User's Manual
FlexLine Installation
22
4.10 Installing the compound glands, conduits and
stopping plugs without SmartConn
Depending on local regulations this device can be cabled by using compound
glands, direct entry or conduits.
4.10.1 Compound glands
Explosion proof (Ex-d) compound glands with an appropriate IP value must be used.
4.10.2 Conduits
Explosion proof (Ex-d) conduits with an appropriate IP value must be used. Refer to
the type plate on the device.
Warning!
Only use Ex-d certified materials of an appropriate IP value.
Warning!
Improper installation of cable glands, conduits or stopping plugs will
invalidate the Ex approval of the SmartRadar.
NOTE
Only for use in ATEX and IEC Ex approved installations.
NOTE
Install the compound glands according to the instructions provided
by the manufacturer.
Warning!
If the SmartRadar is installed in a hazardous area:
- Metal conduits must be used, size 3/4”.
- Stopper boxes must be installed within 45 cm (18”) of the device
to seal the cabling in the conduit.