Owner’s Manual GENERATOR EU7000is See page 94 for instructions on assembling your generator. See page 99 for Initial Use Instructions. 31Z37616 00X31-Z37-6160 PANTONE 186C K 背幅4.6mm AH 英 FM Hi Printed in India C 2019 Honda Motor Co., Ltd.
31Z376160.book 0 ページ 2019年2月8日 金曜日 午後2時2分 31Z376160.book 99 ページ 2019年2月8日 金曜日 午後2時2分 QUICK REFERENCE INFORMATION Fuel The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. Engine Oil Spark Plug Maintenance Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.
1Z376160.book 1 ページ 2019年2月8日 金曜日 午後2時2分 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
31Z376160.book 2 ページ 2019年2月8日 金曜日 午後2時2分 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
31Z376160.book 3 ページ 2019年2月8日 金曜日 午後2時2分 CONTENTS GENERATOR SAFETY ...............................................................................6 IMPORTANT SAFETY INFORMATION .................................................6 Operator Responsibility.....................................................................6 Carbon Monoxide Hazards................................................................6 Electric Shock Hazards ......................................................................
31Z376160.book 4 ページ 2019年2月8日 金曜日 午後2時2分 CONTENTS GFCI OPERATION CHECK ...................................................................35 AC OPERATION....................................................................................38 AC Applications................................................................................40 AC Receptacle Selection..................................................................41 Power Producing Circuits....................................................
31Z376160.book 5 ページ 2019年2月8日 金曜日 午後2時2分 CONTENTS TAKING CARE OF UNEXPECTED PROBLEMS ......................................74 ENGINE WILL NOT START..................................................................74 ENGINE LACKS POWER......................................................................75 NO POWER AT THE AC RECEPTACLES.............................................75 TECHNICAL INFORMATION ...................................................................76 Serial Number Location ......
31Z376160.book 6 ページ 2019年2月8日 金曜日 午後2時2分 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all of the instructions in this manual and on the generator.
31Z376160.book 7 ページ 2019年2月8日 金曜日 午後2時2分 GENERATOR SAFETY Electric Shock Hazards • The generator produces enough electric power to cause a serious shock or electrocution if misused. • Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.
31Z376160.book 8 ページ 2019年2月8日 金曜日 午後2時2分 GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Do not refuel during operation. Allow the engine to cool if it has been in operation. Refuel only outdoors in a well-ventilated area and on a level surface. Never smoke near gasoline, and keep other flames and sparks away. Do not overfill the fuel tank. Make sure that any spilled fuel has been wiped up and cleaned before starting the engine.
31Z376160.book 9 ページ 2019年2月8日 金曜日 午後2時2分 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
31Z376160.book 10 ページ 2019年2月8日 金曜日 午後2時2分 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls.
31Z376160.
31Z376160.book 12 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES CONTROLS MAIN Switch The MAIN switch controls the ignition system. OFF OFF – Stops the engine. The main switch key can be removed/ inserted. ON – Running position, and for starting with the ENGINE START button or recoil starter, and for using the remote control kit (optional parts). ON MAIN SWITCH ENGINE START Button With the MAIN switch in the ON position, press and release the ENGINE START button to start the engine.
31Z376160.book 13 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Starter Grip Used when the battery voltage is too low to turn the starter motor. Pulling the starter grip operates the recoil starter to start the engine. STARTER GRIP 20° • Do not exceed 20 degrees from horizontal when pulling the starter grip. • Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.
31Z376160.book 14 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Parallel Operation Outlets These outlets are used for connecting the EU7000is to another EU7000is generator for parallel operation (see page 43). A Honda approved parallel kit (optional equipment) is required for parallel operation. This kit can be purchased from an authorized Honda generator dealer. PARALLEL OPERATION OUTLETS Voltage Selector Switch Select the voltage before starting the engine.
31Z376160.book 15 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES AC Circuit Protectors The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.
31Z376160.book 16 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Ground Fault Circuit Interrupter (GFCI) Receptacle Each 120 V 20 A duplex receptacle is protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground fault currents.
31Z376160.book 17 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Folding Handle The foldable handle makes the generator easy to push and should be folded when the generator is stationary. Do not rest objects on the extended handle. To Extend The Handle Lift handle upward. Lock levers will lock and secure the handle into place. To Fold The Handle 1. Press both handle lock levers downward. 2. Lower the handle.
31Z376160.book 18 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Maintenance Covers Open and close the maintenance cover for maintenance of the EU7000is. Open the right maintenance cover, to use the recoil starter when the battery is discharged. Be sure the maintenance cover is closed while the generator is running. Running the generator with maintenance cover(s) open will adversely affect the engine performance, and will cause the generator to overheat.
31Z376160.book 19 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES FEATURES Ground Terminal The ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
31Z376160.book 20 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES OUTPUT Indicator The green OUTPUT indicator is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR (GREEN) OVERLOAD ALARM (Indicator) If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the red OVERLOAD indicator will come ON.
31Z376160.book 21 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES OIL ALERT®/CHECK Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the OIL ALERT/CHECK indicator comes ON, and the Oil Alert system will automatically stop the engine (the MAIN switch will remain in the ON position).
31Z376160.book 22 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES i-Monitor™ The i-Monitor is a user interface that allows the operator to view (when the generator is running) total operating time in hours, generator output, engine RPM, battery voltage, and error messages. The different display modes are selected by pressing the i-Monitor button. i-Monitor at Startup During start up, the i-Monitor display and all three indicators will simultaneously blink once.
31Z376160.book 23 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES i-Monitor Display Mode 2 – Power Output This mode displays an approximate generator output on the display screen. The output is expressed in VA (volt-amperes). The output value is not an exact measurement and should be regarded as a reference only. Power output will not display until a load is connected to the generator.
31Z376160.book 24 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES i-Monitor Low Battery Message If the ENGINE START button is pressed and ‘‘batt’’ is shown on the iMonitor display, the battery voltage is too low to operate the engine’s electric starter. Use the recoil starter to start the generator. Have the battery recharged and checked (see page 66). i-Monitor System Error Messages If the generator has a system malfunction, it will show an error message on the i-Monitor display.
31Z376160.book 25 ページ 2019年2月8日 金曜日 午後2時2分 CONTROL & FEATURES Fuel Gauge The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty. To provide increased operating time, start with a full tank before operation. Check the fuel level with the generator on a level surface. Always refuel with the engine OFF and cool.
31Z376160.book 26 ページ 2019年2月8日 金曜日 午後2時2分 BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
31Z376160.book 27 ページ 2019年2月8日 金曜日 午後2時2分 BEFORE OPERATION Check the Engine • Before each use, look around and underneath the engine for signs of oil or gasoline leaks. • Check the engine oil level (see page 55). A low engine oil level will cause the Oil Alert system to shut down the engine. • Check the air filters (see page 58). Dirty air filters will restrict air flow to the fuel system, reducing engine and generator performance. • Check the fuel level (see page 53).
31Z376160.book 28 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 26). For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
Z376160.book 29 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION Frequency of Use If your generator will be used on an infrequent or intermittent basis, (more than 4 weeks before next use), please refer to the Battery Service section of the SERVICING YOUR GENERATOR (see page 63) and the Fuel section of the STORAGE chapter (see page 68) for additional information regarding battery and fuel deterioration.
31Z376160.book 30 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION 3. Make sure the Eco Throttle switch is in the OFF position, or more time will be required for warm-up. If you wish to use the Eco Throttle system, turn the Eco Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes. 4. Turn the MAIN switch to the ON position. ECO THROTTLE SWITCH OFF ON OFF 5. Press and release the ENGINE START button. The ENGINE START button functions for 5 seconds.
31Z376160.book 31 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION • Use the recoil starter when the battery voltage is too low to turn the starter motor. OFF a. Turn the MAIN switch to the ON position. ON b. Open the right maintenance cover by turning its latch counterclockwise. c. Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. MAIN SWITCH STARTER GRIP • Do not exceed 20 degrees from horizontal when pulling the starter grip.
31Z376160.book 32 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the MAIN switch to the OFF position. Under normal conditions, use the following procedure. 1. Turn the MAIN switch to the OFF position. OFF ON MAIN SWITCH 2. Unplug all appliances from the generator AC receptacles. 3.
31Z376160.book 33 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION STARTING THE ENGINE with REMOTE CONTROL (Optional part) 1. Determine the voltage requirements and adjust the voltage selector switch, as needed. 2. Turn the MAIN switch of the generator to the ON position. OFF ON MAIN SWITCH 3. Turn the MAIN switch of the remote control to the ON position. 4. Press and release the ENGINE START button. The ENGINE START button functions for 5 seconds.
31Z376160.book 34 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION STOPPING THE ENGINE with REMOTE CONTROL (Optional part) 1. Turn the MAIN switch of the remote control to the OFF position.
31Z376160.book 35 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION GFCI OPERATION CHECK Always check GFCI operation before using the generator. A faulty GFCI system will not provide proper protection against electric shock as designed. An electric shock can result in serious injury or death. Always perform the GFCI system inspection before using the generator. If the GFCI system fails the test, the generator must be repaired by an authorized Honda servicing dealer before use.
31Z376160.book 36 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION 1. Unplug all tools and appliances from the generator. 2. Start the engine (see page 29). When the GFCI is operating normally, the indicator will continuously light green. Light order: (red) Blink once (green) Light once (red) Blink once (green) Lights continuously • If the green indicator does not come on, press the RESET button. • If the red indicator starts to blink continuously, contact an authorized Honda generator dealer. 3.
31Z376160.book 37 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION 4. Press the RESET button: • The green indicator will light continuously. • If the red indicator starts to blink continuously, contact an authorized Honda generator dealer. INDICATOR RESET BUTTON When the RESET button pops out or the green indicator does not light during operation: • Unplug all appliances from the GFCI protected receptacle. • Press the RESET button. – If the GFCI cannot be reset, the GFCI is faulty.
31Z376160.book 38 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION AC OPERATION If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded. Substantial overloading that continuously lights the red OVERLOAD indicator may damage the generator.
31Z376160.book 39 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION 3. Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. PLUG 4. Turn on the appliance. If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the red OVERLOAD indicator will come ON.
31Z376160.book 40 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded.
31Z376160.book 41 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION AC Receptacle Selection The control panel, shown below, has a voltage selector switch and four receptacles. Receptacle 4, the 240-volt receptacle, has two powered terminals, 4A and 4B.
31Z376160.book 42 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION Voltage Selector Switch Disconnect or turn OFF all appliances or tools connected to the generator before changing the voltage selector switch position. The generator may be damaged if the switch position is changed with loads connected and operating. The power available to each receptacle depends on the position of the voltage selector switch.
31Z376160.book 43 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION AC PARALLEL OPERATION Before connecting an appliance to either generator, make sure that the appliance is in good working order and that its electrical rating does not exceed that of the receptacle. Most motorized appliances require more than their electrical rating for startup. When an electric motor is started, the OVERLOAD indicator (red) may come ON. This is normal if the OVERLOAD indicator (red) goes OFF within 5 seconds.
31Z376160.book 44 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION 3. Start the engine on each generator and make sure each OUTPUT indicator (green) comes ON. 4. Turn the AC circuit protector of the parallel operation box ON. AC CIRCUIT PROTECTORS RECEPTACLE 5. Plug in the appliance following the instructions provided with the parallel kit. 6. Turn on the appliance. If the generators are overloaded (see page 46), or if there is a short circuit in a connected appliance, the OVERLOAD indicators (red) will come ON.
31Z376160.book 45 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION AC Parallel Operation Applications Two EU7000is generators can be connected together to increase the available power using a parallel kit (optional equipment). Follow the instructions included with the parallel kit. Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock.
31Z376160.book 46 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION Most appliance motors require more than their rated wattage for startup. Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator. Maximum power in parallel operation is: 12.0 kVA For continuous operation, do not exceed the rated power. Rated power in parallel operation is: 11.0 kVA In either case, the total power requirements (VA) of all appliances connected must be considered.
31Z376160.book 47 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION ECO THROTTLE® SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco Throttle system does not operate.
31Z376160.book 48 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building’s electrical system can allow current from the generator to backfeed into the utility lines.
31Z376160.book 49 ページ 2019年2月8日 金曜日 午後2時2分 OPERATION Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. • In some areas, generators are required to be registered with local utility companies.
31Z376160.book 50 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
31Z376160.book 51 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Improper maintenance can cause an unsafe condition. Failure to properly follow maintenance instructions and precautions can cause serious injuries or death.
31Z376160.book 52 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) ITEM Perform at every indicated month or operating hour interval, whichever comes first.
31Z376160.book 53 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR REFUELING With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. Fuel can damage paint and plastic.
31Z376160.book 54 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR FUEL TANK CAP TETHER FULL EMPTY FUEL STRAINER FUEL GAUGE UPPER LEVEL MARK (RED) After refueling, reinstall the fuel tank cap securely. FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Use unleaded gasoline only, or the catalyzer will loose its effectiveness and negatively affect exhaust emissions.
31Z376160.book 55 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the engine stopped and in a level position. 1. Open the right maintenance cover by turning its latch counterclockwise. 2. Remove the oil filler cap. 3. Check the oil level. If it is below the upper limit, fill with the recommended oil (see page 57) to the upper limit of the oil filler neck. 4. Reinstall the oil filler cap securely. 5.
31Z376160.book 56 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Open the right maintenance cover by turning its latch counterclockwise. 2. Reach under the generator and remove the black rubber seal located below the oil drain plug. 3. Place a suitable container underneath the generator to catch the used oil. 4. Remove the oil filler cap. 5.
31Z376160.book 57 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W–30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range. AMBIENT TEMPERATURE The SAE oil viscosity and service category are in the API label on the oil container.
31Z376160.book 58 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR AIR CLEANER SERVICE 1. Open the left maintenance cover by turning its latch counterclockwise. 2. Unsnap the air cleaner cover clips; remove the air cleaner cover. CLIP PAPER AIR FILTER GUIDE FOAM AIR FILTER AIR CLEANER COVER 3. Foam air filter: a. Remove the foam air filter from the air cleaner cover. b. Check the foam air filter to be sure it is clean and in good condition.
31Z376160.book 59 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the fuel system, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule. 1. Clean the foam air filter in warm soapy water, rinse, and allow to dry thoroughly, or clean in non-flammable solvent and allow to dry. 2.
31Z376160.book 60 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plug: BPR6ES (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine is hot, allow it to cool before servicing the spark plug. 1.
31Z376160.book 61 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR 5. Inspect the spark plug. Replace it if the electrode is worn or fouled, or if the insulator is cracked or chipped. SIDE ELECTRODE 6. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. 0.028–0.031 in (0.7–0.8 mm) SEALING WASHER INSULATOR The gap should be: 0.028–0.031 in (0.7–0.8 mm) 7.
31Z376160.book 62 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. 1. Remove the two 5×16 mm pan head screws, and remove the tail pipe and spark arrester. SPARK ARRESTER TAIL PIPE 5×16 mm PAN HEAD SCREW (2) 2.
31Z376160.book 63 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR BATTERY SERVICE Your generator’s engine charging system charges the battery while the engine is running. However, if the generator is only used periodically, the battery must be charged monthly to maintain the battery service life. The battery contains sulfuric acid (electrolyte), which is highly corrosive and poisonous. Getting electrolyte in your eyes or on your skin can cause serious burns.
31Z376160.book 64 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR Battery Removal WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds. Wash hands after handling. 1. Lift the handle upward. The lock levers will lock and secure the handle in place. HANDLE HANDLE LOCK LEVER 2. Loosen the cover screw and remove the battery maintenance cover.
31Z376160.book 65 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR 3. Remove the negative (–) cable from the battery negative (–) terminal, and then remove the positive (+) cable from the battery positive (+) terminal. 4. Unhook the battery strap from the bottom hook of the generator. BATTERY STRAP NEGATIVE (–) CABLE POSITIVE (+) CABLE 5. Remove the battery from the battery tray.
31Z376160.book 66 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR Battery Charging The battery gives off explosive hydrogen gas during normal operation. A spark or flame can cause the battery to explode with enough force to kill or seriously hurt you. Wear protective clothing and a face shield, or have a skilled mechanic perform the battery maintenance. The battery is rated at 11.2 Ah (ampere-hours). Charging current should equal 10% of the battery’s ampere-hour rating.
31Z376160.book 67 ページ 2019年2月8日 金曜日 午後2時2分 SERVICING YOUR GENERATOR FUSE If the fuse is blown, the starter motor won’t operate. In the event of fuse failure, locate the cause of failure and repair it before you continue operation. If the fuse continues to fail, discontinue generator use and consult an authorized Honda generator dealer. 1. Turn the MAIN switch to the OFF position and remove the key before checking or replacing the fuse. 2. Loosen the cover screw and remove the battery maintenance cover.
31Z376160.book 68 ページ 2019年2月8日 金曜日 午後2時2分 STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
31Z376160.book 69 ページ 2019年2月8日 金曜日 午後2時2分 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required. 1 month to 1 year Fill with fresh gasoline and add gasoline stabilizer*. 1 year or more Fill with fresh gasoline and add gasoline stabilizer*. Remove the spark plug. Put a teaspoon of engine oil into the cylinder. Turn the engine slowly with the pull rope to distribute the oil. Reinstall the spark plug.
31Z376160.book 70 ページ 2019年2月8日 金曜日 午後2時2分 STORAGE Draining the Fuel Tank Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. • Handle fuel only outdoors. • Wipe up spills immediately. Unscrew the fuel tank cap, remove the fuel strainer, and empty the fuel tank into an approved gasoline container.
31Z376160.book 71 ページ 2019年2月8日 金曜日 午後2時2分 STORAGE Engine Oil Change the engine oil (see page 56). Engine Cylinder 1. Remove the spark plug (see page 60). 2. Pour a teaspoon (5 cc) of clean engine oil into the cylinder. 3. Pull the starter rope several times to distribute the oil in the cylinder. 4. Reinstall the spark plug (see page 60). 5. Slowly pull the starter grip until resistance is felt.
31Z376160.book 72 ページ 2019年2月8日 金曜日 午後2時2分 STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
31Z376160.book 73 ページ 2019年2月8日 金曜日 午後2時2分 TRANSPORTING If the generator has been running, allow the engine to cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some materials. Keep the generator level when transporting to reduce the possibility of fuel leakage. When using ropes or tie-down straps to secure the generator for transportation, be sure to only use the frame bars as attachment points.
31Z376160.book 74 ページ 2019年2月8日 金曜日 午後2時2分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause MAIN switch is in the OFF position. Out of fuel. Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Low engine oil level caused Oil Alert to stop engine. Correction Turn MAIN switch to the ON position (see page 30). Refuel (see page 53). Drain fuel tank (see page 70). Refuel with fresh gasoline (see page 53).
31Z376160.book 75 ページ 2019年2月8日 金曜日 午後2時2分 TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible Cause Air filter restricted. Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Correction Clean or replace air filter (see pages 58, 59). Drain fuel tank (see page 70). Refuel with fresh gasoline (see page 53).
31Z376160.book 76 ページ 2019年2月8日 金曜日 午後2時2分 TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries.
31Z376160.book 77 ページ 2019年2月8日 金曜日 午後2時2分 TECHNICAL INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
31Z376160.book 78 ページ 2019年2月8日 金曜日 午後2時2分 TECHNICAL INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. • Hard starting or stalling after starting. • Rough idle. • Engine speed instability. • Misfiring or backfiring under load. • Afterburning (backfiring). • Black exhaust smoke or high fuel consumption.
31Z376160.book 79 ページ 2019年2月8日 金曜日 午後2時2分 TECHNICAL INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
31Z376160.book 80 ページ 2019年2月8日 金曜日 午後2時2分 TECHNICAL INFORMATION Specifications Dimensions Model / Type Description code Length [Handle in up position] Width Height Dry mass [weight]* * With battery EU7000isN / AT1 EEJD 33.4 in (848 mm) [47.2 in (1,198 mm)] 27.6 in (700 mm) 28.4 in (721 mm) 261.5 lbs (118.6 kg) Engine Model Engine type Displacement [Bore×Stroke] Compression ratio Engine speed GX390T2 4-stroke, overhead valve, single cylinder 23.7 cu-in (389 cm3) [3.5×2.5 in (88×64 mm)] 8.
31Z376160.
31Z376160.book 82 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or visit http://powerequipment.honda.
31Z376160.book 83 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help. Almost all problems are solved in this way.
31Z376160.book 84 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Distributor’s Limited Warranty This warranty is limited to the following Honda Power Equipment products when distributed by American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi Drive, Alpharetta, Georgia 30005-8847. The following warranty applies to products purchased at retail or placed in rental service on or after January 1, 2010.
31Z376160.book 85 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that product, during the dealer’s normal business hours.
31Z376160.book 86 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Exclusions: 1.
31Z376160.book 87 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Honda Accessories, Replacement Parts, And Apparel This warranty is limited to Honda Power Equipment parts, accessories, and apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia 30005-8847.
31Z376160.book 88 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment accessory, replacement part, apparel, or the Honda Power Equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer, distributor, or distributor’s dealer in the United States, Puerto Rico, or the U.S.
31Z376160.book 89 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California (models certified for sale in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States and its territories. Honda Canada Inc.
31Z376160.book 90 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Owner’s Warranty Responsibility As the power equipment engine owner, you are responsible for completing all required maintenance listed in your owner’s manual. Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure that all scheduled maintenance has been completed.
31Z376160.book 91 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Warranty Coverage Honda power equipment engines sold in the United States and Canada are covered by this warranty for a period of two years from the date of delivery to the original retail purchaser or the length of the Honda Distributor’s Limited Warranty, whichever is longer. This warranty is transferable to each subsequent purchaser for the duration of the warranty period.
31Z376160.book 92 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION To Obtain Warranty Service You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours.
31Z376160.book 93 ページ 2019年2月8日 金曜日 午後2時2分 CONSUMER INFORMATION Disclaimer of Consequential Damage and Limitation of Implied Warranties American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment; and any implied warranties are limited to the duration of this written warranty.
31Z376160.book 94 ページ 2019年2月8日 金曜日 午後2時2分 ASSEMBLY SAFETY The Importance of Proper Assembly Proper assembly is essential to operator safety and the reliability of the machine. Any error or oversight made by the person assembling and servicing a unit can easily result in faulty operation, damage to the machine, or injury to the operator. Improper assembly can cause an unsafe condition. Failure to properly follow assembly procedures can lead to serious injury or death.
31Z376160.book 95 ページ 2019年2月8日 金曜日 午後2時2分 ASSEMBLY Important Safety Precautions • Make sure you have a clear understanding of all basic shop safety practices and that you are wearing appropriate clothing and safety equipment. When performing this assembly, be especially careful of the following: Read the instructions before you begin, and be sure you have the tools and skills required to perform the tasks safely. • Make sure the engine is off before you begin any assembly, maintenance, or repairs.
31Z376160.book 96 ページ 2019年2月8日 金曜日 午後2時2分 ASSEMBLY ASSEMBLY Unpacking 1. Remove the generator and loose parts box from the carton. 2. Compare the loose parts with the inventory list below. Tools Required: 12 mm wrench, 10 mm wrench or Phillips head screwdriver for battery connections, pliers (not included) Do not add fuel or oil before tipping the generator. Oil or fuel may damage the engine or your property. Loose Parts Check all loose parts against the following list. Ref. No.
31Z376160.book 97 ページ 2019年2月8日 金曜日 午後2時2分 ASSEMBLY Wheel Kit Installation Do not operate the generator without the wheel kit installed. The wheel kit provides air space between the ground and the generator air intake. If the wheel kit is not installed, it may be possible for dirt and debris to be drawn into the generator air intake, possibly causing generator damage. Always operate the generator with the wheel kit installed. 1.
31Z376160.book 98 ページ 2019年2月8日 金曜日 午後2時2分 ASSEMBLY Battery WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds. Wash hands after handling. The battery is disconnected and strapped into the battery tray for shipment. 1. Remove the battery maintenance cover (see page 64). 2. Remove the battery strap from the bottom hook, and then remove the battery. 3. Only remove the battery cables from the twist clip.
31Z376160.book 99 ページ 2019年2月8日 金曜日 午後2時2分 INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Open the right maintenance cover by turning its latch counterclockwise. 3. Remove the oil filler cap. 4. Add enough oil to bring the oil level to the upper limit of the oil filler neck. SAE 10W-30 API service category SJ or later (or equivalent) is recommended for general use; for additional recommendations (see page 57).
31Z376160.book 100 ページ 2019年2月8日 金曜日 午後2時2分 INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage. Wipe up spills immediately.
31Z376160.book 101 ページ 2019年2月8日 金曜日 午後2時2分 INITIAL USE INSTRUCTIONS 1. Remove the fuel tank cap. 2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (red) on the fuel filter. 3. After refueling, reinstall the fuel tank cap securely. FUEL TANK CAP TETHER FULL EMPTY FUEL STRAINER FUEL GAUGE UPPER LEVEL MARK (RED) Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank.
31Z376160.book 102 ページ 2019年2月8日 金曜日 午後2時2分 INITIAL USE INSTRUCTIONS BATTERY VOLTAGE Check the battery voltage with the i-Monitor (see page 23). The battery voltage should be 12.3 V or more. If the battery voltage is low, charge the battery until the battery voltage is 12.3 V or more.
31Z376160.book 103 ページ 2019年2月8日 金曜日 午後2時2分 OPTIONAL PARTS REMOTE CONTROL KIT 1. Remove the battery maintenance cover (see page 64). 2. Remove the plug from the connector. • Do not discard the plug. The plug should be installed back into the connector when the remote control kit is removed. PLUG 3. View the back of the battery maintenance cover and locate the knockout near the top center of the cover. Carefully remove the knockout.
31Z376160.book 104 ページ 2019年2月8日 金曜日 午後2時2分 OPTIONAL PARTS 4. Pass the remote control cable through the supplied wire grommet, and fit the grommet into the battery maintenance cover knockout. 5. Plug the remote control cable into the connector. 6. Install the battery maintenance cover and tighten the cover screw. REMOTE CONTROL CABLE REMOTE CONTROL CABLE GROMMET REMOTE CONTROL BOX BATTERY MAINTENANCE COVER 7.
31Z376160.book 105 ページ 2019年2月8日 金曜日 午後2時2分 OPTIONAL PARTS HANGER KIT Protect the fuel tank and frame pipe with the protector films during installation of the hanger. 1. Slide one end of the hanger under the frame pipe on the left side of the generator. 2. Slide the other end of the hanger under the frame pipe on the right side of the generator. PROTECTOR FILM (commercially available) HANGER 3.
31Z376160.book 106 ページ 2019年2月8日 金曜日 午後2時2分 INDEX A AC Applications .................................................................................. 40 AC Circuit Protectors .......................................................................... 15 AC OPERATION................................................................................... 38 AC PARALLEL OPERATION................................................................ 43 AC Parallel Operation Applications................................
31Z376160.book 107 ページ 2019年2月8日 金曜日 午後2時2分 INDEX E Eco Throttle Switch ............................................................................ 13 ECO THROTTLE SYSTEM................................................................... 47 Electric Shock Hazards ......................................................................... 7 Emission Control System Information.............................................. 77 Emission Control System Warranty..................................................
31Z376160.book 108 ページ 2019年2月8日 金曜日 午後2時2分 INDEX I i-Monitor.............................................................................................. 22 IMPORTANT SAFETY INFORMATION ................................................ 6 Important Safety Precautions ............................................................ 95 INITIAL USE INSTRUCTIONS ............................................................ 99 IS YOUR GENERATOR READY TO GO?............................................
31Z376160.book 109 ページ 2019年2月8日 金曜日 午後2時2分 INDEX R REFUELING ......................................................................................... 53 Refuel With Care ................................................................................... 8 REMOTE CONTROL KIT ................................................................... 103 REMOVAL FROM STORAGE.............................................................. 72 S SAFE OPERATING PRECAUTIONS.............................................
31Z376160.book 110 ページ 2019年2月8日 金曜日 午後2時2分 INDEX U Unpacking ........................................................................................... 96 V Voltage Selector Switch ............................................................... 14, 42 W Wheel Kit Installation ......................................................................... 97 Wiring Diagram...................................................................................
31Z376160.
31Z376160.
31Z376160.book 0 ページ 2019年2月8日 金曜日 午後2時2分 31Z376160.book 99 ページ 2019年2月8日 金曜日 午後2時2分 QUICK REFERENCE INFORMATION Fuel The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. Engine Oil Spark Plug Maintenance Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.
Owner’s Manual GENERATOR EU7000is See page 94 for instructions on assembling your generator. See page 99 for Initial Use Instructions. 31Z37616 00X31-Z37-6160 PANTONE 186C K 背幅4.6mm AH 英 FM Hi Printed in India C 2019 Honda Motor Co., Ltd.