Compatibility: AQ1000 Series 2-wire communicating thermostats and most digital thermostats R-C Input (on Control and Zoning Modules): 24 Vac Class II (input on Control and Zoning Modules) B-B Communication Bus Terminals: Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
Hydronic Switching Relays R847 Heavy Duty Relay R847A wired to break one side of the circuit with SPST switching. R847A T T THERMOSTAT Designed for control of relatively heavy duty 120 or 240 Vac electrical loads such as cooling compressors. • Internal, flexible leads permit SPST or DPST switching. MOVE FLEXIBLE LEAD TO L1 Application: Enclosed heavy duty DPST or SPST switching relay for 24 volt 2-wire thermostat control of high-current loads such as cooling compressors.
Hydronic Switching Relays RA89; RA832; R845 Hydronic Switching Relay Provides intermediate switching of a line voltage device from a low voltage controller. • Integral transformer provides low voltage power for control circuit Input Voltage: 120V Electrical Connections: Control Circuit- 2-Wire Frequency: 50 Hz; 60 Hz Coil Ratings Voltage: 24 Vac Coil Ratings Current: 0.4A Electrical Ratings: Maximum Input-5.0 W Contact Ratings (resistive): At 120 Vac –10A; 240 Vac – 6.
Hydronic Switching Relays R8845U Universal Switching Relay Dimensions in inches (millimeters) 4-7/16 (118) 1-3/8 (35) 2-1/8 (54) 7/8(22) DIAMETER KEYHOLE TYPE MOUNTING HOLE 3/16 (5) DIAMETER 3/8 (10) DIAMETER 5-3/8 (137) 6-1/4 (159) 7/32 (6) DIAMETER MOUNTING HOLE The R8845U Universal Switching Relay with 24 V transformer provides intermediate switching of line- and low-voltage devices from a lineor low-voltage controller and is typically applied in Hydronic heating systems.
Hydronic Switching Relays RA889A Switching Relay The RA889A Switching Relay with 24 V controller provides intermediate switching of line- and low-voltage devices from a lineor low-voltage controller and is typically applied in Hydronic heating systems. • High load switching capability. • Troubleshooting LED. • Push-to-test button. • Replaceable transformer fuse. • Long-life DC relay drive control technology.
Temperature Controllers T775 Series 2000 Stand-Alone Controllers The T775 electronic remote temperature controllers are the next generation of commercial and agricultural controls capable of remote sensing of temperature and providing switched and/or proportional outputs to various types of loads. • Save time on installations with the easy-to-use graphical Interface, large display, and the intuitive programming.
Temperature Controllers Dimensions in inches (millimeters) TOP 1 (25.5) 7/8 (22.5) 2 15/16 (74) 4 13/32 (112.1) 3 31/32 (101) LEFT 1/2 (12.4) RIGHT 4 1/16 (103.4) 1/64 (3.8) 8 5/32 (207.1) 7 23/32 (196) 4 1/16 (103.4) 2 13/16 (71.8) 2 11/16 (68.1) FRONT VIEW 7/8 (22.5) 7/8 (22.5) 7/8 (22.5) 1 (25.
Temperature Controllers T775 Series 2000 Special Stand-Alone Controllers T775 electronic remote temperature controller, is the next generation in commercial/agricultural control - capable of remote sensing temperature, humidity, pressure, etc., and providing switched and/or proportional outputs to various types of loads. • Universal model (T775U) can control pressure, humidity, or any variable analog input. • Special boiler model (T775P) for boiler control.
Temperature Controllers Dimensions in inches (millimeters) TOP 1 (25.5) 7/8 (22.5) 2 15/16 (74) 4 13/32 (112.1) 3 31/32 (101) LEFT 1/2 (12.4) RIGHT 4 1/16 (103.4) 1/64 (3.8) 8 5/32 (207.1) 7 23/32 (196) 4 1/16 (103.4) 2 13/16 (71.8) 2 11/16 (68.1) FRONT VIEW 7/8 (22.5) 7/8 (22.5) 7/8 (22.5) 1 (25.
Aquastat® Controllers L4006; L6006 Aquastat® Controller Approvals, CSA: File No. 095329 1 (25) KNOCKOUT FOR 3/4 (19 ) CONDUIT ON ALL MODELS. SIMILAR KNOCKOUT ON BOTTOM FOR HORIZONTAL INSERTION AND REMOTE BULB MODELS. 5/16 (8) 3/16 (5) 2 (51) 2-1/8 (54) 5-5/8 (136) Aquastat® Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required.
Aquastat® Controllers Material Number Application Switching Action Operating Temperature Range Differential Temperature L4006B1155/U Circulator SPST, contacts make on temperature rise. 100°F to 240°F (38°C to 116°C) L4006B1163/U Circulator SPST, contacts make on temperature rise. 100°F to 240°F (38°C to 116°C) L4006E1067/U High Limit; Manual Reset SPST, contacts break 130°F to 270°F on temperature rise. (54°C to 132°C) – 5°F to 30°F adj. (3°C to 17°C adj.) – 5°F to 30°F adj. (3°C to 17°C adj.
Aquastat® Controllers L4008; L6008 Remote Bulb Controller For limiting or regulating temperature of liquids in boilers or tanks. Can also sense duct or outside air temperature. • Remote temperature sensing element detects and responds rapidly to temperature changes. • Totally enclosed Micro Switch™ snap-acting switch. • Visible control point scale and external adjustment screw permit easy setting.
Aquastat® Controllers L4103 Combination Aquastat® and High Limit Controller An immersion-type control the Aquastat® Controller senses water temperature, cycles the burner through the oil primary, or provides water temperature regulation for gas systems. The controller breaks the circuit on a temperature rise past setpoint. • L4103A,B,C have a sensing element and a high limit sensor with automatic reset. • Mounts on a horizontal immersion well in water heater wall. • Adjustable temperature setting scale.
Aquastat® Controllers L8100 Aquastat® Controller L8100 are immersion type controllers for regulating and limiting the tank temperature in water heater and hydronic systems. As the water temperature rises past the setpoint, the controller switches off the gas valve. • Regulates temperature and provides energy cutoff (ECO) action on a temperature rise past the setpoint. • Includes a second sensing element that senses average water temperature to minimize stacking.
Aquastat® Controllers L4081; L6081 Multiple Aquastat® Controllers High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems. • An immersion type liquid-filled sensing element actuates two snap switches. • One switch operates as a high limit control. • The other switch operates as a low limit and/or circulator control, depending on the model. • Controller may be mounted in any positioning and needs no leveling.
Aquastat® Controllers JUNCTION BOX R4184D PROTECTORELAY™ CONTROL SS BLACK 1K2 ORANGE 1K CAD CELL F SOLID STATE SWITCH BURNER MOTOR OIL VALVE 1K1 SAFETY SWITCH HEATER IGNITION WHITE F L1 (HOT) 1 L2 CIRCULATOR 24V THERMOSTAT 2 4 3 B 1 2 B W 1R1 R L6081A T 1R T 1 RA89A SWITCHING RELAY R JUMPER ADDED POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 B TERMINALS ARE TAB TERMINALS.
Aquastat® Controllers L7224U Oil Electronic Aquastat Controller Universally compatible and easy to install the L7224U allows for quick diagnostics updates through an easy-to-read LED display enhanced with a system of flashing lights. It’s like an express checkout service for every installation. For quality circulator, oil burner and boiler control for today’s systems and tomorrow’s, the L7224U Aquastat is a state-of-the-art solution.
Aquastat® Controllers L8124 Triple Aquastat® Relay Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service. • Provide multizone control by using a separate circulator and R845 Relay for each zone. • Include diaphragm powerhead and Micro Switch™ assembly that respond to temperature changes in boiler water. • Mount directly to boiler.
Aquastat® Controllers Dimensions in inches (millimeters) 3-1/8 (79) 2-1/8 (54) (VERTICAL MOUNT) 3-3/8 (86) LOW VOLTAGE THERMOSTAT L8124A,C 2 3-1/16 (78) (HORIZONTAL MOUNT) G T T 6-1/8 (156) 1 L1 (HOT) 2 L2 1K R W 1-1/4 (32) (VERTICAL MOUNT) 1/8 (3) B 1K1 LOW LIMIT/ CIRCULATOR ZR 1-1/4 (32) (HORIZONTAL MOUNTÑBOTTOM) ZC KNOCKOUTS FOR 1/2 (13) CONDUIT HIGH LIMIT 1K2 3 R B1 4-5/16 (110) B2 M8925 TH C1 ZONE 2 THERMOSTAT V8043F TH TR C2 LINE VOLTAGE CIRCULATOR V8043F TH TR
Aquastat® Controllers L8148 Aquastat Relay Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. • High limit opens burner circuit only. • Select models include transformer and accessory terminals for adding a remote low limit controller. • Case available for horizontal or vertical mounting. • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
Aquastat® Controllers Dimensions in inches (millimeters) 3-1/8 (79) 24V THERMOSTAT 2-1/8 (54) (VERTICAL MOUNT) 3-3/8 (86) W R 3-1/16 (78) (HORIZONTAL MOUNT) TV L6006 B LOW LIMIT CONTROLLER 6-1/8 (156) PP 1-1/4 (32) (VERTICAL MOUNT) 1/8 (3) T Z 2 TP 3 B MILLIVOLTAGE POWERPILE® GAS VALVE PP W HIGH LIMIT R C1 C2 TH2 B1 B2 TH1 B3 G 1 CIRCULATOR TH TR LOW VOLTAGE GAS VALVE (eg, VR8300) G L2 L1 5 1-1/4 (32) (HORIZONTAL MOUNTÑBOTTOM) L8148J 4 L1 L2 (HOT) THTR L8148J L1 KNOC
Aquastat® Controllers 24 VAC THERMOSTAT D892/M892 4 197516A CABLE L8148E1265 4 4 3 2 TV Z 3 FUSE R 1K2 3 1 62 B 2 5 1 1 6-PRONG FEMALE MOLEX B1 RECEPTABLE IN L8148E AND 5-PRONG MALE 5 MOLEX PLUG ON CABLE REMOVE PLUG-IN THAT JUMPERS PINS 2 AND 3 WHEN USING VENT DAMPER. 3 AFTER VENT DAMPER IS PLUGGED INTO L8148E1265, FUSE BLOWS WHEN THERMOSTAT FIRST CLOSES. AFTER FUSE BLOWS, L8148E1265 OPERATES ONLY WHEN VENT DAMPER IS CONNECTED.
Aquastat® Controllers Outdoor Reset and Domestic Hot Water Priority Outdoor reset saves energy by optimizing a boiler’s settings based on the actual outdoor temperature. We offer wired and wireless AquaReset® Outdoor Reset solutions. While both versions offer the same incredible energy savings, the Wireless AquaReset® solution installs in only 30 minutes thanks to RedLINK® wireless communication.
Aquastat® Controllers R8182 Combination Protectorelay® and Hydronic Heating Controllers Immersion type Aquastat® controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. • Use in intermittent ignition applications. • Capable of zone control with zone valves. • Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. • Flame failure during the running cycle results in a 45 second attempt to restart.
Well Assemblies Well Assemblies Material Number Materials Capillary Diameter Insertion Shell (internal Well Spud Size Length diameter) Insulation Description Depth 121371A/U Copper 5/64 in. 3 in. 3/8 in. 1/2 in. - 14 NPT 1 1/2 in. (13 mm - 14 NPT) 121371B/U Copper 5/64 in. 3 in. 3/8 in. 3/4 in. - 14 NPT 1 1/2 in. (19 mm - 14 NPT) 121371L/U Copper 5/64 in. 3 in. 3/8 in. 1/2 in. - 14 NPT 3 in. (13 mm - 14 NPT) 121371M/U Copper 5/64 in. 3 in. 3/8 in. 3/4 in. - 14 NPT 3 in.
Motorized Zone Valves VC Series Cartridge Cage 3-way Mixing Control central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, it can be controlled by either a low voltage SPST or SPDT or floating controller such as a room thermostat, Aquastat control, or flow switch. • Three-way valves. • Minimal actuator power consumption. • Double insulated actuator. • Quick-connect or one-meter cable electrical connections available.
Motorized Zone Valves Valves Material Number VCZNB7600/U VCZNB7400/U VCZMD6100/U VCZMA6100/U VCZMA7100/U VCZNB6100/U VCZNB7100/U VCZNB6000/E VCZNB6000/U VCZMA6000/E VCZMA6000/U VCZMK6100/U VCZMK6131/U VCZML6100/U VCZML7100/U VCZML6000/E VCZML6000/U VCZMK6000/U VCZMR6100/U VCZMS6100/U VCZND6100/U VCZNE6100/U Body Pattern Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way Three-way
Motorized Zone Valves VC Series Quick Open Cartridge Cage 2-way Zone Valve Control central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, it can be controlled by either a low voltage SPST or SPDT or floating controller such as a room thermostat, Aquastat control, or flow switch. • Two-way valves. • Minimal actuator power consumption. • Double insulated actuator. • Quick-connect or one-meter cable electrical connections available.
Motorized Zone Valves VC Series Linear/Modulating Cartridge Cage 2-way Zone Valve Control central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, it can be controlled by either a low voltage SPST or SPDT or floating controller such as a room thermostat, Aquastat control, or flow switch. • Two-way valves. • Minimal actuator power consumption. • Double insulated actuator. • Quick-connect or one-meter cable electrical connections available.
Motorized Zone Valves Material Number Supply Voltage Frequency Power Stroke Timing Consumption @60 Hz End Switch/Control Internal Auxiliary Cable Length Switch Fail Safe Action VC8711ZZ11/U VC8714ZZ11/U VC7931ZZ11/U 24 Vac 24 Vac 24 Vac 60 Hz 60 Hz 50 Hz; 60 Hz 6 VA 6 VA 6 VA 6 seconds 6 seconds 120 seconds 2-Position SPST 2-Position SPST 2-10 Vdc Yes Yes 39.4 inches 60 inches 39.
Motorized Zone Valves Cartridge Cage Valve Accessories Material Number Description 40007029-002/U Wrench for cartridge (included with sweat valves and all replacement cartridges) VCZZ Valve Replacement Cartridges Material Number Description VCZZ1000/U Replacement cartridge, red spring, for VC series 2-way valves, with quick open flow for use w/ 2-position or fail safe proportional actuators. Includes cartridge wrench.
Motorized Zone Valves V4043 Line Voltage Zone Valves Flare Connection Sweat Connection Two way on-off line voltage valves consist of an actuator motor and valve assembly for controlling the flow of hot or chilled water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve. • Compact construction for easy installation.
Motorized Zone Valves Dimensions in inches (millimeters) V4043, V8043 SWEAT COPPER CONNECTION MODELS 6 V4044, V8044 SWEAT COPPER CONNECTION MODELS 5 3-1/2 (89) 1 7/8 DIA.
Motorized Zone Valves V4043 Line Voltage Zone Valves for Steam Flare Connection Two way on-off line voltage valves consist of an actuator motor and valve assembly for controlling the flow of low pressure steam. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve. • Compact construction for easy installation.
Motorized Zone Valves V8043 Low Voltage Normally Closed Zone Valves Flare Connection Sweat Connection NPT Connection Sweat Connection with terminal block Two-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.
Motorized Zone Valves Material Number Capacity Capacity Pipe Size Pipe Size Connection Maximum Differential (Cv) (Kv) (inch) (DN) Type Pressure Ratings (Close-off) (psi) Maximum Differential Pressure Ratings (Close-off) (kPa) End Switch Rating Electrical Connections Auxiliary End Switch 50 VA pilot duty @ 24 V; 4.4 A running with 26.4 A inrush @ 120 V 50 VA pilot duty @ 24 V; 4.4 A running with 26.4 A inrush @ 120 V 50 VA pilot duty @ 24 V; 4.4 A running with 26.
Motorized Zone Valves V8043 Zone Valves with Press Connection (US and Canadian Compliant) 2–11/32 (59) 1 2–11/32 (59) 3–7/16 (88) 5–1/4 (133) END SWITCH 3–3/32 (79) TH TR 7/8 (23) TH TR 4–1/16 (103) 3–7/16 (88) 5–1/4 (133) 3–3/32 (79) 7/8 (23) X M37333 X Dimensions (V8043A, V8043E). Measurements in inches (mm). See Table below. 1 ALLOW ADEQUATE CLEARANCE TO ACCESS WIRING TERMINALS. M37334 Dimensions (V8043F). Measurements in inches (mm). See Table below. X dimension.
Motorized Zone Valves V8043 Low Voltage Normally Closed Zone Valves for Canada Flare Connection Sweat Connection NPT Connection Two-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve.
Motorized Zone Valves Maximum Differential Static Pressure Rating (psi [kPa]) Pressure Ratings Closeoff (psi [kPa]) Pipe Size (DN) Connection Frequency Capacity Capacity Auxiliary Type (Cv) (Kv) End Switch V8043G1018/U 3/4 in. DN20 Sweat 50 Hz; 60 Hz 3.5 Cv 3 Kv N.O. SPST 20 psi (138 kPa) V8043G1026/U 1 in. DN25 Sweat 50 Hz; 60 Hz 3.5 Cv 3 Kv N.O. SPST 20 psi (138 kPa) V8043G1034/U 3/8 in. DN10 Flare 50 Hz; 60 Hz 3.5 Cv 3 Kv N.O. SPST 20 psi (138 kPa) V8043G1109/U 3/4 in.
Motorized Zone Valves V8043 Low Voltage Normally Open Zone Valves Sweat Connection Inverted Flare Flare Connection On-off and two-way low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • All models may be installed without disassembling the valve. • Compact construction for easy installation. • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.
Motorized Zone Valves V8043 Low Voltage Series 5000 QuickFit® Zone Valves Two-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • All models may be installed without disassembling the valve. • Compact construction for easy installation. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.
Motorized Zone Valves V8043 Low Voltage Series 5000 QuickFit® Zone Valves for Canada Flare Connection Two-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • All models may be installed without disassembling the valve. • Compact construction for easy installation. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.
Motorized Zone Valves V4044 Line Voltage Diverting Valves Flare Connection Sweat Connection Application: Hydronic Control Valve Type: Zone Valve Body Pattern: Three-way, Diverting Valve Action: Spring Return to port A Voltage: 120 Vac; Power Consumption – 9.6 VA Frequency: 60 Hz Actuation: Two position De-energized Position: Port A Normally Closed Electrical Connections: 18 in.
Motorized Zone Valves V8044 Low Voltage Diverting Valves Flare Connection Sweat Connection NPT Connection On-off and diverting low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve.
Motorized Zone Valves Fan Coil Actuators VU443, Coil Actuators VU443,VU444; VU444;VU843, VU843;VU844 VU844Fan Fan Coil Actuators Humidity resistant fan coil valve actuators are used in conjunction with VU52, VU53 and VU54 valves for controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. • Compact construction for easy installation. • Fits under the cover of most baseboard convectors with actuator fitted to valve body.
Motorized Zone Valves Material Number Frequency Internal Auxiliary Switch Stroke Spring Return Timing VU443A1008/U 60 Hz 0 22 deg. VU443A1024/U 60 Hz 0 22 deg. VU443A1057/U 60 Hz 0 22 deg. VU443A1115/U 0 22 deg. VU444A1007/U 50 Hz; 60 Hz 60 Hz 0 45 deg. VU444A1098/U 60 Hz 0 45 deg. VU444A1106/U 50 Hz; 60 Hz 60 Hz 0 45 deg. 0 45 deg. VU843A1004/U 50 Hz; 60 Hz 0 22 deg.
Motorized Zone Valves Fan Coil Valves VU52; Valves VU52;VU53 VU53Two-way Two-wayFan FanCoil Coil Valves • Compact construction for easy installation. • Fits under the cover of most baseboard convectors with actuator fitted to valve body. • VU52 and VU53 provide 2-way, straight-through control of water. • Available in normally closed (VU53) or normally open (VU52) configurations. • 300 psi (2,000 kPa, PN20) operating pressure rating. • Patented ball seal provides long service life, soft close off.
Motorized Zone Valves Fan Coil Valves Three-way fan coil zone valves are used to control hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. • Compact construction for easy installation. • Fits under the cover of most baseboard convectors with actuator fitted to valve body. • VU54 provides three-way diverting control of water. • 300 psi (2,000 kPa, PN20) operating pressure rating. • Patented ball seal provides long service life, soft close off.
Motorized Zone Valves Zone Valve Replacement Parts Material Number Description 272704B/U Two 3/8 in. flare to 3/4 in. sweat adapters 272708A/U 272708B/U 272708C/U Two 1/2 in. inverted flare to 1/2 in. sweat adapters Two 1/2 in. inverted flare to 3/4 in. sweat adapters Two 1/2 in. inverted flare to 1 in.
Motorized Zone Valves Zone Valves Replacement Heads Ambient Temperature Range: 125°F Maximum (52°C Maximum) Material Number Description 40003916-001/U 240V, 50 Hz Replacement actuator for V4043 40003916-002/U 240V, 50 Hz Replacement actuator for V4044 40003916-003/U 240V, 50 Hz Replacement actuator for V4073 40003916-011/U 24V, 60 Hz Replacement actuator for V8043C 40003916-012/U 24V, 60 Hz Replacement actuator for V8043G 40003916-013/U 24V, 60 Hz Replacement actuator for V8043F 40003916-014/U 24V, 60 Hz
Motorized Zone Valves Material Number Voltage Frequency Auxiliary Switch Ratings Used With 24 Vac 40003916-548/U 24 Vac, 50/60 Hz Replacement Screw terminal block on same side head for V8043F, With End of manual lever Switch 50 Hz; 60 Hz 4.4 A running @ 120 V; 50 VA pilot duty @ 24 V Two-way valves; Valves with Action of Spring return to close 802343/U Description Electrical Connections Small O-Ring; .114 inside dia.; .
AquaPUMP Hydronic Circulating Pump AquaPUMP Fixed Speed Hydronic Circulating Pumps The PC3F in-line, wet rotor circulator with universal flange is designed for applications in closed-loop hydronic heating and cooling systems, as well as in solar systems. The pump is non-submersible and for use in dry, frost-free, well-ventilated installations.
AquaPUMP Hydronic Circulating Pump Flow Curves PC3F1558IUF00 22 PC3F2699IUF00 30 20 18 16 WITHOUT CHECK VALVE WITH CHECK VALVE 25 WITHOUT CHECK VALVE WITH CHECK VALVE 20 14 H 12 (FEET) 10 3 H 15 (FEET) 3 2 10 8 6 2 1 5 4 1 2 0 0 2 4 0 6 8 10 12 5 10 15 18 16 14 US GPM 0 20 US GPM 25 30 35 M32833A M32852A PC3F4344IUF00 18 16 WITHOUT CHECK VALVE WITH CHECK VALVE 14 12 10 H (FEET) 8 3 6 2 1 4 2 0 0 5 10 15 20 25 30 35 40 US GPM 63-8702 45 50 55 60 6
AquaPUMP Hydronic Circulating Pump AquaPUMP Variable Speed Hydronic Circulating Pumps The Resideo AquaPUMP Variable speed, in-line, wet rotor circulator is designed for variable or constant pressure applications in closed-loop hydronic heating and cooling systems, as well as open circulation systems (stainless steel model).
AquaPUMP Hydronic Circulating Pump Technical Data PCVF-ECM2020 Performance Curves: Supply Voltage: 1 x 115 V – 10%/6% Amp Watt Table 3. Supply Voltage. Minimum Maximum 0.05 0.72 5 45 Inlet Pressure: Minimum inlet pressure in relation to liquid temperature. Table 4. Inlet Pressure. Liquid Temperature Minimum Inlet Pressure 150 ºF (65 ºC) 3.0 ft (0.91 m) 167 ºF (75 ºC) 4.4 ft (1.34 m) 194 ºF (90 ºC) 9.2 ft (2.8 m) 230 ºF (110 ºC) 36.1 ft (11 m) AUTO: Circulator adapts to system demand over time.
Differential Pressure Regulators D146 Differential Pressure Regulators The differential pressure regulator eliminates excessive pump head pressure, when most radiator valves are closed due to reduced demand, by controling flow through a bypass line when the difference between supply/return exceeds the setpoint. • Install between supply and return sides of a hydronic system to stabilize pressure differential and reduce the effects of demand changes.
Air Vents and Eliminators EA79 Industrial Air Vents The EA79 Industrial Air Vent purges air from high pressure mains and equipment in hot or cold closed water systems. • Built-in shutoff valve for servicing without system shutdown. • Built-in vacuum breaker. • Removable float/valve assembly for easy servicing. • Safety drain connection and vent cap with leakage guard. • Brass shell construction.
Air Vents and Eliminators EA122A Automatic Air Vent for Non-Heating System Applications The EA122A Automatic Air Vent purges air from high pressure mains and equipment in hot or cold potable water systems. • Includes removable float/valve assembly for easy servicing. • Not for use in steam systems. • Body, cover and float assembly made of thermoplastics.
Air Vents and Eliminators EA122A Automatic Air Vent for Heating System Applications The EA122A Automatic Air Vent purges air from high pressure mains and equipment in hot or cold closed water systems. • Includes removable float/valve assembly for easy servicing. • Not for use in steam systems. • Body, cover and float assembly made of thermoplastics.
Air Vents and Eliminators GoldTop—Universal Air Vent for Residential and Commercial Heating and Cooling Systems The GoldTop offers a convenient, one-fits-all concept, to stock one vent for all your venting needs, between 1 and 150 psi systems. The revolutionary patented fulcrum design offers a venting rate of 3-4 times that of other products. • Patent No. 5,988,201.
Air Vents and Eliminators SuperVent® Air Eliminator — Eliminates Air from Hydronic Heating Systems without Bleeding The SuperVent, purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding. • No clog vent. • Dirt and Debris resistant. • 360 degree adjustable collar ring for installation flexibility. • Stainless steel concentrator which eliminates gurgling noise.
Air Vents and Eliminators SuperVent® Vent Top for Heating and Cooling Systems The SuperVent has high venting capacity and incorporates a check valve. Use with SuperVent PV Series products.
Air Vents and Eliminators SuperVent® Air Eliminator Universal Models — Eliminate Air from Hydronic Heating Systems without Bleeding The SuperVent, purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding. • No clog vent. • Dirt and Debris resistant. • 360 degree adjustable collar ring for installation flexibility. • Stainless steel concentrator which eliminates gurgling noise.
Magnetic Hydraulic Separators Magnetic Hydraulic Separators Magnetic Hydraulic Separator HYDROSEP-1XX SUBMITTAL SHEET Job Name Engineer Mechanical Contractor Contractor’s P.O. No. Representative Notes Model(s) APPLICATION OPERATING SPECIFICATIONS (UNION VERSION) Approval Service Tag No.
Magnetic Hydraulic Separators Table 5. MATERIALS Connections Max. Flow Rate GPM (m3/h) Weight lbs (kg) Volume gal (l) HYDROSEP-102-U/U 1 in. 11 (2.5) 5.95 (2.7) 0.39 (1.5) HYDROSEP-103-U/U 1-1/4 in. 17.6 (4) 8.15 (3.7) 0.66 (2.5) 1-1/2 in. 26.41(6) 12.56 (5.7) 1.18 (4.5) HYDROSEP-105-U/U 2 in. 39.62 (9) 15.87 (7.2) 1.9 (7.2) HYDROSEP-105-F/U 2 in. 46.23 (10.5) 41.88 (19) 2.64 (10) HYDROSEP-106-F/U 2-1/2 in. 77 (17.5) 55.11 (25) 4.49 (17) HYDROSEP-107-F/U 3 in.
Boiler Fill Valves NK300S-100 The NK300S Boiler Feed Combination serves as a boiler fill valve used in closed loop heating systems. The NK300S is a (re filling combination valve that contains an integrated pressure reducing valve, strainer, double check backflow preventer with air vent (to protect potable water supply against back flow of heating water into supply pipe), two shut-off ball valves, pressure gauge, and conveniently located test ports for easy inspections and check out.
Backflow Preventers “DialSet” Boiler Fill Valves Pressure regulating valve for automatic control of boiler feed water and other pressure reducing applications. Especially constructed for expansion tank mounting. • DialSet Fill Valve. • Built in check valve. Valve Type: DialSet Fill Valve Pipe Size (inch): 1/2 in. Inlet Size – 1/2 in.
Residential Expansion Tanks Sweat and Threaded Thermometers with Thermowells Thermometer with Sweat or Threaded Connection. • Brass thermowell is included to allow the thermometer to be removed without draining the system. • 2 inch or 2 1/2 inch Dial. VF06 Application: Brass thermowell is included to allow the thermometer to be removed without draining the system.
Boiler Trim Kits Boiler Trim Kit with SuperVent TK Series Combo Boiler Trim kits are a quick way to purchase boiler trim when doing a boiler change out. All kits with SuperVent include expansion tank and a high performance air eliminator. Maximum Safe Operating Pressure (psi): 100 psi Maximum Safe Operating Pressure (kPa): 689 kPA Operating Temperature Range: 240°F Maximum (115°C Maximum) Diameter: 11 in. (279 mm) Material Number Connection Size (in.) Connection Type TK30PV100FM/U SuperVent: 1 in.
Commercial Expansion Tanks TK300 Series Expansion Tanks—Heating Expansion Tanks absorb hot water expansion in closed heating systems. They are equipped with butyl diaphragms to separate the air from the system water. Pre-pressurized, the tank keeps fluids circulating and maintains minimum pressure.
Commercial Expansion Tanks Expansion Tank Sizing based on BTU’s Boiler Net Output in 1000’s of BTU/Hr MBH Finned Tube Baseboard or Radiant Panel Use Model 25 50 75 100 125 150 175 200 250 300 350 400 TK300-15 TK300-15 TK300-30 TK300-30 TK300-30 TK300-30 TK300-60 TK300-60 TK300-60 TK300-90 XPS-030V XPS-030V Type of Radiation Convectors or Unit Heaters Radiators Cast Iron Baseboard Cast Iron Use Model Use Model Use Model TK300-15 TK300-15 TK300-30 TK300-30 TK300-60 TK300-60 TK300-60 TK300-60 TK300-90
Commercial Expansion Tanks XPS Series Expansion Tanks XPS Series Expansion Tanks absorb hot water expansion in closed heating systems in larger installations. They have butyl diaphragms to separate clamped design, keep fluids circulating and maintain minimum system pressure. • For ASME construction consult factory.
Thermostatic Radiator Valves and Actuators V135 Thermostatic Mixing or Diverting Valves Application: Thermostatic mixing/diverting valve for use in hydronic heating systems. Controls loop temperature in radiant heating systems. Capacity: Standard Temperature Range: 248°F Maximum (120°C Maximum) Collar Diameter: 1 3/16 in.
Thermostatic Radiator Valves and Actuators V110 High Capacity Thermostatic Radiator Valves V110D High Capacity Thermostatic Radiator Valves with T104 Actuators provide control of temperature by modulating the flow of hot water or steam through free-standing radiators, convectors and other heating units with high capacity requirements. • Designed with the higher capacity normally required by North American heating systems.
Thermostatic Radiator Valves and Actuators Dimensions in inches (millimeters) Typical Installation V110F (Horizontal Angle Body) B 1 C MAX A B IN. (MM) M3190 C MAX IN. (MM) PIPE SIZE A IN. (MM) 1/2 INCH 2-1/4 (57) 1 (25) 5-1/8 (130) 3/4 INCH 2-9/16 (65) 1-1/8 (29) 5-1/4 (133) 1 INCH 2-15/16 (74) 1-3/16 (30) 5-1/4 (133) 1-1/4 INCH 3-1/2 (89) 2-3/16 (56) 5-1/4 (133) 1 1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED.
Thermostatic Radiator Valves and Actuators T104 High Capacity Thermostatic Radiator Valve Actuators T104A T104B T104C Provide precise and automatic control of room temperature in twopipe systems by modulating the flow of hot water or steam through free-standing radiators, convectors and other heating units with high capacity requirements. • Continually monitor and adjust room temperature for consistent comfort and relief from under-heating and overheating.
Thermostatic Radiator Valves and Actuators Dimensions in inches (millimeters) 3 5/16 (84) MAX. TOP 2-1/8 (54) 2 1/8 (54) 2 1/8 (54) 1 (25) 3 5/16 (84) MAX. M9708C 2 (50) CAPILLARY TUBE LENGTH 6 FT. 6 IN. (2 m) OR 16 FT. (5 m) 2-1/8 (54) M9731 1-13/16 (46) 2-5/32 (55) T104V 4 2-31/32 (75) M3208A CAPILLARY TUBE LENGTH 4 FT. 6 IN. (1.37 m) 2 (51) 2-1/8 (54) 1-13/16 (46) 2-5/32 (55) 2-31/32 (75) CAPILLARY TUBE LENGTH 4 FT. 6 IN. (1.
Thermostatic Radiator Valves and Actuators V200; V2000 Series Standard Capacity Thermostatic Radiator Valves Body V200LD V2040D V2040A, V2040E (Straight body) Material Number Application One-Pipe Steam Thermostatic Radiator Valves - Allow automatic temperature control in one-pipe steam or hot water systems for free standing radiators, convectors and other heating units with standard capacity requirements.
Thermostatic Radiator Valves and Actuators Dimensions in inches (millimeters) V200LD (Straight Body) V2040D (Straight Body) B MAX. 1 B MAX. A A PIPE SIZE A IN. (MM) 1/2 INCH 2-5/8 (66) 4-1/16 (104) 3/4 INCH 2-15/16 (74) 4-1/16 (104) 1 B MAX IN. (MM) 1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED. PIPE SIZE A IN. (MM) 1/2 INCH 3-3/4 (95) 4-1/6 (104) 3/4 INCH 4-3/16 (106) 4-1/6 (104) 1 INCH 4-1/2 (114) 4-1/2 (114) 1 B MAX IN.
Thermostatic Radiator Valves and Actuators HR90 TheraPro Electronic Radiator Controller The TheraPro HR90 is an electronic radiator controller with a modern design and provides features for convenience and energy saving. It is used as stand-alone controller for radiator heating control applications. For optimized readability of the backlight display the display position can be adjusted as well. The display is switched on as soon as a button is pressed or the wheel is rotated.
Thermostatic Radiator Valves and Actuators T100 Standard Capacity Thermostatic Radiator Actuators T100B Allow automatic temperature control in two-pipe steam or hot water systems for free standing radiators, convectors, and other heating units with standard capacity requirements. Provide comfort and energy savings at affordable prices. • Continually monitor and adjust room temperature for consistent comfort and relief from under-heating and overheating.
Thermostatic Radiator Valves and Actuators Dimensions in inches (millimeters) T100B CAPILLARY TUBE LENGTH 6-1/2 FT (2m) OR 16 FT. (5m) T100F 2 (50) CAPILLARY TUBE LENGTH 6-1/2 FT (2 m) 2-1/8 (54) 3-5/16 (84) MAX. 1-13/16 (46) 2-5/32 (55) 2-1/8 (54) 2-31/32 (75) M12928 M12926 T1002W T100C TOP CAPILLARY TUBE LENGTH 4-1/2 FT (1.4 m) 2-1/8 (54) 2 (50) 1-13/16 (46) 2-5/32 (55) 2-31/32 (75) CAPILLARY TUBE LENGTH 4-1/2 FT (1.
Thermostatic Radiator Valves and Actuators V2042H; V2043H One-pipe Steam Thermostatic Radiator Valve One-Pipe Steam Thermostatic Radiator Valves - Allow automatic temperature control in one-pipe steam or hot water systems for free standing radiators, convectors and other heating units with standard capacity requirements. • Continually monitors and adjusts room temperature for consistent comfort and relief from under-heating and overheating.
Thermostatic Radiator Valves and Actuators Dimensions in inches (millimeters) Typical Installation 5 4 V2042H (Body)/V2043H (Body with Vent) A 0 B MAX. 5 C 2 M3236 6 0 PIPE SIZE 3/8 INCH A IN. (MM) 1-11/16 (43) 1 B MAX IN. (MM) 2 C IN. (MM) 1-3/16 (31) 3-13/16 (97) 1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED. 2 C DIMENSION IS WITHOUT THE STEAM/AIR VENT INSTALLED.
PRODUCTS BUSINESSES WARRANTY POLICY Resideo warrants the products in this catalog (except those parts designated on Resideo's price lists as not covered by this warranty) to be free from defects due to workmanship or materials, under normal use and service, for the following warranty periods.
Our Product Brands Resideo | Honeywell Home | Resideo Braukmann For more information resideo.com/pro/water UP ® C US LISTED C ® ® PRODUCT IDENTITY Resideo Technologies, Inc. For more information For Formore moreinformation information For more information 1985 Douglas Drive North Resideo.com Resideo.com Resideo.comResideo.com Golden Valley, MN 55422 ResideoTechnologies, Technologies, Inc. Resideo Technologies, Inc. Inc. 1-800-468-1502 Resideo Technologies, Inc.