UV100E Ultraviolet System OWNER’S GUIDE INSTALLATION INSTRUCTIONS 69-1573-07
UV100E ULTRAVIOLET SYSTEM IMPORTANT Please read these instructions and keep them in your records. HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE TREATMENT SYSTEM WORKS Your UV System uses patented SmartLamp™ control technology that monitors the HVAC system to operate the lamp only when needed. This technology extends bulb life up to five times and reduces power consumption, lowering operating costs.
UV100E ULTRAVIOLET SYSTEM Surface Treatment System When installed next to the cooling coil of your system, your Ultraviolet Surface Treatment System prevents a high percentage of the growth of micro-organisms such as mold that may grow on duct surfaces, coils, and drain pans. Individual results depend on careful installation and maintenance. See Fig. 2. Your Ultraviolet Surface Treatment System operates a steady three-hours-on/ three-hours-off cycle.
UV100E ULTRAVIOLET SYSTEM BE SURE TO READ WARNINGS AND CAUTIONS BEFORE USING YOUR UV SYSTEM WARNING UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at bulbs while illuminated. View illumination only through light indicator located on lamp handle. To prevent exposure to ultraviolet light, disconnect power to Ultraviolet System before servicing any part of heating and air conditioning system.
UV100E ULTRAVIOLET SYSTEM HOW YOU CAN CHECK YOUR ULTRAVIOLET SYSTEM Your UV System is designed to prevent accidental contact with electrical voltage and with ultraviolet rays in the sealed unit⎯the ultraviolet lamp does not illuminate unless the base is mounted on your forced air system duct. It is recommended that every month you verify that your ultraviolet lamp is operating. View the bulb only through the lamp light indicator on the lamp handle. See Fig. 3.
UV100E ULTRAVIOLET SYSTEM UV BULB CLEANING REMINDER SCHEDULE , (year) INSTALLATION DATE: (month) YEAR J F M A M J J A S O N D M13516A Fig. 4. UV bulb cleaning reminder schedule. To clean your bulbs: 1. Disconnect the power to your heating and cooling system. 2. Unplug or turn off power to your UV System and allow the bulb to cool for at least 15 minutes. 3. Rotate your lamp handle counterclockwise and gently pull the lamp handle to remove the bulb. See Fig. 5. M22842 Fig. 5.
UV100E ULTRAVIOLET SYSTEM 4. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with glass cleaner. If you touch the lamp glass with your hands, be sure to clean the area of any oils left from bare hands. See Fig. 6. M22844 Fig. 6. Clean glass with soft cloth. 5. Also wipe away any dust that may have collected between the lamp light indicator base and the black bulb base. See Fig. 7. LAMP LIGHT INDICATOR BASE M22846 Fig. 7. Wipe lamp light indicator base. 6.
UV100E ULTRAVIOLET SYSTEM 7. Insert the bulb into the base with the lamp light indicator at the eleven o’clock position. Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base. See Fig. 8. M22848 Fig. 8. Position bulb for insertion back into the lamp base. 8. Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 9. M22850 Fig. 9. Snap bulb into place. 9. 10.
UV100E ULTRAVIOLET SYSTEM NOTE: Failure to wait ten minutes for the airflow sensor to calibrate before powering the system fan causes the airflow sensor to incorrectly calibrate and the device to incorrectly function. If this occurs, remove power to the furnace or turn off the system fan, wait ten minutes, and then resume normal fan operation. 11. 12. Verify that your ultraviolet bulb is operating by viewing only through the lamp light indicator on the lamp handle.
UV100E ULTRAVIOLET SYSTEM 8. 9. 10. Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 9. Reconnect power to your UV System. For UV Air Treatment Systems, wait ten minutes for the airflow sensor to calibrate. During this time, the furnace fan must remain off.
UV100E ULTRAVIOLET SYSTEM 11 69-1573—07
UV100E ULTRAVIOLET SYSTEM Resideo Technologies, Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 www.resideo.com 69-1573—07 M.S. Rev. 04-21 | Printed in United States © 2021 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.