Install Instructions

Specifications
Install DR65A3000 according to National Electric Codes.
Dimensions in inches and (mm):
Product weight: 60lb (27 Kg)
Shipping weight: 68lb (31 Kg)
Shipping dimensions: 16.7” H × 17” W × 32.9” L
Media Filter: MERV 11, 9” H x 11” W x 0.75” D
Drain connection: 3/4” threaded female NPT
connection.
Duct connections: 8” round inlet and outlet. ABS
plastic, compatible for connection to rigid or
flexible ducting with sheet metal screws and/or
tape.
Cabinet: 20 gauge galvanized steel powder-coat
painted.
Insulation: R value 1
Compressor: Rotary-style, 6.1 KBTU
Refrigerant: R410A, 15 oz.
Operating Temp Range (outside cabinet):
34ºF to 135ºF (1.1ºC to 57.2ºC)
Operating Humidity Range: 099% RH
Input ratings
Electrical input voltage: 120 VAC, 60 Hz
nominal
Input current: 5.2 A
Output ratings
Power transformer to R/C terminals:
24 VAC, 0.85 A
Energy Performance: 2.22 liters (4.7 pints)
per kilowatt hour (KWH)
Standards and approval body
requirements
ETL Listed per UL 474 and
CSA C22.2 No 92
ENERGY STAR rated.
DryBulb Temp Intake Humidity Capacity (Pints/Day)
80°F (26.7°C) 60% RH 65
70°F (21.1°C) 60% RH 47
60°F (15.6°C) 60% RH 34
Home Size
(square ft) @
8 ft ceiling
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor
(pints/day)
50% RH Indoor
(pints/day)
40% RH Indoor
(pints/day)
2080 4954 5558 7178
2600 6168 6572 9097
3120 7582 7986 95110
* Based on extreme climates where outdoor humidity is 7090% RH. For less extreme climates, larger
homes can be adequately served with less capacity. Actual requirements may vary.
Airflow versus external static pressure
(01” water pressure) with collars
attached
0” 160 CFM
0.2” 140 CFM
0.4” 120 CFM
0.6” 100 CFM
M29763
28-1/2 (724)
12 (305)
12
(305)
8 INCH (203)
DIAMETER
DR65A3000 Dehumidification System 33-00297EFS—07
4