User Manual

Safety
Part No.: 4417.762_Rev07 SmartRadar FlexLine
Service Manual 2 - 7
NOTE: The radiated output power of the device is far below
the exposure limits. Nevertheless, use the device in
such a manner that the potential for human contact
during normal operation is minimal.
2.9.4 EN302372-1 ANNEX B
The following installation requirements shall be fulfilled:
1. SmartRadar FlexLine instruments are required to be installed at a
permanent fixed position at a closed (not open) metallic tank or rein-
forced concrete tank, or similar enclosure structure made of
comparable attenuating material.
2. Flanges and attachments of the radar equipment shall provide the
necessary microwave sealing by design.
3. Sight glasses shall be coated with a microwave proof coating when
necessary (i.e. electrically conductive coating).
4. Manholes or connection flanges at the tank shall be closed to ensure
a low-level leakage of the signal into the air outside the tank.
5. Whenever possible, mounting of the radar equipment shall be on top
of the tank structure with the orientation of the radar antenna to
pointing in a downward direction.
WARNING! Do not rub the radio antenna to prevent sparks.
6. Installation and maintenance of the radar equipment shall be
performed by professionally trained individuals only.
2.9.5 Low-Voltage Directive
The device is suitable for:
Pollution degree 2
Overvoltage category II
Class I equipment
CAUTION Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
2.9.3.3 IC (Industry Canada)
Industry Canada Statement:
This device complies with RSS-210 of the Industry Canada Rules. Operation is subject
to the following two conditions: 1) this device may not cause interference and 2) this
device must accept any interference, including interference that may cause undesired
operation of the device.
This class B digital apparatus complies with Canadian ICES-003
Cet appareil est conforme à la norme CNR-210 des règlements d'Industrie Canada. Son
fonctionnement est sujet aux deux conditions suivantes: 1) Cet appareil ne doit pas
provoquer d'interférences et 2) Cet appareil doit accepter toutes les interférences, y
compris celles pouvant entraîner son dysfonctionnement.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
NOTE: This device is certified to measure liquid levels in
metal, concrete or similar materials, enclosed tanks
NOTE: The radiated output power of the device is far below
the exposure limits. Nevertheless, use the device in
such a manner that the potential for human contact
during normal operation is minimal..
2.9.4 EN302372-1 ANNEX B
The following installation requirements shall be fulfilled:
1. SmartRadar FlexLine instruments are required to be installed at a
permanent fixed position at a closed (not open) metallic tank or
reinforced concrete tank, or similar enclosure structure made of
comparable attenuating material.
2. Flanges and attachments of the radar equipment shall provide the
necessary microwave sealing by design.
3. Sight glasses shall be coated with a microwave proof coating when
necessary (i.e. electrically conductive coating).
4. Manholes or connection flanges at the tank shall be closed to ensure
a low-level leakage of the signal into the air outside the tank.
5. Whenever possible, mounting of the radar equipment shall be on top
of the tank structure with the orientation of the radar antenna to
pointing in a downward direction.
WARNING! Do not rub the radio antenna to prevent sparks.
6. Installation and maintenance of the radar equipment shall be
performed by professionally trained individuals only.
2.9.5 Low-Voltage Directive
The device is suitable for:
Pollution degree 2
Overvoltage category II
Class I equipment