Instructions
Table Of Contents
- Xenon™ XP 195X Series User Guide
- Disclaimer, Copyright, Trademarks & Patents
- Customer Support
- Table of Contents
- Get Started
- Program the Interface
- Introduction
- Program the Interface - Plug and Play
- Keyboard Wedge
- Laptop Direct Connect
- RS232 Serial Port
- RS485
- USB IBM SurePos
- USB PC or Macintosh Keyboard
- USB HID
- USB Serial
- Verifone® Ruby Terminal
- Gilbarco® Terminal
- Honeywell Bioptic Aux Port
- Datalogic™ Magellan® Aux Port
- Wincor Nixdorf Terminal
- Wincor Nixdorf Beetle™ Terminal
- Wincor Nixdorf RS232 Mode A
- Keyboard Country Layout
- Keyboard Wedge Modifiers
- Keyboard Style
- Keyboard Conversion
- Control Character Output
- Keyboard Modifiers
- RS232 Modifiers
- Scanner to Bioptic Communication
- Cordless System Operation
- How the Cordless Charge Base/Access Point Works
- Link the Scanner to a Charge Base
- Link the Scanner to an Access Point
- Replace a Linked Scanner
- Communication Between the Cordless System and the Host
- Program the Scanner and Base or Access Point
- RF (Radio Frequency) Module Operation
- System Conditions
- Page Button
- Page Button and Presentation Modes
- Charge Information
- Battery Information for the Xenon XP 1952g/1952h
- Instant Charge Pack Information for the Xenon XP 1952g-BF/Xenon XP 1952h-BF
- Beeper and LED Sequences and Meaning
- Low Power Alerts
- Reset Scanner
- Scan While in Base Cradle
- Base Charge Modes
- Page
- Error Indicators
- Scanner Report
- Scanner Address
- Base or Access Point Address
- Scanner Modes
- Unlink the Scanner
- Out-of-Range Alarm
- Scanner Power Time-Out Timer
- Flexible Power Management
- Batch Mode
- Multiple Scanner Operation
- Scanner Name
- Application Work Groups
- Reset the Factory Defaults: All Application Work Groups
- Reset the Custom Defaults: All Application Work Groups
- Use the Scanner with Bluetooth Devices
- Minimize Bluetooth/ISM Band Network Activity
- Host Acknowledgment
- Input/Output Settings
- Power Up Beeper
- Beep on BEL Character
- Trigger Click
- Good Read and Error Indicators
- Trigger Modes
- Presentation Mode
- In-Stand Sensor Mode
- Poor Quality Codes
- CodeGate™
- Streaming Presentation™ Mode
- Hands Free Time-Out
- Reread Delay
- Character Activation
- Character Deactivation
- Illumination Lights
- Aimer Delay
- Aimer Mode
- Centering
- Preferred Symbology
- Output Sequence Overview
- Output Sequence Editor Commands
- Enter Output Sequence
- Multiple Symbols
- No Read
- Video Reverse
- Working Orientation
- Healthcare Settings
- Data Edit
- Data Format
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- Coupon GS1 DataBar Output
- UPC-E0
- UPC-E1
- EAN/JAN-13
- EAN/JAN-8
- MSI
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- Codablock A
- Codablock F
- Label Code
- PDF417
- MacroPDF417
- MicroPDF417
- GS1 Composite Codes
- GS1 Emulation
- TCIF Linked Code 39 (TLC39)
- QR Code
- DotCode
- Digimarc Barcode™
- Data Matrix
- MaxiCode
- Aztec Code
- Chinese Sensible (Han Xin) Code
- Postal Codes - 2D
- Postal Codes - Linear
- Imaging Commands
- Single-Use Basis
- Command Syntax
- Image Snap - IMGSNP
- Image Ship - IMGSHP
- IMGSHP Modifiers
- A - Infinity Filter
- C - Compensation
- D - Pixel Depth
- E - Edge Sharpen
- F - File Format
- H - Histogram Stretch
- I - Invert Image
- IF- Noise Reduction
- IR - Image Rotate
- J - JPEG Image Quality
- K - Gamma Correction
- L, R, T, B, M - Image Cropping
- P - Protocol
- S - Pixel Ship
- U - Document Image Filter
- V - Blur Image
- W - Histogram Ship
- Image Size Compatibility
- IMGSHP Modifiers
- Intelligent Signature Capture - IMGBOX
- RF Default Imaging Device
- Utilities
- Serial Programming Commands
- Product Specifications
- Xenon XP 1950g/1950h Corded Scanner Product Specifications
- Xenon XP 1952g/1952h Cordless Scanner Product Specifications
- Xenon XP 1952g-BF/1952h-BF Scanner Product Specifications
- CCB01-010BT/CCB01-010BT-BF Charge Base Product Specifications
- CCB-H-010BT/CCB-H-010BT-BF Charge Base Product Specifications
- Depth of Field Charts
- Standard Connector Pinouts
- Required Safety Labels
- Maintenance and Troubleshooting
- Reference Charts
- XEN195X-EN-UG-01 Rev E, 7/20
Xenon XP User Guide 107
1. If you are using barcodes to create your output sequence, scan Enter Output
Sequence on page 110.
2. Code I.D.
On the Symbology Charts on page 297, find the symbology to which you want
to apply the output sequence format. Make a note of the hex value for that
symbology. If you are using barcodes to create your output sequence, scan the
2 digit hex value from the Programming Chart, beginning on page 311.
3. Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Make a note of the length. If you are using barcodes to
create your output sequence, scan the 4 digit data length Programming Chart,
beginning on page 311. (Note: 50 characters is entered as 0050. 9999 is a
universal number, indicating all lengths.) When calculating the length, you
must count any programmed prefixes, suffixes, or formatted characters as part
of the length (unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page 300, find the hex value
that represents the character(s) you want to match. Make a note of the hex
value for the character(s). If you are using barcodes to create your output
sequence, use the Programming Chart, beginning on page 311 to read the
alphanumeric combination that represents the ASCII characters. (99 is the
universal number, indicating all characters.)
5. End Output Sequence Editor
Use FF to terminate this string or to begin another output sequence. If you are
using barcodes, scan F F. Scan Save to save your entries.
Other Programming Selections
If you are creating an output sequence using barcodes, scan Discard (page 312) to
exit without saving any output sequence changes.
Output Sequence Editor Commands
SEQBLKSequence editor start command.
SEQPREAdd prefix to complete output sequences.
SEQSUF Add suffix to complete output sequences.
SEQSEP Add separators to complete output sequences.
SEQTTS1 Transmit partial sequence.
SEQSAT Define satisfactory subsets of full output sequence.
SEQTIM Timeout for sequence members when using SEQSAT.
SEQIPRAdd prefix to partial output sequences.