User Manual

Commissioning
Part No.: 4417.762_Rev07 SmartRadar FlexLine
Service Manual 6 - 75
FIGURE 6-13 Radar zero point and verification pins positions
In normal (product measuring) position (see FIGURE 6-14), the E-field
(electrical field of the microwave) is located perpendicular to the
direction of the verification pins. In this position, the verification pins are
less visible to the SmartRadar FlexLine.
FIGURE 6-14 Product measuring position
In verification pin measuring position (see FIGURE 6-15), the E-field
should be in parallel with the verification pin direction. Then the