Use and Care Manual
69
STORAGE
Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month No preparation required.
1 month to 1 year Fill with fresh gasoline and add gasoline
stabilizer*.
1 year or more Fill with fresh gasoline and add gasoline
stabilizer*.
Remove the spark plug. Put a teaspoon of
engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil (see page 56).
After removal from storage, drain the stored
gasoline into a suitable container, and fill with
fresh gasoline before starting.
*
Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacturer’s instructions for use.
Contact your authorized Honda generator dealer for stabilizer
recommendations.