Ideal when…
• TrueDRYDR65willnotbeductedtoa
forced air HVAC system.
Attach3/4-in.maleNPTdrainnozzle.
Connect 1/2-in. drain tube to male connection drain outlet.
Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved drain
or condensate pump.
Plumbing
Install to Fit Your Application (continued)
TrueDRY
M33152
SEPARATE
RETURN
SUPPLY
TrueDry DR65 Dehumidication System 69-2089EFS—12
6
D
Dedicated Return to Main Return
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27325
Main Return to Main Return
Ideal when…
• RunningTrueDRYDR65withA/C
operation.
• Minimizingdischargeairtemperature
(DAT) increase is preferred.
• Accesstoadedicatedcentralreturnfor
TrueDRY DR65 is not available.
Note: Running TrueDRY DR65 after A/C
shutoff may cause excess water on A/C
evaporator coil to rehumidify air when
not running A/C.