4 - 10 Service Manual
TABLE 4-2 Primary Value (PV) items
Data Field
Max. Size
[characters]
Description
Primary Value 9 The measured value, e.g. +025.1277
PV identification 13 Quantity name, e.g.
x Product level
x Product temperature
x P1 pressure
PV units 5 Quantity unit, e.g.
x m
x kg/m
3
x kPa
PV type 3 Type can be:
x INN (innage)
x ULL (ullage)
x REL (relative)
x ABS (absolute)
PV health 9 Status of the Primary Value:
x UNCERTAIN
x BAD
PV representation 15 Representation of the PV:
x Manual
x Last valid
x Stored
x Instrument
x Environment
x Hardware
x Software
x Commission
x Calibration
x Operational
x No data
x No init.
x Killed
x Over range
x Under range
PV alarms 9 Alarm type that occurred:
x High High
x High
x Low
x Low Low
Tank identification 8 Tank name, e.g. CRUDE 07
Alive indicator 1 Blinking cursor (bottom right) indicates