Wiring Diagram
Table Of Contents
- Wiring Diagrams
- Heat only: Gas or Oil Furnace
- Cool only
- 1H/1C: Gas Furnace
- 2H/1C: Gas Furnace
- 2 Transformer System, 1H/1C: Oil Furnace
- 2 Transformer System, Hot Water Heat with Air-Conditioning (or Hot Water Coil)
- Hot Water Boiler, Heat Only
- Hot Water Heat with Power Open Zone Valve
- 2H/2C: Gas Furnace
- 1H/1C: Heat Pump without Aux Heat
- 2H/1C: Heat Pump with Electric Aux Heat
- 2H/2C: Heat Pump without Aux Heat
- 3H/2C Heat Pump with Electric Aux Heat
- Dual Fuel, 2H/1C: Heat Pump
- Dual Fuel, 3H/2C: Heat Pump
- Whole house humidifier, dehumidifier, or ventilator
T10 PRO WI-FI WIRING DIAGRAMS
33-00439ā02 6
Dual Fuel, 3H/2C: Heat Pump
M36911A
DUAL FUEL
3H/2C HEAT PUMP
COMPATIBLE T6 MODELS:
TH6320WF2003
1
COMMON REQUIRED.
L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
THE HEAT PUMP AND FURNACE HAVE SEPARATE BOARDS. WE SHOW
THEM TOGETHER TO SIMPLIFY THE DIAGRAM. W IS FROM THE
FURNACE BOARD.
LOCKOUT OF AUX HEAT ON HIGH OUTDOOR TEMPERATURE CAN BE
DONE THROUGH ROUTER/INTERNET CONNECTION AND HOME APP OR
WIRE C7089U1006 TO THE TWO āSā TERMINALS.
DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS!
THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
S
S
Y
Y2
G
C
U
U
A
W2
W
K
Rc
R
L/A
E
AUX
FURNACE/
HEAT PUMP
R/Rc
SWITCH UP
O/B
1
2
3
4
5
6
3
4
6
5
R
W
L
Y
G
O
C
Y2
2