User Manual
Commissioning
SmartRadar FlexLine Part No.: 4417.762_Rev07
6 - 142 Service Manual
6.10.3.2 Commissioning Parameters for MRT or RTD
See FIGURE 6-37 and FIGURE 6-38.
ESF07-0020
FIGURE 6-37 Resistance Temperature Detector (RTD) elements positions
Enraf Model VITO Type Description
MRT Multiple Resistance Thermometer MRT with up to 13 temperature elements with one spot
element
RTD 3-spot
Resistance Temperature Detector
1..3 RTD spots in a 3-wire connection
multi-spot
Resistance Temperature Detector
1..14 RTD spots in a 2-wire connection
lowest element offset
tank zero level
lowest element offset
must be +000.0000
(RTD 3-wire only)
RTD element positions
RTD element positions
RTD
3 spots
Multi
RTD probe