Install Instructions

UV100E ULTRAVIOLET SYSTEMS
68-0262—09 10
9. Reconnect power to your UV System.
10. For Air Treatment Systems, wait ten minutes for the
airflow sensor to calibrate. During this time, the fur-
nace fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor
to calibrate before powering the system fan
causes the airflow sensor to incorrectly calibrate
and the device to incorrectly function. If this
occurs, remove power to the furnace or turn off
the system fan, wait ten
minutes, and then resume normal fan operation.
11. Verify that ultraviolet lamp is operating by viewing
only through the lamp light indicator on the lamp
handle. Never look directly at your bulbs while illumi-
nated.
12. Reconnect power to your heating and cooling sys-
tem.
CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing
ultraviolet bulb(s).
Bulb Replacement
Replacement of the bulb in your ultraviolet lamp when the
LED is solidly lighted is required to maintain effectiveness.
1. Obtain the correct replacement bulb for your unit.
See Table 1.
2. Disconnect power to your heating and cooling sys-
tem.
3. Unplug or turn off power to your UV System and
allow the lamp to cool for at least 15 minutes.
4. Rotate the lamp handle counterclockwise and gently
pull the lamp handle to remove the bulb(s). See
Fig. 11.
5. If you have a SnapLamp™ handle, follow steps 5 and
6; otherwise, proceed to step 7. Grasp the
SnapLamp™ handle in one hand and the lamp glass
in the other and pull straight apart. See Fig. 16.
Fig. 16. Disconnect lamp glass from SnapLamp™
handle.
6. Insert the new lamp glass into the SnapLamp™ han-
dle by aligning the notch and pushing straight
together. See Fig. 17.
Fig. 17. Replace lamp glass in SnapLamp™ handle.
7. Insert the lamp handle into the base with the lamp
light indicator at the eleven o’clock position. Con-
tinue pushing and gently rotating counterclockwise
until the lamp handle inserts fully into the base. See
Fig. 4.
8. Rotate the lamp clockwise until it snaps into place
with the lamp light indicator aligned with the raised
button on the unit cover. See Fig. 6.
9. Reconnect power to your UV System.
10. For UV Air Treatment Systems, wait ten minutes for
the airflow sensor to calibrate. During this time, the
furnace fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor
to calibrate before powering the system fan
causes the airflow sensor to incorrectly calibrate
and the device to incorrectly function. If this
occurs, remove power to the furnace or turn off
the system fan, wait ten minutes, and then
resume normal fan operation.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at bulbs while illuminated.
View illumination only through lamp light indicator
located on lamp handle.
To prevent exposure to ultraviolet light, disconnect
power to ultraviolet system before servicing any
part of heating and air conditioning system.
11. Verify that your ultraviolet lamp is operating by view-
ing only through the lamp light indicator on the
lamp handle. Never look directly at your bulb while it
is illuminated.
12. Reconnect power to your heating and cooling sys-
tem.
13. Press and hold the reset button for five seconds to
reset the internal timers.
Table 1. Select a Replacement Bulb/Handle Assembly
or Replacement Bulb.
Unit Description
Replacement
Bulb/Handle
Assembly
SnapLamp™
Replacement
Bulb
UV100E1043
Air Treatment System
UC100E1006 UC18W1004
UV100E2009
Air Treatment System
UC100E1030
(two required)
UC36W1006
(two required)
UV100E3007
Surface Treatment
System
UC100E1030 UC36W1006
M22851
M22853